SP Series All Stainless Steel Water Filled Deep Well Pump

Undernimme OEM-ferwurking! Neffens brûker easken, ûntwerp en fabrikaazje fan ferskate soarten spesjale easken fan net-standert dompelmotor en pomp. Produktimplementaasjenormen: GB/T2816-2014 "goed dompelpomp", GB / T2818-2014 "goed dompelbere asynchrone motor". WhatsApp: 17855846335
PDF DOWNLOAD
Details
Tags
 
produktoersjoech

The motor is filled with clean water, and the special wear-resistant sleeve with water as the medium (no grease and no pollution). The impeller group is made of stainless steel 304, which is corrosion-resistant, wear-resistant, energy-saving and environmentally friendly, suitable for extracting underground drinking water, fountains, seawater, and can also be used for beverage, food, petrochemical industry, marine fire protection, etc.

 

 
Betingsten fan gebrûk

1, Netzteil: trije-fase AC 380V (tolerânsje + / - 5%), 50HZ (tolerânsje + / - 1%).

2, wetterkwaliteit:

(1) wettertemperatuer is net heger as 20 °C;

(2) fêste ûnreinheden ynhâld (massa ratio) is net grutter as 0,01%;

(3) PH wearde (pH) 6,5-8,5;

(4) wetterstof sulfide ynhâld is net grutter as 1.5mg / L;

(5) chloride ion ynhâld is net grutter as 400mg / L.

3, de motor is sletten of mei wetter fol wiete struktuer, foardat gebrûk de ûnderdompele motor holte moat wêze fol mei skjin wetter, foar te kommen falske fol, en dan strak it wetter ynjeksje, lucht release bouten, oars net tastien te brûken

4, dompelpomp moat folslein ûnderdompele wurde yn it wetter, de dûkdjipte is net grutter as 70m, de boaiem fan 'e dompelpomp fan' e boaiem fan 'e put is net minder as 3m.

5, de put wetter stream moat wêze kinne om te foldwaan oan de submersible pomp wetter útfier en trochgeande operaasje, de submersible pomp wetter útfier moat wurde regele op 0,7 - 1,2 kear de rated stream.

6, de put moat rjocht wêze, de dompelpomp kin net brûkt wurde of dumpt, allinich fertikaal gebrûk.

7, de dompelpomp moat wurde matched mei de kabel neffens de easken, en de eksterne overload beskerming apparaat. 8, de pomp is strang ferbean sûnder wetter no-load test masine

 

 
Model Meaning

 
Partial Model Reference

4SPstainless steel submersible pumps

Model

Streame

m³/h

Holle

(m)

Motor

Krêft

(KW)

Ienheid

diameter

(mm)

diameter (mm)

4SP2-92/23

2

92

1,1 kw

 

105

110以上

4SP2-112/28

112

1,5 kw

4SP2-132/33

132

1,5 kw

4SP2-160/40

160

2,2 kw

4SP2-192/48

192

2,2 kw

4SP2-220/55

220

3 kw

4SP3-64/15

3

64

1,1 kw

105

110

以上

4SP3-77/18

77

1,1 kw

4SP3-94/22

94

1,5 kw

4SP3-107/25

107

1,5 kw

4SP3-137/32

137

2,2 kw

4SP3-167/39

167

3 kw

4SP3-188/44

188

3 kw

4SP3-222/52

222

4 kw

4SP5-48/12

5

48

1,1 kw

105

110

以上

4SP5-68/17

68

1,5 kw

4SP5-88/22

88

2,2 kw

4SP5-100/25

100

2,2 kw

4SP5-132/33

132

3 kw

4SP5-152/38

152

4 kW

4SP5-160/40

160

4 kw

4SP5-176/44

176

4 kw

4SP5-208/52

208

5,5 kw

4SP5-260/65

260

7,5 kW

4SP5-300/75

300

7,5 kW

 

