Mae'r defnydd o ddŵr modur tanddwr trochi, rotor sy'n gwrthsefyll traul aloi llawes a aloi byrdwn ddisg design.More gwydn na (olew trochi dirwyn i ben, rotor dwyn modur), yn fwy amgylcheddol friendly.No gollyngiadau olew ar ôl methiant y pwmp, dim llygredd o dŵr yn dda, yn fwy diogel use.The grŵp impeller defnyddio cryfder uchel gwrth-tywod sy'n gwrthsefyll traul PC deunyddiau polymer cyfansawdd, dylunio hydrolig tri dimensiwn newydd, impeller fel y bo'r angen, seramig gwrth-tywod strwythur gwisgo ymwrthedd, lifft llawn, flow.Water-lenwi mawr gall modur blymio dyfnder o 300 metr.
This product is a three-phase AC 380V (tolerance ± 5%), 50HZ (tolerance ± 1%) power supply system, designed for strict water quality requirements. The product is suitable for water temperature not higher than 20 °C, solid impurities content (mass ratio) is not greater than 0.01%, PH value (pH) between 6.5-8.5, hydrogen sulfide content is not greater than 1.5mg/L, chloride ion content is not greater than 400mg/L environment. This product is equipped with a closed or water-filled wet structure motor, before use must be submersible motor inner cavity filled with clean water to prevent false full, and then tighten the water and air bolts, otherwise not to use. The submersible pump must be completely immersed in water to work, penetration depth shall not exceed 70 meters, the distance from the bottom of the pump to the bottom of the well shall not be less than 3 meters. In addition, the well water flow should meet the continuous operation requirements of the submersible pump, the water output of the submersible pump should be controlled at 0.7-1.2 times the rated flow. When used, the well must be vertical, and the submersible pump can not be used horizontally or dumped, only vertical installation. To ensure safety, the submersible pump must match the cable according to the requirements and be equipped with external overload protection device, and it is strictly prohibited to conduct no-load test on the pump without water. This product is an ideal choice for providing high quality water source, and can be widely used in various industrial and civil water processing fields.
105QJ series water-filled stainless steel deep well pump |
|||||
Model |
Llif m³/h |
Pen (m) |
Modur Grym (KW) |
Uned diamedr (mm) |
diameter (mm) |
105QJ2-230/36 |
2 |
230 |
4kw |
103 |
105 |
105QJ2-300/50 |
300 |
5.5kw |
|||
105QJ2-390/65 |
390 |
7.5kw |
|||
105QJ4-50/10 |
4 |
50 |
1.1kw |
103 |
105 |
105QJ4-60/12 |
60 |
1.5kw |
|||
105QJ4-80/16 |
80 |
2.2kw |
|||
105QJ4-100/20 |
100 |
3kw |
|||
105QJ4-140/28 |
140 |
4kw |
|||
105QJ4-200/40 |
200 |
5.5kw |
|||
105QJ4-275/55 |
275 |
7.5kw |
|||
105QJ6-35/10 |
6 |
35 |
1.1kw |
103 |
105 |
105QJ6-40/12 |
40 |
1.5kw |
|||
105QJ6-60/16 |
60 |
2.2kw |
|||
105QJ6-75/20 |
75 |
3kw |
|||
105QJ6-105/28 |
105 |
4kw |
|||
105QJ6-140/40 |
140 |
5.5kw |
|||
105QJ6-192/55 |
192 |
7.5kw |
|||
105QJ8-25/5 |
8 |
25 |
1.1kw |
103 |
105 |
105QJ8-40/8 |
40 |
1.5kw |
|||
105QJ8-55/11 |
55 |
2.2kw |
|||
105QJ8-75/15 |
75 |
3kw |
|||
105QJ8-95/19 |
95 |
4kw |
|||
105QJ8-125/25 |
125 |
5.5kw |
|||
105QJ8-160/32 |
160 |
7.5kw |
|||
105QJ10-20/5 |
10 |
20 |
1.1kw |
103 |
105 |
105QJ10-30/8 |
30 |
1.5kw |
|||
105QJ10-40/11 |
40 |
2.2kw |
|||
105QJ10-55/15 |
55 |
3kw |
|||
105QJ10-75/19 |
75 |
4kw |
|||
105QJ10-90/25 |
90 |
5.5kw |
|||
105QJ10-120/32 |
120 |
7.5kw |
|||
105QJ16-22/9 |
16 |
