Semi-Stainless Steel Split Series Deep Well Pump

Undertake OEM processing! According to user requirements, design and manufacture of various types of special requirements of non-standard submersible motor and pump. The product implementation standards: GB/T2816-2014 "well submersible pump", GB/T2818-2014 "well submersible asynchronous motor". WhatsApp:17855846335
PDF DOWNLOAD
Details
Tags
 
Product Overview

The use of water immersed submersible motor, rotor wear-resistant alloy sleeve and alloy thrust disc design.More durable than (oil immersed winding, rotor bearing motor), more environmentally friendly.No oil leakage after the failure of the pump, no pollution of well water, safer use.The impeller group using high strength anti-sand wear-resistant PC composite polymer materials, new three-dimensional hydraulic design, floating impeller, ceramic anti-sand structure wear resistance, full lift, large flow.Water-filled motor can dive depth of 300 meters.

 

 
Conditions of Use

This product is a three-phase AC 380V (tolerance ± 5%), 50HZ (tolerance ± 1%) power supply system, designed for strict water quality requirements. The product is suitable for water temperature not higher than 20 °C, solid impurities content (mass ratio) is not greater than 0.01%, PH value (pH) between 6.5-8.5, hydrogen sulfide content is not greater than 1.5mg/L, chloride ion content is not greater than 400mg/L environment. This product is equipped with a closed or water-filled wet structure motor, before use must be submersible motor inner cavity filled with clean water to prevent false full, and then tighten the water and air bolts, otherwise not to use. The submersible pump must be completely immersed in water to work, penetration depth shall not exceed 70 meters, the distance from the bottom of the pump to the bottom of the well shall not be less than 3 meters. In addition, the well water flow should meet the continuous operation requirements of the submersible pump, the water output of the submersible pump should be controlled at 0.7-1.2 times the rated flow. When used, the well must be vertical, and the submersible pump can not be used horizontally or dumped, only vertical installation. To ensure safety, the submersible pump must match the cable according to the requirements and be equipped with external overload protection device, and it is strictly prohibited to conduct no-load test on the pump without water. This product is an ideal choice for providing high quality water source, and can be widely used in various industrial and civil water processing fields.

 

 
Model Meaning

 
Partial Model Reference

105QJ series water-filled stainless steel deep well pump

Model

Flow

m³/h

Head

(m)

Motor

Power

(KW)

Unit

diameter

(mm)

diameter (mm)

105QJ2-230/36

2

230

4kw

103

105

105QJ2-300/50

300

5.5kw

105QJ2-390/65

390

7.5kw

105QJ4-50/10

4

50

1.1kw

103

105

105QJ4-60/12

60

1.5kw

105QJ4-80/16

80

2.2kw

105QJ4-100/20

100

3kw

105QJ4-140/28

140

4kw

105QJ4-200/40

200

5.5kw

105QJ4-275/55

275

7.5kw

105QJ6-35/10

6

35

1.1kw

103

105

105QJ6-40/12

40

1.5kw

105QJ6-60/16

60

2.2kw

105QJ6-75/20

75

3kw

105QJ6-105/28

105

4kw

105QJ6-140/40

140

5.5kw

105QJ6-192/55

192

7.5kw

105QJ8-25/5

8

25

1.1kw

103

105

105QJ8-40/8

40

1.5kw

105QJ8-55/11

55

2.2kw

105QJ8-75/15

75

3kw

105QJ8-95/19

95

4kw

105QJ8-125/25

125

5.5kw

105QJ8-160/32

160

7.5kw

105QJ10-20/5

10

20

1.1kw

103

105

105QJ10-30/8

30

1.5kw

105QJ10-40/11

40

2.2kw

105QJ10-55/15

55

3kw

105QJ10-75/19

75

4kw

105QJ10-90/25

90

5.5kw

105QJ10-120/32

120

7.5kw

105QJ16-22/9

16

22

2.2kw

103

105

105QJ16-28/12

28

3kw

105QJ16-35/15

35

4kw

105QJ16-50/20

50

5.5kw

105QJ16-68/27

68

7.5kw

 

130QJ series water-filled stainless steel deep well pump

Model

Flow

m³/h

Head

(m)

Motor

Power

(KW)

Unit

diameter

(mm)

diameter (mm)