4SPstainless steel submersible pumps

Model

Streame

m³/h

Holle

(m)

Motor

Krêft

(KW)

Ienheid

diameter

(mm)

diameter (mm)

4SP8-30/7

8

30

1.1KW

105

110以上

4SP8-43/10

43

1.5KW

4SP8-51/12

51

2.2KW

4SP8-60/14

60

2.2KW

4SP8-77/18

77

3KW

4SP8-90/21

90

4 kW

4SP8-103/24

103

4 kW

4SP8-129/30

129

5,5 kW

4SP8-150/35

150

5,5 kW

4SP8-172/40

172

7,5 kW

4SP8-189/44

189

7,5 kW

4SP8-210/50

210

7,5 kW

4SP14-22/5

14

22

1.5KW

105

110以上

4SP14-31/7

31

2.2KW

4SP14-44/10

44

3KW

4SP14-57/13

57

4 kW

4SP14-66/15

66

5,5 kW

4SP14-79/18

79

5,5 kW

4SP14-93/21

93

7,5 kW

4SP14-110/25

110

7,5 kW

 

5SPstainless steel submersible pumps

Model

Streame

m³/h

Holle

(m)

Motor

Krêft

(KW)

Ienheid

diameter

(mm)

diameter (mm)

5SP8-50/6

8

50

2,2 kw

130

135

5SP8-75/9

75

 

3 kw

5SP8-100/12

100

4 kw

5SP8-133/16

133

5,5 kw

5SP8-191/23

191

9 ,2kw

5SP8-224/27

224

11 kw

5SP8-274/33

274

13 kw

5SP8-324/39

324

15 kw

5SP8-373/45

373

18,5 kw

5SP10-36/4

10

36

2,2 kw

130

135

5SP10-45/5

45

3 kw

5SP10-63/7

63

4 kw

5SP10-90/10

90

5,5 kw

5SP10-126/14

126

7 ,5kw

5SP10-153/17

153

9 ,2kw

5SP10-189/21

189

11 kw

5SP10-225/25

225

13 kw

5SP10-261/29

261

15 kw

5SP10-324/36

324

18,5 kw

5SP10-360/40

360

22 kw

 

5SPstainless steel submersible pumps

Model

Streame

m³/h

Holle

(m)

Motor

Krêft

(KW)

Ienheid

diameter

(mm)

diameter (mm)

5SP15-25/3

15

25

2.2KW

130

135

5SP15-42/5

42

3KW

5SP15-59/7

59

4 kW

5SP15-76/9

76

5,5 kW

5SP15-93/11

93

7,5 kW

5SP15-110/13

110

7,5 kW

5SP15-127/15

127

9.2KW

5SP15-144/17

144

11 kW

5SP15-161/19

161

11 kW

5SP15-178/21

178

13 KW

5SP15-195/23

195

15 kW

5SP15-255/30

255

18,5 kW

5SP15-300/35

300

22KW

5SP15-340/40

340

25 kW

5SP20-23/3

20

23

2,2 kw

130

135

5SP20-30/4

30

3 kw

5SP20-38/5

38

4 kw

5SP20-53/7

53

5,5 kw

5SP20-75/10

75

7 ,5kw

5SP20-90/12

90

9 ,2kw

5SP20-113/15

113

11 kw

5SP20-135/18

135

13 kw

5SP20-158/21

158

15 kw

5SP20-195/26

195

18,5 kw

5SP20-225/30

225

22 kw

5SP20-270/36

270

25 kW

5SP20-310/42

310

30 kW

5SP25-23/3

25

23

2,2 kw

130

135

5SP25-30/4

30

3 kw

5SP25-38/5

38

4 kw

5SP25-45/6

45

5,5 kw

5SP25-68/9

68

7 ,5kw

5SP25-83/11

83

9 ,2kw

5SP25-98/13

98

11 kw

5SP25-120/16

120

13 kw

5SP25-143/19

143

15 kw

5SP25-173/23

173

18,5 kw

5SP25-210/28

210

22 kw

5SP25-235/32

235

25 kW

5SP25-285/39

285

30 kW

 

