200QJ Deep Well dompelpomp

Undernimme OEM-ferwurking! Neffens brûker easken, ûntwerp en fabrikaazje fan ferskate soarten spesjale easken fan net-standert dompelmotor en pomp. Produktimplementaasjenormen: GB/T2816-2014 "goed dompelpomp", GB / T2818-2014 "goed dompelbere asynchrone motor". WhatsApp: 17855846335
PDF DOWNLOAD
Details
Tags
 
produktoersjoech

QJ series submersible pump is a kind of water lifting machine directly connected to the submersible motor and pump to work in the water. This series of pumps is vertical, small use area, compact structure, easy installation, easy maintenance and repair. Widely used in agricultural irrigation, municipal engineering, water conservancy engineering, urban water supply and drainage and industrial and mining enterprises, drought relief and flood drainage and other fields. Flow range of 5-500m3/h, lift of 4-800m, power 3-315KW. The QJ series submersible pump has stable and reliable performance, suitable for various needs of pump applications.

 
Betingsten fan gebrûk

1, Netzteil: trije-fase AC 380V (tolerânsje + / - 5%), 50HZ (tolerânsje + / - 1%).

2, wetterkwaliteit:

(1) water temperature is not higher than 20 °C;

(2) fêste ûnreinheden ynhâld (massa ratio) is net grutter as 0,01%;

(3) PH wearde (pH) 6,5-8,5;

(4) wetterstof sulfide ynhâld is net grutter as 1.5mg / L;

(5) chloride ion ynhâld is net grutter as 400mg / L.

3, the motor is closed or water-filled wet structure, before use the submersible motor cavity must be full of clean water, to prevent false full, and then tighten the water injection, air release bolts, otherwise not allowed to use.

4, dompelpomp moat folslein ûnderdompele wurde yn it wetter, de dûkdjipte is net grutter as 70m, de boaiem fan 'e dompelpomp fan' e boaiem fan 'e put is net minder as 3m.

5, de put wetter stream moat wêze kinne om te foldwaan oan de submersible pomp wetter útfier en trochgeande operaasje, de submersible pomp wetter útfier moat wurde regele op 0,7 - 1,2 kear de rated stream.

6, de put moat rjocht wêze, de dompelpomp kin net brûkt wurde of dumpt, allinich fertikaal gebrûk.

7, de dompelpomp moat wurde matched mei de kabel neffens de easken, en de eksterne overload beskerming apparaat.

8, the pump is strictly prohibited without water no-load test machine.

 

 
Model Meaning

200QJ Deep Well Submersible Pump

 
Partial Model Reference
Model Flow (m3/h) Holle
(m)

Rotatingspeed

(feroarje/punt)

