Itilizasyon dlo a plonje motè submersible, rotor mete-rezistan alyaj manch rad ak alyaj pouse disk konsepsyon.Plis dirab pase (lwil plonje likidasyon, rotor portant motè), plis zanmitay anviwònman an.Pa gen flit lwil oliv apre echèk la nan ponp lan, pa gen polisyon nan dlo byen, itilize pi an sekirite.Gwoup la roue lè l sèvi avèk gwo fòs anti-sab usure ki reziste PC materyèl polymère konpoze, nouvo twa dimansyon konsepsyon idwolik, roue k ap flote, seramik anti-sab estrikti rezistans mete, plen leve, gwo koule. motè ka plonje pwofondè de 300 mèt.
This product is a three-phase AC 380V (tolerance ± 5%), 50HZ (tolerance ± 1%) power supply system, designed for strict water quality requirements. The product is suitable for water temperature not higher than 20 °C, solid impurities content (mass ratio) is not greater than 0.01%, PH value (pH) between 6.5-8.5, hydrogen sulfide content is not greater than 1.5mg/L, chloride ion content is not greater than 400mg/L environment. This product is equipped with a closed or water-filled wet structure motor, before use must be submersible motor inner cavity filled with clean water to prevent false full, and then tighten the water and air bolts, otherwise not to use. The submersible pump must be completely immersed in water to work, penetration depth shall not exceed 70 meters, the distance from the bottom of the pump to the bottom of the well shall not be less than 3 meters. In addition, the well water flow should meet the continuous operation requirements of the submersible pump, the water output of the submersible pump should be controlled at 0.7-1.2 times the rated flow. When used, the well must be vertical, and the submersible pump can not be used horizontally or dumped, only vertical installation. To ensure safety, the submersible pump must match the cable according to the requirements and be equipped with external overload protection device, and it is strictly prohibited to conduct no-load test on the pump without water. This product is an ideal choice for providing high quality water source, and can be widely used in various industrial and civil water processing fields.
105QJ series water-filled stainless steel deep well pump |
|||||
Modèl |
Koule m³/h |
Tèt (m) |
Motè Pouvwa (KW) |
Inite dyamèt (mm) |
diameter (mm) |
105QJ2-230/36 |
2 |
230 |
4kw |
103 |
105 |
105QJ2-300/50 |
300 |
5.5kw |
|||
105QJ2-390/65 |
390 |
7.5kw |
|||
105QJ4-50/10 |
4 |
50 |
1.1kw |
103 |
105 |
105QJ4-60/12 |
60 |
1.5kw |
|||
105QJ4-80/16 |
80 |
2.2kw |
|||
105QJ4-100/20 |
100 |
3kw |
|||
105QJ4-140/28 |
140 |
4kw |
|||
105QJ4-200/40 |
200 |
5.5kw |
|||
105QJ4-275/55 |
275 |
7.5kw |
|||
105QJ6-35/10 |
6 |
35 |
1.1kw |
103 |
105 |
105QJ6-40/12 |
40 |
1.5kw |
|||
105QJ6-60/16 |
60 |
2.2kw |
|||
105QJ6-75/20 |
75 |
3kw |
|||
105QJ6-105/28 |
105 |
4kw |
|||
105QJ6-140/40 |
140 |
5.5kw |
|||
105QJ6-192/55 |
192 |
7.5kw |
|||
105QJ8-25/5 |
8 |
25 |
1.1kw |
103 |
105 |
105QJ8-40/8 |
40 |
1.5kw |
|||
105QJ8-55/11 |
55 |
2.2kw |
|||
105QJ8-75/15 |
75 |
3kw |
|||
105QJ8-95/19 |
95 |
4kw |
|||
105QJ8-125/25 |
125 |
5.5kw |
|||
105QJ8-160/32 |
160 |
7.5kw |
|||
105QJ10-20/5 |
10 |
20 |
1.1kw |
103 |
105 |
105QJ10-30/8 |
30 |
1.5kw |
|||
105QJ10-40/11 |