5SPstainless steel submersible pumps

Model

Streame

m³/h

Holle

(m)

Motor

Krêft

(KW)

Ienheid

diameter

(mm)

diameter (mm)

5SP30-14/2

30

14

2.2KW

130

135

5SP30-21/3

21

3KW

5SP30-28/4

28

4 kW

5SP30-35/5

35

5,5 kW

5SP30-42/6

42

5,5 kW

5SP30-49/7

49

7,5 kW

5SP30-56/8

56

7,5 kW

5SP30-63/9

63

9 ,2kw

5SP30-70/10

70

9 ,2kw

5SP30-77/11

77

11 kw

5SP30-84/12

84

11 kw

5SP30-91/13

91

13 kw

5SP30-98/14

98

13 kw

5SP30-105/15

105

15 kw

5SP30-112/16

112

15 kw

5SP30-136/20

136

18,5 kW

5SP30-154/22

154

22KW

5SP30-172/25

172

25 kW

5SP30-210/30

210

30 kW

 

6SPstainless steel submersible pumps

Model

Streame

m³/h

Holle

(m)

Motor

Krêft

(KW)

Ienheid

diameter

(mm)

 

diameter

(mm)

6SP10-35/4

10

35

2,2 kw

143

150

6SP10-53/6

53

3 kw

6SP10-70/8

70

4 kw

6SP10-96/11

96

5,5 kw

6SP10-131/15

131

7 ,5kw

6SP10-157/18

157

9 ,2kw

6SP10-192/22

192

11 kw

6SP10-226/26

226

13 kw

6SP10-261/30

261

15 kw

6SP10-322/37

322

18,5 kw

6SP17-40/5

17

40

3 kw

143

150

6SP17-48/6

48

4 kw

6SP17-72/9

72

5,5 kw

6SP17-96/12

96

7 ,5kw

6SP17-128/16

128

9 ,2kw

6SP17-152/19

152

11 kw

6SP17-168/21

168

13 kw

6SP17-208/26

208

15 kw

6SP17-256/32

256

18,5 kw

6SP17-312/39

312

22 kw

6SP20-37/4

20

37

3 kw

143

150

6SP20-43/5

43

4 kw

6SP20-68/8

68

5,5 kw

6SP20-85/10

85

7 ,5kw

6SP20-111/13

111

9 ,2kw

6SP20-136/16

136

11 kw

6SP20-162/19

162

13 kw

6SP20-196/23

196

15 kw

6SP20-230/27

230

18,5 kw

6SP20-281/33

281

22 kw

6SP20-332/39

332

25 kw

 

6SPstainless steel submersible pumps

Model

Streame

m³/h

Holle

(m)

Motor

Krêft

(KW)

Ienheid

diameter

(mm)

diameter (mm)

6SP25-33/4

25

33

4 kw

143

150

6SP25-49/6

49

5,5 kw

6SP25-74/9

74

7 ,5kw

6SP25-90/11

90

9 ,2kw

6SP25-106/13

106

11 kw

6SP25-122/15

122

13 kw

6SP25-147/18

147

15 kw

6SP25-180/22

180

18,5 kw

6SP25-212/26

212

22 kw

6SP25-245/30

245

25 kw

6SP25-293/36

293

30 kw

6SP25-325/40

325

37kw

6SP25-360/44

360

37kw

6SP25-390/48

390

45kw

6SP25-431/53

431

45kw

6SP30-23/3

30

23

3 kw

143

150

6SP30-30/4

30

4 kw

6SP30-38/5

38

5,5 kw

6SP30-53/7

53

7 ,5kw

6SP30-75/10

75

9 ,2kw

6SP30-90/12

90

11 kw

6SP30-105/14

105

13 kw

6SP30-120/16

120

15 kw

6SP30-150/20

150

18,5 kw

6SP30-188/25

188

22 kw

6SP30-210/28

210

25 kw

6SP30-255/34

255

30 kw

6SP30-293/25

293

37kw

6SP30-351/30

351

45kw

6SP30-410/35

410

55kw

6SP30-468/40

468

63kw

 