Wetterpomp(%)  Outlet
diameter
(mm)
Goed tapast
diameter (mm) 
 Rated
power(KW)
Rated
spanning (V)
Rated
aktuele (A)
Motor effisjinsje (%) power factorcosφ   Ienheid
Radiale Maksimum grutte (mm)
Opmerking
200QJ20-40 20 40 2850 66 50  200boppe 4 380 10.1 76.0 0.79 184  
200QJ20-54 54 5.5 13.6 77.0 0.8  
200QJ20-81 81 7.5 18.0 78.0 0.81  
200QJ20-93 93 9.2 21.7 78.5 0.82  
200QJ20-108 108 11 25.8 79.0 0.82  
200QJ20-121 121 13 29.8 80.0 0.83  
200QJ20-148 148 15 33.9 81.0 0.83  
200QJ20-175 175 18.5 41.6 81.5 0.83  
200QJ20-202 202 22 48.2 82.5 0.84  
200QJ20-243 243 25 54.5 83.0 0.84  
200QJ20-270 270 30 65.4 83.0 0.84  
200QJ20-360 360 37 79.7 84.0 0.84  
200QJ20-442 442 45 96.9 84.0 0.84  
200QJ25-28 25 28 2850 68 65  200boppe 4 380 10.1 76.0 0.79 184  
200QJ25-42 42 5.5 13.6 77.0 0.8  
200QJ25-56 56 7.5 18.0 78.0 0.81  
200QJ25-70 70 9.2 21.7 78.5 0.82  
200QJ25-98 98 11 25.8 79.0 0.82  
200QJ25-112 25 112 2850 68 65  200boppe 13 380 29.8 80.0 0.83 184  
200QJ25-126 126 15 33.9 81.0 0.83  
200QJ25-154 154 18.5 41.6 81.5 0.83  
200QJ25-182 182 22 48.2 82.5 0.84  
200QJ25-210 210 25 54.5 83.0 0.84  
200QJ25-252 252 30 65.4 83.0 0.84  
200QJ25-308 308 37 79.7 84.0 0.84  
200QJ25-378 378 45 96.9 84.0 0.84  
200QJ32-26 32 26 2850 70 80  200boppe 4 380 10.1 76.0 0.79 184  
200QJ32-39 39 5.5 13.6 77.0 0.8  
200QJ32-52 52 7.5 18.0 78.0 0.81  
200QJ32-65 65 9.2 21.7 78.5 0.82  
200QJ32-78 78 11 25.8 79.0 0.82  
200QJ32-91 91 13 29.8 80.0 0.83  
200QJ32-104 104 15 33.9 81.0 0.83  
200QJ32-130 130 18.5 41.6 81.5 0.83  
200QJ32-143 143 22 48.2 82.5 0.84  
200QJ32-169 169 25 54.5 83.0 0.84  
200QJ32-195 195 30 65.4 83.0 0.84  
200QJ32-247 247 37 79.7 84.0 0.84  
200QJ32-299 299 45 96.9 84.0 0.84  
200QJ40-26 40 26 2850 72 80  200boppe 5.5 380 13.6 77.0 0.8 184  
200QJ40-39 39 7.5 18.0 78.0 0.81  
200QJ40-52 52 9.2 21.7 78.5 0.82  
200QJ40-65 65 11 25.8 79.0 0.82  
200QJ40-78 78 15 33.9 81.0 0.83  
200QJ40-104 104 18.5 41.6 81.5 0.83  
200QJ40-117 117 22 48.2 82.5 0.84  
200QJ40-143 143 25 54.5 83.0 0.84  
200QJ40-169 169 30 65.4 83.0 0.84  
200QJ40-208 208 37 79.7 84.0 0.84  
200QJ40-247 247 45 96.9 84.0 0.84  
200QJ50-26 50 26 2850 74 80  200boppe 5.5 380 13.6 77.0 0.8 184  
200QJ50-39 39 9.2 21.7 78.5 0.82  
200QJ50-52 52 11 25.8 79.0 0.82  
200QJ50-65 65 15 33.9 81.0 0.83  
200QJ50-78 78 18.5 41.6 81.5 0.83  
200QJ50-91 91 22 48.2 82.5 0.84  
200QJ50-104 104 25 54.5 83.0 0.84  
200QJ50-130 130 30 65.4 83.0 0.84  
200QJ50-156 156 37 79.7 84.0 0.84  
200QJ50-208 208 45 96.9 84.0 0.84  
200QJ63-24 63 24 2850 74 80  200boppe 7.5 380 18.0 78.0 0.81 184  
200QJ63-36 36 11 25.8 79.0 0.82  
200QJ63-60 60 18.5 41.6 81.5 0.83  
200QJ63-72 72 22 48.2 82.5 0.84  
200QJ63-84 84 25 54.5 83.0 0.84  
200QJ63-96 96 30 65.4 83.0 0.84  
200QJ63-120 120 37 79.7 84.0 0.84  
200QJ63-144 144 45 96.9 84.0 0.84  
200QJ80-22 80 22 2850 75 100  200boppe 7.5 380 18.0 78.0 0.81 184  
200QJ80-33 33 11 25.8 79.0 0.82  
200QJ80-44 44 15 33.9 81.0 0.83  
200QJ80-55 55 18.5 41.6 81.5 0.83  
200QJ80-66 66 22 48.2 82.5 0.84  
200QJ80-88 88 30 65.4 83.0 0.84  
200QJ80-99 99 37 79.7 84.0 0.84  
200QJ80-121 121 45 96.9 84.0 0.84  
200QJ100-18 100 18 2850 75 100  200boppe 9.2 380 21.7 78.5 0.82 184  
200QJ100-27 27 13 29.8 80.0 0.83  
200QJ100-36 36 18.5 41.6 81.5 0.83  
200QJ100-45 45 22 48.2 82.5 0.84  
200QJ100-54 54 25 54.5 83.0 0.84  
200QJ100-63 63 30 65.4 83.0 0.84  
200QJ100-72 100 72 2850 75 100  200boppe 37 380 79.7 84.0 0.84 184  
200QJ100-90 90 45 96.9 84.0 0.84  