22 |
2.2kw |
103 |
105 |
105QJ16-28/12 |
28 |
3kw |
|||
105QJ16-35/15 |
35 |
4kw |
|||
105QJ16-50/20 |
50 |
5.5kw |
|||
105QJ16-68/27 |
68 |
7.5kw |
130QJ series water-filled stainless steel deep well pump |
|||||
Model |
Llif m³/h |
Pen (m) |
Modur Grym (KW) |
Uned diamedr (mm) |
diameter (mm) |
130QJ10-60/7 |
10 |
60 |
1.5kw |
130 |
135 |
130QJ10-80/12 |
80 |
2.2kw |
|||
130QJ10-100/15 |
100 |
3kw |
|||
130QJ10-130/20 |
130 |
4kw |
|||
130QJ10-160/25 |
160 |
5.5kw |
|||
130QJ10-220/32 |
220 |
7.5kw |
|||
130QJ10-250/38 |
250 |
9.2kw |
|||
130QJ10-300/42 |
300 |
11kw |
|||
130QJ10-350/50 |
350 |
13kw |
|||
130QJ10-400/57 |
400 |
15kw |
|||
130QJ10-450/64 |
450 |
18.5kw |
|||
130QJ10-500/70 |
500 |
22kw |
|||
130QJ15-40/5 |
15 |
40 |
1.5kw |
130 |
135 |
130QJ15-50/7 |
50 |
2.2kw |
|||
130QJ15-60/10 |
60 |
3kw |
|||
130QJ15-80/12 |
80 |
4kw |
|||
130QJ15-105/15 |
105 |
5.5kw |
|||
130QJ15-150/22 |
150 |
7.5kw |
|||
130QJ15-170/25 |
170 |
9.2kw |
|||
130QJ15-200/28 |
200 |
11kw |
|||
130QJ15-240/34 |
240 |
13kw |
|||
130QJ15-280/40 |
280 |
15kw |
|||
130QJ15-300/42 |
300 |
18.5kw |
|||
130QJ15-336/48 |
336 |
18.5kw |
|||
130QJ15-350/50 |
350 |
22kw |
|||
130QJ15-400/56 |
400 |
22kw |
130QJ series water-filled stainless steel deep well pump |
|||||
Model |
Llif m³/h |
Pen (m) |
Modur Grym (KW) |
Uned diamedr (mm) |
diameter (mm) |
130QJ20-22/3 |
20 |
30 |
2.2kw |
130 |
135 |
130QJ20-30/5 |
42 |
3kw |
|||
130QJ20-42/6 |
54 |
4kw |
|||
130QJ20-52/8 |
65 |
5.5kw |
|||
130QJ20-72/11 |
85 |
7.5kw |
|||
130QJ20-90/14 |
110 |
9.2kw |
|||
130QJ20-105/16 |
128 |
11kw |
|||
130QJ20-130/19 |
145 |
13kw |
|||
130QJ20-150/22 |
164 |
15kw |
|||
130QJ20-182/27 |
182 |
18.5kw |
|||
130QJ20-208/31 |
208 |
22kw |
|||
130QJ20-240/35 |
240 |
25kw |
|||
130QJ20-286/42 |
286 |
30kw |
|||
130QJ25-35/6 |
25 |
35 |
3kw |
130 |
135 |
130QJ25-40/7 |
40 |
4kw |
|||
130QJ25-52/9 |
52 |
5.5kw |
|||
130QJ25-70/12 |
70 |
7.5kw |
|||
130QJ25-85/15 |
85 |
9.2kw |
|||
130QJ25-105/18 |
105 |
11kw |
|||
130QJ25-120/21 |
120 |
13kw |
|||
130QJ25-140/24 |
140 |
15kw |
150QJ series water-filled stainless steel deep well pump |
|||||
Model |
Llif m³/h |
Pen (m) |
Modur Grym (KW) |
Uned diamedr (mm) |
diameter (mm) |
150QJ12-40/3 |
12 |
40 |
2.2kw |
143 |
150 |
150QJ12-55/5 |
55 |
3kw |
|||
150QJ12-80/7 |
80 |
4kw |
|||
150QJ12-107/9 |
107 |
5.5kw |
|||
150QJ12-142/11 |
142 |
7.5kw |
|||
150QJ12-175/14 |
175 |
9.2kw |
|||
150QJ12-200/16 |
200 |
11kw |
|||
150QJ12-242/19 |
242 |
13kw |
|||
150QJ12-268/21 |
268 |
15kw |
|||
150QJ12-293/23 |
293 |
18.5kw |
|||
150QJ20-28/3 |
20 |
28 |
3kw |
143 |
150 |
150QJ20-48/5 |
48 |
4kw |
|||
150QJ20-70/7 |
70 |
5.5kw |
|||
150QJ20-90/9 |
90 |
7.5kw |
|||
150QJ20-107/11 |
107 |
9.2kw |
|||
150QJ20-135/14 |
135 |
11kw |
|||
150QJ20-155/16 |
155 |
13kw |
|||
150QJ20-175/18 |
175 |
15kw |
|||
150QJ20-195/20 |
195 |
18.5kw |
|||
150QJ20-220/22 |
220 |
18.5kw |
|||
150QJ20-235/25 |
235 |
22kw |
|||
150QJ20-255/28 |
255 |
25kw |
150QJ series water-filled stainless steel deep well pump |
|||||
Model |
Llif m³/h |
Pen (m) |
Modur Grym (KW) |
Uned diamedr (mm) |
diameter (mm) |
150QJ45-18/2 |
45 |
18 |
4KW |
143 |
150 |
150QJ45-28/3 |
28 |
5.5KW |
|||
150QJ45-46/5 |
46 |
7.5KW |
|||
150QJ45-57/6 |
57 |
9.2KW |
|||
150QJ45-65/7 |
65 |
11KW |
|||
150QJ45-75/8 |
75 |
13KW |
|||
150QJ45-90/10 |
90 |
15KW |
|||
150QJ45-108/12 |
108 |
18.5KW |
|||
150QJ45-125/14 |
125 |
22KW |