130QJ10-60/7

10

60

1.5kw

130

135

130QJ10-80/12

80

2.2kw

130QJ10-100/15

100

3kw

130QJ10-130/20

130

4kw

130QJ10-160/25

160

5.5kw

130QJ10-220/32

220

7.5kw

130QJ10-250/38

250

9.2kw

130QJ10-300/42

300

11kw

130QJ10-350/50

350

13kw

130QJ10-400/57

400

15kw

130QJ10-450/64

450

18.5kw

130QJ10-500/70

500

22kw

130QJ15-40/5

15

40

1.5kw

130

135

130QJ15-50/7

50

2.2kw

130QJ15-60/10

60

3kw

130QJ15-80/12

80

4kw

130QJ15-105/15

105

5.5kw

130QJ15-150/22

150

7.5kw

130QJ15-170/25

170

9.2kw

130QJ15-200/28

200

11kw

130QJ15-240/34

240

13kw

130QJ15-280/40

280

15kw

130QJ15-300/42

300

18.5kw

130QJ15-336/48

336

18.5kw

130QJ15-350/50

350

22kw

130QJ15-400/56

400

22kw

 

130QJ series water-filled stainless steel deep well pump

 

Model

Flow

m³/h

Head

(m)

Motor

Power

(KW)

Unit

diameter

(mm)

diameter (mm)

130QJ20-22/3

20

30

2.2kw

130

135

130QJ20-30/5

42

3kw

130QJ20-42/6

54

4kw

130QJ20-52/8

65

5.5kw

130QJ20-72/11

85

7.5kw

130QJ20-90/14

110

9.2kw

130QJ20-105/16

128

11kw

130QJ20-130/19

145

13kw

130QJ20-150/22

164

15kw

130QJ20-182/27

182

18.5kw

130QJ20-208/31

208

22kw

130QJ20-240/35

240

25kw

130QJ20-286/42

286

30kw

130QJ25-35/6

25

35

3kw

130

135

130QJ25-40/7

40

4kw

130QJ25-52/9

52

5.5kw

130QJ25-70/12

70

7.5kw

130QJ25-85/15

85

9.2kw

130QJ25-105/18

105

11kw

130QJ25-120/21

120

13kw

130QJ25-140/24

140

15kw

 

150QJ series water-filled stainless steel deep well pump

Model

Flow

m³/h

Head

(m)

Motor

Power

(KW)

Unit

diameter

(mm)

diameter (mm)

150QJ12-40/3

12

40

2.2kw

143

150

150QJ12-55/5

55

3kw

150QJ12-80/7

80

4kw

150QJ12-107/9

107

5.5kw

150QJ12-142/11

142

7.5kw

150QJ12-175/14

175

9.2kw

150QJ12-200/16

200

11kw

150QJ12-242/19

242

13kw

150QJ12-268/21

268

15kw

150QJ12-293/23

293

18.5kw

150QJ20-28/3

20

28

3kw

143

150

150QJ20-48/5

48

4kw

150QJ20-70/7

70

5.5kw

150QJ20-90/9

90

7.5kw

150QJ20-107/11

107

9.2kw

150QJ20-135/14

135

11kw

150QJ20-155/16

155

13kw

150QJ20-175/18

175

15kw

150QJ20-195/20

195

18.5kw

150QJ20-220/22

220

18.5kw

150QJ20-235/25

235

22kw

150QJ20-255/28

255

25kw

 

150QJ series water-filled stainless steel deep well pump

Model

Flow

m³/h

Head

(m)

Motor

Power

(KW)

Unit

diameter

(mm)

diameter (mm)

150QJ45-18/2

45

18

4KW

143

150

150QJ45-28/3

28

5.5KW

150QJ45-46/5

46

7.5KW

150QJ45-57/6

57

9.2KW

150QJ45-65/7

65

11KW

150QJ45-75/8

75

13KW

150QJ45-90/10

90

15KW

150QJ45-108/12

108

18.5KW

150QJ45-125/14

125

22KW

150QJ45-145/16

145

25KW

150QJ45-168/18

168

30KW

150QJ32-20/2

32

20

3kw

143

150

150QJ32-30/3

30

4kw

150QJ32-43/4

43

5.5kw

150QJ32-60/5

60

7.5kw

150QJ32-65/6

65

7.5kw

150QJ32-75/7

75

9.2kw

150QJ32-85/8

85

11kw

150QJ32-100/9

100

13kw

150QJ32-110/10

110

15kw

150QJ32-118/11

118

18.5kw

150QJ32-140/13

140

18.5kw

150QJ32-155/15

155

22kw

150QJ32-185/18

185

25kw

150QJ32-215/21

215

30kw

 

 