40 |
2.2kw |
|||
105QJ10-55/15 |
55 |
3kw |
|||
105QJ10-75/19 |
75 |
4kw |
|||
105QJ10-90/25 |
90 |
5.5kw |
|||
105QJ10-120/32 |
120 |
7.5kw |
|||
105QJ16-22/9 |
16 |
22 |
2.2kw |
103 |
105 |
105QJ16-28/12 |
28 |
3kw |
|||
105QJ16-35/15 |
35 |
4kw |
|||
105QJ16-50/20 |
50 |
5.5kw |
|||
105QJ16-68/27 |
68 |
7.5kw |
130QJ series water-filled stainless steel deep well pump |
|||||
Modèl |
Koule m³/h |
Tèt (m) |
Motè Pouvwa (KW) |
Inite dyamèt (mm) |
diameter (mm) |
130QJ10-60/7 |
10 |
60 |
1.5kw |
130 |
135 |
130QJ10-80/12 |
80 |
2.2kw |
|||
130QJ10-100/15 |
100 |
3kw |
|||
130QJ10-130/20 |
130 |
4kw |
|||
130QJ10-160/25 |
160 |
5.5kw |
|||
130QJ10-220/32 |
220 |
7.5kw |
|||
130QJ10-250/38 |
250 |
9.2kw |
|||
130QJ10-300/42 |
300 |
11kw |
|||
130QJ10-350/50 |
350 |
13kw |
|||
130QJ10-400/57 |
400 |
15kw |
|||
130QJ10-450/64 |
450 |
18.5kw |
|||
130QJ10-500/70 |
500 |
22kw |
|||
130QJ15-40/5 |
15 |
40 |
1.5kw |
130 |
135 |
130QJ15-50/7 |
50 |
2.2kw |
|||
130QJ15-60/10 |
60 |
3kw |
|||
130QJ15-80/12 |
80 |
4kw |
|||
130QJ15-105/15 |
105 |
5.5kw |
|||
130QJ15-150/22 |
150 |
7.5kw |
|||
130QJ15-170/25 |
170 |
9.2kw |
|||
130QJ15-200/28 |
200 |
11kw |
|||
130QJ15-240/34 |
240 |
13kw |
|||
130QJ15-280/40 |
280 |
15kw |
|||
130QJ15-300/42 |
300 |
18.5kw |
|||
130QJ15-336/48 |
336 |
18.5kw |
|||
130QJ15-350/50 |
350 |
22kw |
|||
130QJ15-400/56 |
400 |
22kw |
130QJ series water-filled stainless steel deep well pump |
|||||
Modèl |
Koule m³/h |
Tèt (m) |
Motè Pouvwa (KW) |
Inite dyamèt (mm) |
diameter (mm) |
130QJ20-22/3 |
20 |
30 |
2.2kw |
130 |
135 |
130QJ20-30/5 |
42 |
3kw |
|||
130QJ20-42/6 |
54 |
4kw |
|||
130QJ20-52/8 |
65 |
5.5kw |
|||
130QJ20-72/11 |
85 |
7.5kw |
|||
130QJ20-90/14 |
110 |
9.2kw |
|||
130QJ20-105/16 |
128 |
11kw |
|||
130QJ20-130/19 |
145 |
13kw |
|||
130QJ20-150/22 |
164 |
15kw |
|||
130QJ20-182/27 |
182 |
18.5kw |
|||
130QJ20-208/31 |
208 |
22kw |
|||
130QJ20-240/35 |
240 |
25kw |
|||
130QJ20-286/42 |
286 |
30kw |
|||
130QJ25-35/6 |
25 |
35 |
3kw |
130 |
135 |
130QJ25-40/7 |
40 |
4kw |
|||
130QJ25-52/9 |
52 |
5.5kw |
|||
130QJ25-70/12 |
70 |
7.5kw |
|||
130QJ25-85/15 |
85 |
9.2kw |
|||
130QJ25-105/18 |
105 |
11kw |
|||
130QJ25-120/21 |
120 |
13kw |
|||
130QJ25-140/24 |
140 |
15kw |
150QJ series water-filled stainless steel deep well pump |
|||||
Modèl |
Koule m³/h |
Tèt (m) |
Motè Pouvwa (KW) |
Inite dyamèt (mm) |
diameter (mm) |
150QJ12-40/3 |
12 |
40 |
2.2kw |
143 |
150 |
150QJ12-55/5 |
55 |
3kw |
|||
150QJ12-80/7 |
80 |
4kw |
|||
150QJ12-107/9 |
107 |
5.5kw |
|||
150QJ12-142/11 |
142 |
7.5kw |
|||
150QJ12-175/14 |
175 |
9.2kw |
|||
150QJ12-200/16 |
200 |
11kw |
|||
150QJ12-242/19 |
242 |
13kw |
|||
150QJ12-268/21 |
268 |
15kw |
|||
150QJ12-293/23 |
293 |
18.5kw |
|||
150QJ20-28/3 |
20 |
28 |
3kw |
143 |
150 |
150QJ20-48/5 |
48 |
4kw |
|||
150QJ20-70/7 |
70 |
5.5kw |
|||
150QJ20-90/9 |
90 |
7.5kw |
|||
150QJ20-107/11 |
107 |
9.2kw |
|||
150QJ20-135/14 |
135 |
11kw |
|||
150QJ20-155/16 |
155 |
13kw |
|||
150QJ20-175/18 |
175 |
15kw |
|||
150QJ20-195/20 |
195 |
18.5kw |
|||
150QJ20-220/22 |
220 |
18.5kw |
|||
150QJ20-235/25 |
235 |
22kw |
|||
150QJ20-255/28 |
255 |
25kw |
150QJ series water-filled stainless steel deep well pump |
|||||