|||
150QJ45-145/16 |
145 |
25KW |
|||
150QJ45-168/18 |
168 |
30KW |
|||
150QJ32-20/2 |
32 |
20 |
3kw |
143 |
150 |
150QJ32-30/3 |
30 |
4kw |
|||
150QJ32-43/4 |
43 |
5.5kw |
|||
150QJ32-60/5 |
60 |
7.5kw |
|||
150QJ32-65/6 |
65 |
7.5kw |
|||
150QJ32-75/7 |
75 |
9.2kw |
|||
150QJ32-85/8 |
85 |
11kw |
|||
150QJ32-100/9 |
100 |
13kw |
|||
150QJ32-110/10 |
110 |
15kw |
|||
150QJ32-118/11 |
118 |
18.5kw |
|||
150QJ32-140/13 |
140 |
18.5kw |
|||
150QJ32-155/15 |
155 |
22kw |
|||
150QJ32-185/18 |
185 |
25kw |
|||
150QJ32-215/21 |
215 |
30kw |
This kind of well submersible pump is a clean water pump. It is strictly prohibited to dig new wells and extract sediments and turbid water. The voltage grade of the well pump is 380/50HZ. The submersible motor with other voltage grades needs to be customized. Underground cables must be waterproof cables and must be equipped with starting equipment, such as distribution box, etc. The starting equipment should have common comprehensive motor protection functions, such as short circuit overload protection, phase loss protection, undervoltage protection, grounding protection and idling protection, etc., to prevent timely tripping when abnormal conditions occur. The pump must be reliably grounded during installation and use, and it is strictly prohibited to push and pull the switch when the hands and feet are wet. The power supply must be cut off before installation and maintenance of the pump. The place where the pump is used must be set up with obvious "anti-electric shock" marks. Before going down the well or installation, the motor must be filled with distilled water or non-corrosive clean cold water in the internal chamber, and the drain bolt must be fastened. When testing the pump on the ground, water must be injected into the pump chamber to lubricate the rubber bearings. The instantaneous start time shall not exceed one second to check whether the direction is correct, and the direction is the same as the direction indicator. When the pump is erected, pay attention to safety to prevent injury from tilting. Strictly in accordance with the provisions of the pump lift and flow range of use, to avoid the pump in the low flow when the large flow or in the high lift appears in the large pull, resulting in extreme wear of thrust bearings and other components, the motor overload and burn. After the pump into the well, the insulation resistance between the motor and the ground should be measured, not less than 100MΩ. After the start, regular observation of voltage and current, and check whether the motor winding insulation meets the requirements of the provisions. If the location temperature of the pump storage is below the freezing point, the water in the motor cavity should be drained, so as not to damage the motor in winter low temperature freezing.
- Mae gosodiad pwmp 1.Submersible wedi'i gwblhau, ail-wirio'r ymwrthedd inswleiddio a dargludiad tri cham o'r switsh, gwiriwch yr offeryn a chychwyn y gwall cysylltiad offer, os nad oes problem, gall gychwyn y treial, ar ôl dechrau'r offeryn nodi darlleniadau a yw mwy na'r plât enw foltedd graddedig a nodir a'r cerrynt, arsylwi ar y sŵn pwmp a ffenomen dirgryniad, mae popeth yn normal gellir ei roi ar waith.
- 2.Dylai gweithrediad cyntaf y pwmp am bedair awr, gael ei gau i lawr yn gyflym brofi ymwrthedd inswleiddio thermol y modur, ni ddylai'r gwerth fod yn llai na 0.5 megaohm.