 
Safety Precautions

 This kind of well submersible pump is a clean water pump. It is strictly prohibited to dig new wells and extract sediments and turbid water. The voltage grade of the well pump is 380/50HZ. The submersible motor with other voltage grades needs to be customized. Underground cables must be waterproof cables and must be equipped with starting equipment, such as distribution box, etc. The starting equipment should have common comprehensive motor protection functions, such as short circuit overload protection, phase loss protection, undervoltage protection, grounding protection and idling protection, etc., to prevent timely tripping when abnormal conditions occur. The pump must be reliably grounded during installation and use, and it is strictly prohibited to push and pull the switch when the hands and feet are wet. The power supply must be cut off before installation and maintenance of the pump. The place where the pump is used must be set up with obvious "anti-electric shock" marks. Before going down the well or installation, the motor must be filled with distilled water or non-corrosive clean cold water in the internal chamber, and the drain bolt must be fastened. When testing the pump on the ground, water must be injected into the pump chamber to lubricate the rubber bearings. The instantaneous start time shall not exceed one second to check whether the direction is correct, and the direction is the same as the direction indicator. When the pump is erected, pay attention to safety to prevent injury from tilting. Strictly in accordance with the provisions of the pump lift and flow range of use, to avoid the pump in the low flow when the large flow or in the high lift appears in the large pull, resulting in extreme wear of thrust bearings and other components, the motor overload and burn. After the pump into the well, the insulation resistance between the motor and the ground should be measured, not less than 100MΩ. After the start, regular observation of voltage and current, and check whether the motor winding insulation meets the requirements of the provisions. If the location temperature of the pump storage is below the freezing point, the water in the motor cavity should be drained, so as not to damage the motor in winter low temperature freezing.

 

 
Maintenance and Maintenance
  1. 1.Submersible pump installation is complete, re-check the insulation resistance and three-phase conduction from the switch, check the instrument and start the equipment connection error, if there is no problem, can start the trial, after the start of the instrument indicating readings whether more than the nameplate stipulated rated voltage and current, observe the pump noise and vibration phenomenon, everything is normal can be put into operation.
  2. 2.The first operation of the pump for four hours, should be shut down quickly test the thermal insulation resistance of the motor, the value should not be less than 0.5 megaohm.
  3. 3.After the pump shutdown, should be started after an interval of five minutes, to prevent the water column in the pipe has not completely reflux caused by excessive motor current and burnout.
  4. 4.After the pump into normal operation, in order to prolong its service life, to check the supply voltage, working current and insulation resistance is normal, if found the following situation, should immediately shut down troubleshooting.
  5.  

 1 in the rated condition, the current is more than 20%.

 2 dynamic water level to the water inlet section, causing intermittent water.

 3 submersible pump severe vibration or noise.

 4 supply voltage is lower than 340 volts.

 5 fuse burned out a phase.

 6 water pipe damage.

 7 motor to the thermal insulation resistance is less than 0.5 megaohm.

 

  1. 5.Unit disassembly:

 1 untie cable tether, remove the pipeline part, remove the wire plate.

 2 screw down the water bolt, put the water in the motor chamber.

 3 remove the filter, loose the fixed screw on the coupling to fix the motor shaft.

 4 screw down the bolt connecting the water inlet section with the motor, and separate the pump from the motor (pay attention to the unit cushion when separating, to prevent the bending of the pump shaft)

 5 the disassembly sequence of the pump is: (see figure 1) water inlet section, impeller, diversion shell, impeller...... check valve body, when removing the impeller, use special tools to loosen the conical sleeve of the fixed impeller first, and avoid bending and bruising the pump shaft in the process of disassembly.

 6 the disassembly process of the motor is: (see figure 1) place the motor on the platform, and remove the nuts, base, shaft head locking nut, thrust plate, key, lower guide bearing seat and double head bolt from the bottom of the motor in turn, and then take out the rotor (pay attention not to damage the wire package) and finally remove the connecting section and upper guide bearing seat.

 7 unit assembly: before assembly, the rust and dirt of the parts should be cleaned, and the mating surface and fasteners coated with sealant, and then assembled in the opposite order of disassembly (the motor shaft moves up and down after assembly for about one millimeter), after assembly, the coupling should be flexible, and then the filter screen test machine. Submersible pumps shall be taken out of the well for dismantling and maintenance according to Article 5 after a year of operation, or less than a year of operation but two years of diving time, and the worn parts shall be replaced.

 

 
Storage and Custody

This product is a submersible electric pump with excellent performance. Its unique design is suitable for use in various occasions. Whether it is to prevent the motor from freezing in winter or to prevent rust when it is not used for a long time, this submersible electric pump can meet your needs for equipment maintenance. It is simple to operate and convenient to maintain. Just follow the steps in the manual for correct maintenance and storage, which can effectively prolong the service life of the product. Get this submersible electric pump now and make your work smoother and more efficient!

 

 
Application Scenarios

01 Deep well water intake

02 High-rise water supply

03 mountain water supply 

04 tower water

05 Agricultural irrigation

06 garden irrigation

07 river water intake

08 domestic water

 

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


Write your message here and send it to us

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


en_USEnglish