 

 

 
Feiligens foarsoarchsmaatregels

1, well submersible pump for clean water pump, prohibit the new well, pumping sediment and muddy water,

2, well water pump voltage grade of 380/50HZ, the use of other voltage grades of submersible motors need to be customized. The underground cable must use waterproof cable, must be equipped with starting equipment, such as distribution box, start not ready should have commonly used motor comprehensive protection function, such as short circuit overload protection, phase protection, undervoltage protection, grounding protection, idling protection, in case of abnormal conditions, the protection device should be timely action trip.

3, the installation and use of the pump must be reliably grounded, prohibit the push and pull switch when the hands and feet are wet, the installation and maintenance of the pump must be cut off the power supply, the use of the pump place to set up "to prevent electric shock" obvious signs:

4, down the well or before installation, the motor cavity must be filled with distilled water or non-corrosive clean cold boiling water, tighten the / water bolt, the pump on the ground test run, must be to the pump chamber water lubrication rubber bearings, instant start not more than a second, see whether the steering is the same as the steering instructions. When the pump is upright, pay attention to safety, prevent overturning injury.

5, strikt neffens de bepalingen fan 'e pomp lift, flow berik fan gebrûk, om foar te kommen lege stream of hege lift pompen krêft, de thrust bearing en oare dielen fan' e wear, de motor overload ferbaarnd 6, neidat de pomp del de put, de mjitting fan de motor oan 'e grûn isolaasje wjerstân moat net minder as 100M, nei it begjin te observearjen de spanning en stroom, kontrolearje de motor winding isolaasje, oft yn oerienstimming mei de easken; pomp opslach lokaasje temperatuer as minder as friespunt, moat wêze droech de motor holte wetter, foarkomme de motor holte wetter iis skea feroarsake troch lege temperatuer.

 

 
Ynlieding ta Struktuer

Structure brief: pump part is mainly composed of pump shaft, impeller, diversion shell, rubber bearing, check valve body (optional parts) and other components.The motor part is mainly composed of base, pressure regulating film, thrust bearing, thrust plate, lower guide bearing seat, stator, rotor, upper guide bearing seat, sand ring, water inlet section, cable and other components.


De wichtichste skaaimerken fan it produkt binne:

 1, De motor is in wetterfol wiete submersible trije-fase asynchrone motor, de motorholte is fol mei skjin wetter, brûkt om de motor te koelen en it lager te smeren, de drukregulearjende film oan 'e ûnderkant fan' e motor wurdt brûkt om oan te passen de útwreiding en krimp druk ferskil fan it wetter binnen it lichem feroarsake troch de feroaring fan de temperatuer stiging fan de motor.

 2, Om foar te kommen dat it sân yn it putwetter yn 'e motor komt, is it boppeste ein fan' e motoras foarsjoen fan twa oaljedichtingen, en in sânring is ynstalleare om in sânprevinsjestruktuer te foarmjen.

 3, Om foar te kommen dat de pomp skacht rint omheech by it starten, de pomp skacht en de motor skacht wurde ferbûn troch in coupling, en in boppeste triuw bearing wurdt ynstallearre op it legere diel fan 'e motor.

 4, De smering fan 'e motor en it pomplager is wettersmering.

 5, De motorstatorwinding is makke fan heechweardige submersible motorwindende draad, mei hege isolaasjeprestaasjes.

 6, De pomp is ûntwurpen troch kompjûter CAD, mei ienfâldige struktuer en goede technyske prestaasjes.