- 3.After y diffodd pwmp, dylid dechrau ar ôl egwyl o bum munud, er mwyn atal y golofn ddŵr yn y bibell wedi nid yn gyfan gwbl adlif a achosir gan modur gormodol presennol a burnout.
- 4.Ar ôl y pwmp i mewn i weithrediad arferol, er mwyn ymestyn ei fywyd gwasanaeth, i wirio y foltedd cyflenwad, cerrynt gweithio ac ymwrthedd inswleiddio yn normal, os canfyddir y sefyllfa ganlynol, dylid cau ar unwaith datrys problemau.
1 yn y cyflwr graddedig, mae'r presennol yn fwy nag 20%.
2 lefel dŵr deinamig i'r adran fewnfa dŵr, gan achosi dŵr ysbeidiol.
3 pwmp tanddwr dirgryniad difrifol neu sŵn.
Mae foltedd cyflenwad 4 yn is na 340 folt.
5 ffiws llosgi allan gam.
6 difrod pibell ddŵr.
7 modur i'r gwrthiant inswleiddio thermol yn llai na 0.5 megaohm.
- 5.Unit dadosod:
1 datglymwch tennyn cebl, tynnwch y rhan biblinell, tynnwch y plât gwifren.
2 sgriw i lawr y bollt dŵr, rhowch y dŵr yn y siambr modur.
3 tynnwch yr hidlydd, rhyddhewch y sgriw sefydlog ar y cyplydd i drwsio'r siafft modur.
4 sgriwiwch y bollt sy'n cysylltu'r adran fewnfa ddŵr â'r modur, a gwahanwch y pwmp o'r modur (rhowch sylw i glustog yr uned wrth wahanu, er mwyn atal y siafft pwmp rhag plygu)
5 dilyniant dadosod y pwmp yw: (gweler ffigur 1) adran fewnfa dŵr, impeller, cragen dargyfeirio, impeller ...... gwirio corff falf, wrth gael gwared ar y impeller, defnyddiwch offer arbennig i lacio llawes conigol y sefydlog impeller yn gyntaf, ac osgoi plygu a chleisio'r siafft pwmp yn y broses o ddadosod.
6 proses dadosod y modur yw: (gweler ffigur 1) gosodwch y modur ar y llwyfan, a thynnwch y cnau, y sylfaen, cnau cloi pen siafft, plât byrdwn, allwedd, sedd dwyn canllaw is a bollt pen dwbl o waelod y y modur yn ei dro, ac yna tynnwch y rotor allan (rhowch sylw i beidio â difrodi'r pecyn gwifren) ac yn olaf tynnwch yr adran gysylltu a'r sedd dwyn canllaw uchaf.
Cydosod 7 uned: cyn y cynulliad, dylid glanhau rhwd a baw y rhannau, a gorchuddio'r wyneb paru a'r caewyr â seliwr, ac yna eu cydosod yn y drefn arall o ddadosod (mae'r siafft modur yn symud i fyny ac i lawr ar ôl y cynulliad am tua un). milimedr), ar ôl cydosod, dylai'r cyplydd fod yn hyblyg, ac yna'r peiriant prawf sgrin hidlo. Rhaid tynnu pympiau tanddwr allan o'r ffynnon ar gyfer datgymalu a chynnal a chadw yn unol ag Erthygl 5 ar ôl blwyddyn o weithredu, neu lai na blwyddyn o weithredu ond dwy flynedd o amser deifio, a rhaid disodli'r rhannau treuliedig.
Mae'r cynnyrch hwn yn bwmp trydan tanddwr gyda pherfformiad rhagorol. Mae ei ddyluniad unigryw yn addas i'w ddefnyddio mewn gwahanol achlysuron. P'un a yw am atal y modur rhag rhewi yn y gaeaf neu i atal rhwd pan na chaiff ei ddefnyddio am amser hir, gall y pwmp trydan tanddwr hwn ddiwallu'ch anghenion ar gyfer cynnal a chadw offer. Mae'n syml i'w weithredu ac yn gyfleus i'w gynnal. Dilynwch y camau yn y llawlyfr ar gyfer cynnal a chadw a storio cywir, a all ymestyn bywyd gwasanaeth y cynnyrch yn effeithiol. Sicrhewch y pwmp trydan tanddwr hwn nawr a gwnewch eich gwaith yn llyfnach ac yn fwy effeithlon!
01 Cymeriant dŵr ffynnon dwfn
02 Cyflenwad dŵr uchel
03 cyflenwad dŵr mynydd
04 twr dwr
05 Dyfrhau amaethyddol
06 dyfrhau gardd
07 cymeriant dŵr afon
08 dŵr domestig