150QJ Deep Well Submersible Pump China Factory and Professional Suppliers

Leading China factory and suppliers of 150QJ deep well submersible pumps. We undertake OEM processing to design and manufacture non-standard motors and pumps per GB/T2816-2014 and GB/T2818-2014 standards. Contact us via WhatsApp 17855846335 for high-performance water solutions.
PDF DOWNLOAD
Details
Tags

The 150QJ series Deep Well Submersible Pump is a high-performance lifting solution engineered for direct connection between the submersible motor and the pump unit. Featuring a vertical, compact structure with a small footprint, this series is designed for seamless installation and simplified maintenance. It serves as an essential piece of equipment for agricultural irrigation, municipal engineering, urban water supply, and industrial mining operations, offering exceptional reliability in disaster relief drainage and diverse water conservancy projects.

Engineered for precision and durability, the 150QJ series delivers a versatile flow range from 5 to 500m³/h and a significant head lift of up to 800m, powered by motors ranging from 3 to 315KW. With a robust water-sealed wet submersible design, the motor utilizes clean water for both cooling and bearing lubrication, ensuring stable performance even in demanding environments. This combination of powerful lifting capacity and structural integrity makes it the premier choice for professional deep-well water extraction.

Detailed Parameters

Flow Range5 - 500 m³/h Maximum Head4 - 800 m
Power Range3 - 315 KW Rated Voltage380V (± 5%) / 50Hz
Water Temp Limit≤ 20 °C PH Value Range6.5 - 8.5
Impurity Content≤ 0.01% (Mass Ratio) Chloride Ion Limit≤ 400 mg/L
Max Submersion70 m Well Diameter150 mm (Standard)

Key Advantages

Robust Sealing

Equipped with double oil seals and a professional sand ring to prevent particles from entering the motor cavity.

Long Service Life

High-quality submersible winding wire ensures superior insulation and resistance to electrical wear.

Optimal Efficiency

CAD-optimized hydraulic design minimizes energy loss while maximizing water lift and flow rates.

Thermal Regulation

Integrated pressure regulating film manages temperature rise caused by motor operation efficiently.

Easy Maintenance

Compact vertical structure allows for straightforward disassembly and rapid replacement of wearing parts.

Versatile Application

Ideal for diverse scenarios from high-rise water supply to large-scale agricultural irrigation systems.

Product Gallery

Management Platforms

Precision Manufacturing

Utilizing advanced CAD design for perfect alignment and hydraulic efficiency.

Quality Control

Strict insulation resistance testing (≥ 100MΩ) before every unit shipment.

Safety Compliance

Comprehensive motor protection including short-circuit and overload prevention.

Water-Lubricated Tech

Advanced rubber bearing lubrication system reduces friction and operational noise.

Logistics Expertise

Secure packaging designed for heavy-duty industrial transport and global shipping.

After-Sales Support

Professional guidance on installation, maintenance, and wearing parts replacement.

Investment Return Comparison

Performance MetricStandard Pumps150QJ Series
Energy EfficiencyModerateHigh (CAD Optimized)
Installation TimeComplexFast (Compact Vertical)
Maintenance CycleFrequentExtended (Water-Lubricated)
LifespanStandardSuperior (High-Grade Winding)
Operational StabilityVariableConstant (Pressure Regulated)

Frequently Asked Questions

Q: What are the optimal water quality conditions for the 150QJ pump?

The pump is designed for clean water with a pH value between 6.5 and 8.5, water temperature not exceeding 20°C, and solid impurities content not greater than 0.01% by mass ratio.

Q: How should the motor be prepared before the first installation?

The motor cavity must be completely filled with clean, non-corrosive water to lubricate rubber bearings and cool the motor. Ensure the water screw is tightened and insulation resistance is measured after 12 hours.

Q: Can the 150QJ pump be used for muddy water or new wells?

No, this is a clean water pump. Pumping sediment or muddy water from new wells is strictly prohibited as it will cause premature wear and damage to the impellers and bearings.

Q: What is the minimum distance the pump should be from the well bottom?

To avoid sucking in mud or sand, the distance from the bottom of the pump to the bottom of the well should generally be no less than 3 meters.

Q: How do I protect the pump during winter storage?

To prevent the motor cavity from freezing and cracking, all water must be drained from the motor before storage in a room with temperatures below freezing.

Q: What are the common wearing parts that need replacement?

Common wearing parts include the impeller, shaft sleeve, rubber shaft sleeve, and sealing rings. We recommend a full maintenance check every year of operation.

Ready to Optimize Your Water Supply System?

Contact Us

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


Write your message here and send it to us

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.