175QJR Hot Water Deep Well Submersible Pump China Factory Suppliers

Leading China factory and suppliers of 175QJR deep well submersible pumps for hot water mining. We provide OEM processing and custom non-standard motor and pump designs following GB/T2816-2014 and GB/T2818-2014 standards. Contact WhatsApp 17855846335 for professional solutions.
PDF DOWNLOAD
Details
Tags

The 175QJR Deep Well Submersible Pump is a high-performance engineering solution specifically engineered for underground hot water mining operations. Built to withstand extreme conditions, this robust pump is optimized for water temperatures up to 100°C, providing exceptional resistance to high heat, chemical corrosion, and long-term aging. Its specialized construction ensures that mining operations can maintain continuous water extraction even in the most aggressive subterranean environments.

Integrating advanced water-cooled wet structure motors and precision CAD-designed hydraulics, the 175QJR series delivers unmatched stability and efficiency. Whether utilized for deep well water intake, agricultural irrigation, or industrial water supply, this pump guarantees reliable protection for your equipment and minimizes downtime. By combining high-grade insulation materials with a durable anti-sand structure, it provides a sustainable and efficient drainage solution for professional mining and water management projects.

Detailed Parameters

Power SupplyThree-phase AC 380V (±1%), 50Hz (±1%) Max Water TempUp to 100°C (Mining Grade)
Max Penetration DepthUp to 70 Meters PH Value Range6.5 - 8.5
Max Chloride Ion≤ 400mg/L H2S Content≤ 1.5mg/L
Solid ImpuritiesMass ratio ≤ 0.01% Installation ModeStrictly Vertical Only
Motor CoolingWater-filled / Water-cooled Wet Structure Min Bottom Clearance3 Meters from well bottom

Key Advantages

Corrosion Resistance

Specially treated materials prevent degradation from chemical substances and hot water minerals, extending service life.

Thermal Stability

Designed for extreme heat up to 100°C, ensuring the motor and pump body maintain integrity under thermal stress.

Anti-Sand Design

Equipped with dual oil seals and a sand ring to block debris from entering the motor cavity, reducing wear.

CAD Optimized

Precision computer-aided design ensures optimal flow dynamics and high energy efficiency across all models.

High Insulation

Uses premium winding wire for the stator to prevent electrical leakage and ensure safe operation in wet environments.

Pressure Regulation

Integrated pressure regulating film compensates for water expansion caused by temperature rises during operation.

Product Gallery

Management Platforms

Precision Installation

Strict vertical alignment and 3-meter bottom clearance to ensure stable flow and prevent vibration.

Load Protection

Mandatory external overload protection and short-circuit safeguards for motor longevity.

Water Quality Control

Strict monitoring of PH levels (6.5-8.5) and impurity ratios to prevent impeller erosion.

Insulation Testing

Routine measurement of motor-to-ground insulation (min 100MΩ) to ensure operator safety.

Thermal Monitoring

Regular checks on thermal insulation resistance after initial 4-hour operation cycles.

Maintenance Cycle

Annual disassembly and wearing parts replacement to maintain peak volumetric efficiency.

Investment Return Comparison

Performance MetricStandard Submersible Pump175QJR Specialized Pump
Max TemperatureUp to 100°C
Corrosion LifeShort (in mining water)Extended (High Resistance)
Motor ProtectionAir/Basic Water CooledWater-filled Wet Structure
Sand ToleranceLow (Prone to jamming)High (Integrated Sand Ring)
Maintenance CostHigh (Frequent Failure)Low (Long-term Stability)

Frequently Asked Questions

Q: Can the 175QJR pump be used for muddy water or sediment pumping?

No, this pump is designed for clean water. Pumping sediment, mud, or highly turbid water from new wells can cause premature wear and damage to the impeller and rubber bearings.

Q: What is the importance of filling the motor cavity with water before use?

The motor uses a water-filled wet structure for cooling and bearing lubrication. Failure to fill the cavity with clean, non-corrosive water will lead to overheating and immediate motor failure.

Q: How do I ensure the pump is installed correctly in the well?

The pump must be installed strictly vertically. Ensure a minimum distance of 3 meters from the well bottom and ensure the water inlet is at least 1-1.5 meters below the dynamic water level.

Q: What should I do if the pump vibrates violently during operation?

Immediate shutdown is required. Vibration usually indicates the pump is running against the well wall, experiencing cavitation due to low water levels, or having an unbalanced electrical phase.

Q: Can this pump handle water temperatures above 100°C?

The 175QJR is specifically designed for water temperatures below 100°C. For temperatures exceeding this limit, specialized high-temperature customized materials are required.

Q: How often should the wearing parts be replaced?

We recommend dismantling the pump for maintenance after one year of operation, or if the diving time exceeds two years, to replace impellers and sealing rings.

Ready to optimize your deep well water extraction?

Contact Us

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


Write your message here and send it to us

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.