200QJ Deep Well Submersible Pump
 
Ynstallearje

(1) Tarieding foar ynstallaasje:
1. Kontrolearje oft de dompelpomp foldocht oan de gebrûksbetingsten en omfang spesifisearre yn 'e hantlieding.
2. Mei in swiere objekt mei in diameter lyk oan de maksimale bûtendiameter fan 'e dompelpomp, mjitte oft de binnendiameter fan' e putboring de dompelpomp passe kin, en mjit oft de putdjipte foldocht oan de ynstallaasjeeasken.
3. Kontrolearje oft de putboring skjin is en oft it putwetter troebel is. Nea brûke in dompelpomp elektryske pomp te waskjen de welor pomp modder en sân wetter te kommen foar betiid skea oan de dompelpomp elektryske pomp.
4. Kontrolearje oft de posysje fan de welhead ynstallaasje clamp is geskikt en oft it kin wjerstean de kwaliteit fan de hiele ienheid
5. Kontrolearje oft de submersible pomp ûnderdielen binne kompleet en ynstallearre goed neffens de gearstalling diagram yn de hânlieding Ferwiderje it filter skerm en draaie de koppeling om te sjen oft it draait fleksibel
6. Skroef de wetterskroef los en folje de motorholte mei skjin, net-korrosyf wetter (notysje. Wês wis dat it opfolje), dan draait de wetterskroef oan. Nei 12 oeren fan wetterynjeksje moat de isolaasjeferset fan 'e motor net minder wêze dan 150M Q as mjitten mei in 500V skoddetafel.
7. Cable joint, cut off a 120mm rubber sleeve from one end of the outgoing cable and the matching cable with an electrician's knifethen stagger the length of the three core wires in a stepped shape, peel off a 20mm copper core, scrape of the oxide layer on theoutside of the copper wire with a knife or sand cloth, and insert the two connected wire ends in palirs.After tying the layer tightly with fine copper wire, solder it thoroughly and firmly, and sand of any. burrs on the surface. Then, forthe three joints, use polyvester insulation tape to wrap them in a semi stacked manner for three lavers. Wrap the two ends of thewrapping layer tightywith nyion thread,and then use a semi stacked method to wrap the tape for three layers. Wrap the outellayer with high-pressure insulation tape for three layers. Finally, fold the threestrands together and repeatedly wrap them for fivelayers with high-pressure tape. Each layer must be tightly tied, and the interlayer joints must be tight and fimm to prevent water frompenetrating and damaging the insulation, After wrapping, soak in water at room temperature of 20 ’c for 12 hours, and measurethe insulation resistance with a shaking table, which should not be less than 100M Ω

 

It taheakke prosesdiagram foar kabelbedrading is as folget:
200QJ Deep Well Submersible Pump

 

8. Brûk in multimeter om te kontrolearjen oft de trije-fase triedden binne ferbûn en oft de DC ferset is likernôch lykwichtich.
9. Kontrolearje oft it circuit en transformator kapasiteit binne oerladen, en dan ferbinen de oerlêst beskerming switch of begjinnende apparatuer. Sjoch Tabel 2 foar spesifike modellen, en dan Giet in amer mei wetter yn 'e wetterpomp út' e wetterpompútlaat om de rubberlagers yn 'e pomp te smeerjen, en set dan de ûnderdompelbere elektryske pomp rjochtop en steady.Start (net mear as ien sekonde) en kontrolearje oft de stjoerrjochting oerienkomt mei it stjoerteken. As net, ruilje alle twa Anschlüsse fan 'e trije-faze kabel. Ynstallearje dan it filter en meitsje jo klear om de put del te gean. As brûkt by spesjale gelegenheden (lykas sleatten, sleatten, rivieren, fivers, fivers, ensfh.), De elektryske pomp moat betrouber wurde grûn.

 

(2) Ynstallaasje apparatuer en ark:
1. Ien pear liftkeatlingen foar mear as twa ton.
2. In tripod mei in fertikale hichte fan net minder as fjouwer meter.
3. Twa hingjende touwen (wire touwen) dy't in gewicht fan mear as ien ton drage kinne (kinne it gewicht fan in folsleine set wetterpompen drage).
4. Ynstallearje twa pearen fan clamps (spalken).
5. Wrenches, hammers, schroevendraaiers, elektryske ark en ynstruminten, ensfh.