6SPstainless steel submersible pumps

Model

Streame

m³/h

Holle

(m)

Motor

Krêft

(KW)

Ienheid

diameter

(mm)

diameter (mm)

6SP35-20/2

35

20

3 kw

143

150

6SP35-30/3

30

4 kw

6SP35-40/4

40

5,5 kw

6SP35-51/5

51

7 ,5kw

6SP35-61/6

61

9 ,2kw

6SP35-72/7

72

11 kw

6SP35-82/8

82

13 kw

6SP35-102/10

102

15 kw

6SP35-123/12

123

18,5 kw

6SP35-143/14

143

22 kw

6SP35-164/16

164

25 kw

6SP35-204/20

204

30 kw

6SP35-255/25

255

37kw

6SP35-306/30

306

45kw

6SP35-360/35

360

 

6SP35-410/40

410

63kw

6SP40-18/2

40

18

3 kw

143

150

6SP40-27/3

27

5,5 kw

6SP40-45/5

45

7 ,5kw

6SP40-55/6

55

 

6SP40-64/7

64

11 kw

6SP40-74/8

74

 

6SP40-92/10

92

15 kw

6SP40-110/12

110

18,5 kw

6SP40-129/14

129

22 kw

6SP40-145/16

145

25 kw

6SP40-184/20

184

30 kw

6SP40-220/24

220

37kw

6SP40-320/35

320

55kw

6SP40-360/40

360

63kw

6SP46-17/2

46

17

3 kw

143

150

6SP46-25/3

25

5,5 kw

6SP46-45/5

45

7 ,5kw

6SP46-54/6

54

9 ,2kw

6SP46-63/7

63

kw

6SP46-72/8

72

13 kw

6SP46-90/10

90

15 kw

6SP46-108/12

108

18,5 kw

6SP46-126/14

126

22 kw

6SP46-144/16

144

25 kw

6SP46-180/20

180

30 kw

6SP46-207/23

207

37kw

6SP46-252/28

252

45kw

6SP46-270/30

270

45kw

6SP46-315/35

315

55kw

6SP46-360/40

360

63kw

 

6SPstainless steel submersible pumps

Model

Streame

m³/h

Head (m)

Motor

Krêft

(KW)

Ienheid

diameter

(mm)

diameter (mm)

6SP50-8/1

50

8

1,5 kw

143

150

6SP50-17/2

17

3 kw

6SP50-25/3

25

5,5 kw

6SP50-34/4

34

7 ,5kw

6SP50-43/5

43

7 ,5kw

6SP50-51/6

51

9 ,2kw

6SP50-60/7

60

11 kw

6SP50-68/8

68

13 kw

6SP50-86/10

86

15 kw

6SP50-103/12

103

18,5 kw

6SP50-120/14

120

22 kw

6SP50-137/16

137

25 kw

6SP50-154/18

154

30 kw

6SP50-172/20

172

30 kw

6SP50-206/24

206

37kw

6SP50-258/30

258

45kw

6SP50-300/35

300

55kw

6SP50-344/40

344

63kw

6SP60-15/2

60

15

4 kw

143

150

6SP60-23/3

23

5,5 kw

6SP60-30/4

30

7 ,5kw

6SP60-38/5

38

9 ,2kw

6SP60-45/6

45

 