Modèl |
Koule m³/h |
Tèt (m) |
Motè Pouvwa (KW) |
Inite dyamèt (mm) |
diameter (mm) |
150QJ45-18/2 |
45 |
18 |
4KW |
143 |
150 |
150QJ45-28/3 |
28 |
5.5KW |
|||
150QJ45-46/5 |
46 |
7.5KW |
|||
150QJ45-57/6 |
57 |
9.2KW |
|||
150QJ45-65/7 |
65 |
11KW |
|||
150QJ45-75/8 |
75 |
13KW |
|||
150QJ45-90/10 |
90 |
15KW |
|||
150QJ45-108/12 |
108 |
18.5KW |
|||
150QJ45-125/14 |
125 |
22KW |
|||
150QJ45-145/16 |
145 |
25KW |
|||
150QJ45-168/18 |
168 |
30KW |
|||
150QJ32-20/2 |
32 |
20 |
3kw |
143 |
150 |
150QJ32-30/3 |
30 |
4kw |
|||
150QJ32-43/4 |
43 |
5.5kw |
|||
150QJ32-60/5 |
60 |
7.5kw |
|||
150QJ32-65/6 |
65 |
7.5kw |
|||
150QJ32-75/7 |
75 |
9.2kw |
|||
150QJ32-85/8 |
85 |
11kw |
|||
150QJ32-100/9 |
100 |
13kw |
|||
150QJ32-110/10 |
110 |
15kw |
|||
150QJ32-118/11 |
118 |
18.5kw |
|||
150QJ32-140/13 |
140 |
18.5kw |
|||
150QJ32-155/15 |
155 |
22kw |
|||
150QJ32-185/18 |
185 |
25kw |
|||
150QJ32-215/21 |
215 |
30kw |
This kind of well submersible pump is a clean water pump. It is strictly prohibited to dig new wells and extract sediments and turbid water. The voltage grade of the well pump is 380/50HZ. The submersible motor with other voltage grades needs to be customized. Underground cables must be waterproof cables and must be equipped with starting equipment, such as distribution box, etc. The starting equipment should have common comprehensive motor protection functions, such as short circuit overload protection, phase loss protection, undervoltage protection, grounding protection and idling protection, etc., to prevent timely tripping when abnormal conditions occur. The pump must be reliably grounded during installation and use, and it is strictly prohibited to push and pull the switch when the hands and feet are wet. The power supply must be cut off before installation and maintenance of the pump. The place where the pump is used must be set up with obvious "anti-electric shock" marks. Before going down the well or installation, the motor must be filled with distilled water or non-corrosive clean cold water in the internal chamber, and the drain bolt must be fastened. When testing the pump on the ground, water must be injected into the pump chamber to lubricate the rubber bearings. The instantaneous start time shall not exceed one second to check whether the direction is correct, and the direction is the same as the direction indicator. When the pump is erected, pay attention to safety to prevent injury from tilting. Strictly in accordance with the provisions of the pump lift and flow range of use, to avoid the pump in the low flow when the large flow or in the high lift appears in the large pull, resulting in extreme wear of thrust bearings and other components, the motor overload and burn. After the pump into the well, the insulation resistance between the motor and the ground should be measured, not less than 100MΩ. After the start, regular observation of voltage and current, and check whether the motor winding insulation meets the requirements of the provisions. If the location temperature of the pump storage is below the freezing point, the water in the motor cavity should be drained, so as not to damage the motor in winter low temperature freezing.