 

(3) Elektryske pomp ynstallaasje:
1. It ynstallaasjediagram fan 'e ûnderdompele elektryske pomp wurdt werjûn yn figuer 2. De spesifike ynstallaasjedimensjes wurde werjûn yn Tabel 3 "List fan ynstallaasje-ôfmjittings fan 'e ûnderdompele elektryske pomp".

 

2. Submersible elektryske pompen mei in kop minder as 30 meter kinne direkt yn 'e boarne ophelle wurde mei slangen en draadseilen of oare himp-touwen dy't it folsleine gewicht fan' e hiele masine, wetterpipes, en wetter yn 'e pipes drage kinne.

 

3. Pompen mei in kop fan mear as 30 meter brûke stielen pipen, en de ynstallaasje folchoarder is as folget:
①Gebrûk in klem om it boppeste ein fan it wetterpompdiel te klemmen (de motor en de wetterpomp binne op dit stuit ferbûn), til it mei in hingjende keatling op en bine it stadichoan yn 'e put oant Set de klem op' e putkop en fuortsmite hingjende ketting.
② Brûk in oar pear klemmen om in piip te klemmen, til it mei in hingjende ketting 15 sm fuort fan 'e flange, en ferleegje it stadich. Tusken pipe flange en pomp flangePut de rubberen pad yn plak en strak de piip en pomp gelyk mei bouten, moeren en spring washers.
③ Til de dompelpomp in bytsje op, ferwiderje de klem op 'e boppeste ein fan' e wetterpomp, bine de kabel stevich oan 'e wetterpipe mei in plestik tape, en bûgje it stadichoan oant De klem wurdt pleatst by de putkop.
④Brûk deselde metoade om alle wetterpipes yn 'e put te binen.
⑤ Neidat de lead-out kabel is ferbûn mei de kontrôle switch, it is ferbûn oan de trije-fase Netzteil.


(4) Dingen om op te merken by ynstallaasje:
1. As in jamming ferskynsel wurdt fûn tidens it pompen proses, draaie of lûke de wetter piip te oerwinnen it jamming punt. As ferskate maatregels noch net wurkje, twinge asjebleaft de pomp net omleech om skea oan 'e dompelpomp en de put te foarkommen.
2. By ynstallaasje moat in rubberen pad op 'e flange fan elke piip pleatst wurde en gelijkmatig oanskerpe.
3. As de wetterpomp yn 'e boarne ferlege wurdt, moat it yn' e midden fan 'e putpipe pleatst wurde om te foarkommen dat de pomp lang tsjin' e wellmuorre rint, wêrtroch't de pomp trillet en de motor sweep en brânt .
4. Bepale de djipte fan 'e wetterpomp nei de boaiem fan' e boarne neffens de streamende sân- en siltbetingsten fan 'e boarne. Begrave de pomp net yn 'e modder. De ôfstân fan 'e wetterpomp nei de boaiem fan' e put is oer it generaal net minder as 3 meter (sjoch figuer 2).
5. De wetteryngongsdjipte fan 'e wetterpomp moat net minder wêze as 1-1,5 meter fan it dynamyske wetterpeil nei it wetteryntreeknooppunt (sjoch figuer 2). Oars kinne de wetterpomplagers maklik skea wurde.
6. De lift fan 'e wetterpomp kin net te leech wêze. Oars, in poarte fentyl moat wurde ynstallearre op de wellhead wetter pipeline te kontrolearjen de pomp trochstreaming op de rated flow punt om foar te kommen dat de motor wurdt oerladen en útbaarnd fanwege grutte stream tariven.
7. As de wetterpomp rint, moat de wetterútfier kontinuële en sels wêze, de aktuele moat stabyl wêze (ûnder beoardielde wurkomstannichheden, oer it generaal net mear as 10% fan 'e nominearre aktuele), en der moat gjin trilling of lûd wêze. As der in abnormaliteit is, moat de masine wurde stoppe om de oarsaak te finen en it te eliminearjen.
8. By it ynstallearjen, betelje omtinken oan de ynstelling fan 'e motor grûndraad (sjoch figuer 2). As it wetter piip is in stielen piip, liedt it út de puthead clamp; as it wetter piip is in plestik piip, liedt it út 'e grûn mark fan' e elektryske pomp.