6SP60-53/7

53

13 kw

6SP60-60/8

60

15 kw

6SP60-68/9

68

18,5 kw

6SP60-83/11

83

22 kw

6SP60-105/14

105

25 kw

6SP60-120/16

120

30 kw

6SP60-150/18

150

37kw

6SP60-200/24

200

45kw

6SP60-232/28

232

55kw

6SP60-265/32

265

63kw

6SP70-6/1

70

6

2,2 kw

143

150

6SP70-12/2

12

4 kw

6SP70-19/3

19

5,5 kw

6SP70-25/4

25

7 ,5kw

6SP70-32/5

32

9 ,2kw

6SP70-38/6

38

11 kw

6SP70-51/8

51

15 kw

6SP70-58/9

58

18,5 kw

6SP70-64/10

64

18,5 kw

6SP70-70/11

70

22 kw

6SP70-77/12

77

22 kw

6SP70-84/13

84

25 kw

6SP70-90/14

90

25 kw

6SP70-97/15

97

30 kw

6SP70-103/16

103

30 kw

6SP70-116/18

116

37kw

6SP70-128/20

128

37kw

6SP70-155/24

155

45kw

6SP70-180/28

180

55kw

6SP70-210/32

210

63kw

 

8SPstainless steel submersible pumps

Model

Streame

m³/h

Holle

(m)

Motor

Krêft

(KW)

Ienheid

diameter

(mm)

diameter (mm)

8SP77-12/1

77

12

4 kW

184

200

8SP77-25/2

25

7,5 kW

8SP77-37/3

37

11 kW

8SP77-50/4

50

15 kW

8SP77-61/5

61

18,5 kW

8SP77-74/6

74

22KW

8SP77-86/7

86

26KW

8SP77-99/8

99

30 kW

8SP77-123/10

123

37KW

8SP77-148/12

148

45KW

8SP77-185/15

185

55KW

8SP77-210/17

210

63KW

8SP77-246/20

246

75KW

8SP95-12/1

95

12

5,5 kW

184

200

8SP95-24/2

24

9.2KW

8SP95-36/3

36

13 KW

8SP95-48/4

48

18,5 kW

8SP95-60/5

60

22KW

8SP95-72/6

72

26KW

8SP95-96/8

96

37KW

8SP95-120/10

120

45KW

8SP95-132/11

132

55KW

8SP95-144/12

144

55KW

8SP95-168/14

168

63KW

8SP95-193/16

193

75KW

8SP95-240/20

240

93KW

8SP120-12

120

12

7,5 kW

184

200

8SP120-24

24

13 KW

8SP120-36

36

18,5 kW

8SP120-48

48

22KW

8SP120-60

60

30 kW

8SP120-72

72

37KW

8SP120-84

84

45KW

8SP120-96

96

55KW

8SP120-108

108

55KW

8SP120-120

120

63KW

 

10SPstainless steel submersible pumps

Model

Streame

m³/h

Holle

(m)

Motor

Krêft

(KW)

Ienheid

diameter

(mm)

diameter (mm)

10SP125-20

125

20

11 kW

233

250

10SP125-40

40

22KW

10SP125-60

60

30 kW

10SP125-80

80

45KW

10SP125-100

100

55KW

10SP125-120

120

63KW

10SP125-140

140

75KW

10SP125-160

160

93KW

10SP125-180

180

93KW

10SP160-20

160

20

13 KW

233

250

10SP160-40

40

26KW

10SP160-60

60

37KW

10SP160-80

80

55KW

10SP160-100

100

63KW

10SP160-120

120

75KW

10SP160-140

140

93KW

10SP160-160

160

93KW

10SP160-180

180

110KW

 

 
Feiligens foarsoarchsmaatregels

1, well submersible pump for clean water pump, prohibit the new well, pumping sediment and muddy water,

2, well water pump voltage grade of 380/50HZ, the use of other voltage grades of submersible motors need to be customized. The underground cable must use waterproof cable, must be equipped with starting equipment, such as distribution box, start not ready should have commonly used motor comprehensive protection function, such as short circuit overload protection, phase protection, undervoltage protection, grounding protection, idling protection, in case of abnormal conditions, the protection device should be timely action trip.