- 1.Enstalasyon ponp submersible konplè, re-tcheke rezistans izolasyon ak kondiksyon twa-faz soti nan switch la, tcheke enstriman an epi kòmanse erè koneksyon ekipman an, si pa gen okenn pwoblèm, ka kòmanse jijman an, apre yo fin kòmanse enstriman an. endike lekti si plis pase plak la make rated vòltaj ak aktyèl, obsève bri ponp lan ak fenomèn Vibration, tout bagay se nòmal yo ka mete nan operasyon.
- 2.Premye operasyon ponp lan pou kat èdtan, yo ta dwe fèmen byen vit tès rezistans izolasyon tèmik motè a, valè a pa ta dwe mwens pase 0.5 megaohm.
- 3.Apre ponp lan fèmen, yo ta dwe kòmanse apre yon entèval senk minit, yo anpeche kolòn dlo a nan tiyo a pa te konplètman rflu ki te koze pa aktyèl motè twòp ak boule.
- 4.Apre ponp lan nan operasyon nòmal, yo nan lòd yo pwolonje lavi sèvis li yo, yo tcheke vòltaj la ekipman pou, k ap travay aktyèl ak rezistans izolasyon se nòmal, si yo jwenn sitiyasyon sa a, yo ta dwe imedyatman fèmen depanaj.
1 nan kondisyon an rated, aktyèl la se plis pase 20%.
2 nivo dlo dinamik nan seksyon inlet dlo a, sa ki lakòz dlo tanzantan.
3 ponp submersible vibrasyon grav oswa bri.
4 vòltaj ekipman pou pi ba pase 340 volts.
5 fusible boule yon faz.
6 domaj tiyo dlo.
7 motè a rezistans nan izolasyon tèmik se mwens pase 0.5 megaohm.
- 5.Inite demonte:
1 demare kab tether, retire pati tiyo a, retire plak fil la.
2 vis desann boulon dlo a, mete dlo a nan chanm motè a.
3 retire filtè a, lage vis fiks la sou kouple a pou ranje arbr motè a.
4 vis desann boulon ki konekte seksyon inlet dlo a ak motè a, epi separe ponp lan ak motè a (peye atansyon sou kousen inite a lè w ap separe, pou anpeche koube ponp lan)
5 sekans demonte ponp lan se: (gade figi 1) dlo inlet seksyon, roue, détournement shell, roue ...... tcheke kò valv, lè retire roue a, sèvi ak zouti espesyal pou dekole manch konik la nan fiks la. impeller premye, epi evite koube ak ematom arbr ponp lan nan pwosesis la nan demonte.
6 pwosesis la demonte nan motè a se: (gade figi 1) mete motè a sou platfòm la, epi retire nwa yo, baz, arbr tèt nwa bloke, plak poussée, kle, pi ba chèz kote yo pote gid ak boulon tèt doub anba a nan motè a nan vire, ak Lè sa a, pran rotor la (peye atansyon pa domaje pake a fil) epi finalman retire seksyon an konekte ak chèz anwo kote yo pote gid.
7 asanble inite: anvan asanble, yo ta dwe netwaye rouye ak pousyè tè nan pati yo, epi sifas kwazman an ak fixation kouvwi ak selan, ak Lè sa a, reyini nan lòd opoze a demonte (arbr a motè deplase monte desann apre asanble pou apeprè yon sèl. milimèt), apre asanble, kouple a ta dwe fleksib, ak Lè sa a, machin nan tès ekran filtre. Ponp submersible yo dwe pran soti nan pi a pou demantèlman ak antretyen dapre Atik 5 apre yon ane nan operasyon, oswa mwens pase yon ane nan operasyon men de ane nan tan plonje, ak pati yo chire yo dwe ranplase.
Pwodwi sa a se yon ponp elektrik submersible ak pèfòmans ekselan. Konsepsyon inik li apwopriye pou itilize nan divès okazyon. Kit se pou anpeche motè a konjele nan sezon fredi oswa pou anpeche rouye lè li pa itilize pou yon tan long, ponp elektrik submersible sa a ka satisfè bezwen ou yo pou antretyen ekipman yo. Li senp pou opere ak pratik pou kenbe. Jis swiv etap sa yo nan manyèl la pou antretyen kòrèk ak depo, ki ka efektivman pwolonje lavi sa a ki sèvis nan pwodwi a. Jwenn ponp elektrik submersible sa a kounye a epi fè travay ou pi dous ak pi efikas!
01 Konsomasyon dlo byen fon
02 Pwovizyon dlo ki wo
03 rezèv dlo mòn
04 gwo kay won dlo
05 Irigasyon agrikòl
06 irigasyon jaden
07 konsomasyon dlo rivyè
08 dlo domestik