 

 
Ûnderhâld en ûnderhâld
  1. (1)After the submersible pump is installed, check the insulation resistance and three-phase conduction from the switch again, check whether the instrument and the connection of the start equipment are wrong, if there is no problem, the trial machine can be started, and observe whether the indicator readings of the instrument exceed the rated voltage and current specified on the nameplate after the start, and observe whether the pump has noise and vibration phenomenon. If everything is normal, it can be put into operation.
  2. (2) After the first operation of the pump for four hours, the motor should be shut down to test the thermal insulation resistance quickly, and its value should not be less than 0.5 megaohm.
  3. (3) After the pump is shut down, it should be started after five minutes to prevent the water column in the pipe from being completely reflowed and causing the motor to burn out due to excessive current.
  4. (4)After the pump is put into normal operation, in order to prolong its service life, it is necessary to check regularly whether the supply voltage, running current and insulation resistance are normal.If the following conditions are found, the pump should be shut down immediately to eliminate the fault:
  5. 1 under the rated working conditions, the current exceeds 20%;
  6. 2 the dynamic water level drops to the water inlet part, resulting in intermittent drainage;
  7. 3 the submersible pump vibrates seriously or emits huge noise;
  8. 4 the supply voltage is lower than 340 volts;
  9. 5 a fuse is blown out;
  10. 6 the water pipe is damaged;
  11. 7 the thermal insulation resistance between the motor and the ground is less than 0.5 megaohm. The discovery of these problems need to be handled in time to ensure the normal operation of the pump, improve its reliability, so as to ensure the stable operation of the equipment for a long time.

 

(5)unit disassembly:

 1 untie the cable tie, remove the pipeline part, remove the wire plate.

 2 skroef de wetterbout del, set it wetter yn 'e motorkeamer.

 3 remove the filter, loose the fixing screw on the coupling to fix the motor shaft.

 4 screw down the bolt connecting the water inlet section with the motor, separate the pump and the motor (pay attention to the unit cushion when separating, prevent the bending of the pump shaft)

 5 pump disassembly sequence is: (see figure 1) water inlet section, impeller, diversion shell, impeller...... check valve body, when removing the impeller, use special tools to loosen the conical sleeve of the fixed impeller first, avoid bending the pump shaft and each part in the disassembly process.

 6 motor disassembly process is: (see figure 1) place the motor on the platform, and remove the nut, base, shaft head lock nut, thrust plate, key, lower guide bearing seat, double head bolt from the bottom of the motor in turn. Then take out the rotor (pay attention not to damage the wire package) and finally remove the connecting section and the upper guide bearing seat.

 7 unit assembly: Before assembly, the rust and dirt of the parts should be cleaned, and the mating surfaces and fasteners should be coated with sealant. Then they should be assembled in the reverse order of disassembly (the up and down momentum of the motor shaft is about 1 mm after assembly). After assembly, the coupling should be flexible, and then the filter screen test machine.

  1. The submersible pump should be dismantled and repaired according to Article 5 for each operation year, or less than one year, but the submersible time has reached two years, and the worn parts should be replaced.

 

 
Opslach en bewar

 1, set it wetter yn 'e motorholte (benammen yn' e winter om foar te kommen dat de motor befriest), en bine de kabel goed.

 2, store in an indoor room without corrosive substances and gases, with a temperature below 40 °C.

 3, lange-termyn gebrûk moatte betelje omtinken foar de roest previnsje fan dompelpompen.

 

 
Wearing Parts
  • Impeller
  • Shaft mouwe
  • Rubber shaft sleeve
  • Segelring

 
Applikaasje senario

01 Djippe boarne wetter yntak

02 Hege wetterfoarsjenning

03 berch wetterfoarsjenning 

04 toer wetter

05 Agraryske yrrigaasje

06 tún yrrigaasje

07 rivier wetter yntak

08 húshâldlik wetter

 

As jo ​​ynteressearre binne yn ús produkten, kinne jo kieze in ferlitte jo ynformaasje hjir, en wy sille yn kontakt mei jo koart.


Skriuw jo berjocht hjir en stjoer it nei ús

As jo ​​ynteressearre binne yn ús produkten, kinne jo kieze in ferlitte jo ynformaasje hjir, en wy sille yn kontakt mei jo koart.


fyFrisian