3, the installation and use of the pump must be reliably grounded, prohibit the push and pull switch when the hands and feet are wet, the installation and maintenance of the pump must be cut off the power supply, the use of the pump place to set up "to prevent electric shock" obvious signs:

4, down the well or before installation, the motor cavity must be filled with distilled water or non-corrosive clean cold boiling water, tighten the / water bolt, the pump on the ground test run, must be to the pump chamber water lubrication rubber bearings, instant start not more than a second, see whether the steering is the same as the steering instructions. When the pump is upright, pay attention to safety, prevent overturning injury.

5, strikt neffens de bepalingen fan 'e pomplift, streamberik fan gebrûk, om lege trochstreaming of hege lift pompekrêft te foarkommen, de thrust bearing en oare dielen fan' e wearze, de motor overload ferbaarnd

6, after the pump down the well, the measurement of the motor to the ground insulation resistance should not be less than 100M, after the start to observe the voltage and current, check the motor winding insulation, whether in line with the requirements; pump storage location temperature if less than freezing point, should be dry the motor cavity water, prevent the motor cavity water ice damage caused by low temperature.

 

 
Ûnderhâld en ûnderhâld

 This product is a submersible pump. After installation, the insulation resistance and three-phase continuity should be rechecked to ensure the connection between the instrument and the starting equipment.If everything is normal, the machine can be tested. After starting, observe whether the readings of the instruments are correct. If the rated voltage and current beyond the nameplate, pay attention to whether the pump has noise or vibration.If everything is normal, it can be put into operation. After the first operation for four hours, the pump should be closed and the motor thermal insulation resistance test should be carried out quickly, and the value should not be less than 0.5 megaohm. After stopping the pump, it is necessary to restart it at an interval of five minutes to prevent the water column in the pipeline from completely reversing, causing excessive current and burning the motor. After normal operation, the power supply voltage, running current and insulation resistance should be checked regularly. If abnormal conditions are found, the machine should be stopped immediately to troubleshoot. When disassembling, it is necessary to untie the cable rope, remove the pipeline part, remove the line protection plate, and dry all the water in the motor cavity side by side. The disassembly sequence includes taking off the filter element, loosening the bolt of the coupling fixed to the motor shaft, unscrewing the bolt connecting the water inlet and the motor, separating the pump and the motor (pay attention to keeping the unit level when separating to avoid bending the pump shaft) and other steps. For motor disassembly, it is necessary to remove the nut, base, shaft head lock nut, thrust plate, key, lower guide, bearing seat, screw (pull rod screw), take out the rotor, and finally take out the connection part and upper guide bearing seat. When assembling the unit, it is necessary to clean the rust and dirt of each part, apply sealant and assemble in reverse order according to the disassembly. When running once a year or the operation time is less than one year but the immersion time is two years, it is necessary to disassemble and inspect in accordance with the provisions and replace the worn parts. Storage needs to empty the water in the motor cavity, pay attention to the anticorrosive wire mesh plate and tie the cable, stored in a room with a temperature below 40 DEG C and no corrosive substances and gases, and pay attention to rust prevention when not used for a long time.

 

 
Applikaasje senario

01 Djippe boarne wetter yntak

02 Hege wetterfoarsjenning

03 berch wetterfoarsjenning 

04 toer wetter

05 Agraryske yrrigaasje

06 tún yrrigaasje

07 rivier wetter yntak

08 húshâldlik wetter

 

As jo ​​ynteressearre binne yn ús produkten, kinne jo kieze in ferlitte jo ynformaasje hjir, en wy sille yn kontakt mei jo koart.


Skriuw jo berjocht hjir en stjoer it nei ús

As jo ​​ynteressearre binne yn ús produkten, kinne jo kieze in ferlitte jo ynformaasje hjir, en wy sille yn kontakt mei jo koart.


fyFrisian