The motor winding adopts special water-resistant wire for frequency conversion winding, which has excellent characteristics such as high frequency stamping resistance, pulse peak voltage stamping resistance and high temperature aging resistance. The frequency conversion winding design ensures the long-term stable conversion operation of the motor between 1HZ-50HZ, making the frequency conversion deep well pump more energy saving and longer service life.
The product is supplied by three-phase AC 380V (tolerance ± 5%), 50HZ (tolerance ± 1%). Applicable water quality conditions include water temperature not exceeding 20 °C, solid impurities content (mass ratio) is not greater than 0.01%, PH value (pH) is 6.5-8.5, hydrogen sulfide content is not more than 1.5mg/L, chloride ion content is not more than 400mg/L. The motor adopts closed or water-filled wet structure. Before use, the internal chamber needs to be filled with clean water to prevent virtual filling. The pump needs to be completely immersed in water, the penetration depth shall not exceed 70m, and the distance from the bottom of the well shall not be less than 3m. The water inlet of the well shall meet the water output and continuous operation requirements of the pump, and the output of the pump shall be controlled at 0.7-1.2 times of the rated flow. The pump shall be used vertically, and the pump must be matched with the cable according to the requirements and equipped with external overload protection device. It is strictly prohibited to conduct no-load test of the pump, and it is necessary to avoid operation without water.
Mudellu | flussu (m3/h) | Capu (m) |
Rotatingspeed(change/point) | Pompa à acqua (%) | Outlet diamitru (mm) |
Applicabile bè diamitru (mm) |
Classificatu putenza (KW) |
Classificatu tensione (V) |
Classificatu currente (A) |
efficienza di u mutore (%) | factor di putenza cosφ | Unità Dimensione massima radiale (mm) |
Rimarca | |||||||||
150QJ5-100 | 5 | 100 | 2850 | 58 | 40 | 150 | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ5-150 | 5 | 150 | 2850 | 58 | 40 | 150 sopra | 4 | 380 | 10.25 | 75.0 | 0.79 | 143 | ||||||||||
150QJ5-200 | 200 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ5-250 | 250 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ5-300 | 300 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ10-50 | 10 | 50 | 2850 | 63 | 50 | 150sopra | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ10-66 | 66 | 4 | 10.25 | 75.0 | 0.79 | |||||||||||||||||
150QJ10-78 | 78 | 4 | 10.25 | 75.0 | 0.79 | |||||||||||||||||
150QJ10-84 | 84 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ10-91 | 91 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ10-100 | 100 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ10-128 | 128 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ10-150 | 150 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ10-200 | 200 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ10-250 | 250 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ10-300 | 300 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ15-33 | 15 | 33 | 2850 | 63 | 50 | 150sopra | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ15-42 | 42 | 4 | 10.25 | 75.0 | 0.79 | |||||||||||||||||
150QJ15-50 | 50 | 4 | 10.25 | 75.0 | 0.79 | |||||||||||||||||
150QJ15-60 | 60 | 5.5 | 13.74 | 76 | 0.8 | |||||||||||||||||
150QJ15-65 | 65 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ15-72 | 72 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ15-81 | 81 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ15-90 | 90 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ15-98 | 98 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ15-106 | 106 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ15-114 | 114 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ15-130 | 130 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ15-146 | 146 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ15-162 | 162 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ15-180 | 180 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ20-26 | 20 | 26 | 2850 | 64 | 50 | 150sopra | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ20-33 | 33 | 3 | 7.9 | 74.0 | 0.78 | |||||||||||||||||
150QJ20-39 | 20 | 39 | 2850 | 64 | 50 | 150sopra | 4 | 380 | 10.25 | 75.0 | 0.79 | 143 | ||||||||||
150QJ20-52 | 52 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ20-65 | 65 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ20-78 | 78 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ20-91 | 91 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ20-98 | 98 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ20-104 | 104 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ20-111 | 111 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ20-130 | 130 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ20-143 | 143 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ20-156 | 156 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ20-182 | 182 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ25-24 | 25 | 24 | 2850 | 64 | 65 | 150sopra | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ25-32 | 32 | 4 | 10.25 | 75.0 | 0.79 | |||||||||||||||||
150QJ25-40 | 40 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ25-48 | 48 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ25-56 | 56 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ25-64 | 64 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ25-72 | 72 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ25-77 | 77 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ25-84 | 84 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ25-96 | 96 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ25-104 | 104 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ25-110 | 110 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ25-120 | 120 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ25-128 | 128 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ25-136 | 136 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ25-154 | 154 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ32-18 | 32 | 18 | 2850 | 66 | 80 | 150sopra | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ32-24 | 24 | 4 | 10.25 | 75.0 | 0.79 | |||||||||||||||||
150QJ32-30 | 30 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ32-36 | 36 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ32-42 | 32 | 42 | 2850 | 66 | 80 | 150sopra | 7.5 | 380 | 18.5 | 77.0 | 0.8 | 143 | ||||||||||
150QJ32-54 | 54 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ32-66 | 66 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ32-72 | 72 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ32-84 | 84 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ32-90 | 90 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ32-96 | 96 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ32-114 | 114 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ40-16 | 40 | 16 | 2850 | 66 | 80 | 150sopra | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ40-24 | 24 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ40-30 | 30 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ40-40 | 40 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ40-48 | 48 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ40-56 | 56 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ40-64 | 64 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ40-72 | 72 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ40-80 | 80 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ40-96 | 96 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ50-16 | 50 | 16 | 2850 | 65 | 80 | 150sopra | 4 | 380 | 10.25 | 75.0 | 0.79 | 143 | ||||||||||
150QJ50-22 | 22 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ50-28 | 28 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ50-34 | 34 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ50-40 | 40 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ50-46 | 46 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ50-52 | 52 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ50-57 | 57 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ50-74 | 74 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ50-80 | 80 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ63-12 | 63 | 12 | 2850 | 60 | 80 | 150sopra | 4 | 380 | 10.25 | 75.0 | 0.79 | 143 | ||||||||||
150QJ63-18 | 18 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ63-30 | 30 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ63-36 | 36 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ63-42 | 63 | 42 | 2850 | 60 | 80 | 150sopra | 13 | 380 | 30.87 | 79.0 | 0.81 | 143 | ||||||||||
150QJ63-48 | 48 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ63-54 | 54 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ15-220 | 15 | 220 | 2850 | 50 | 150sopra | 18.5 | 380 | 43.12 | 143 | |||||||||||||
150QJ15-260 | 260 | 20 | 49.7 | |||||||||||||||||||
150QJ15-300 | 300 | 25 | 56.5 | |||||||||||||||||||
150QJ20-210 | 20 | 210 | 2850 | 50 | 150sopra | 20 | 380 | 49.7 | 143 | |||||||||||||
150QJ20-240 | 240 | 25 | 56.5 | |||||||||||||||||||
150QJ20-290 | 290 | 30 | 66.6 | |||||||||||||||||||
150QJ25-175 | 25 | 175 | 2850 | 65 | 150sopra | 20 | 49.7 | 143 | ||||||||||||||
150QJ25-200 | 200 | 30 | 66.6 | |||||||||||||||||||
150QJ25-290 | 290 | 37 | 82.1 | |||||||||||||||||||
150QJ32-120 | 32 | 120 | 2850 | 80 | 150sopra | 20 | 380 | 49.7 | 143 | |||||||||||||
150QJ32-132 | 132 | 25 | 56.5 | |||||||||||||||||||
150QJ32-156 | 156 | 30 | 66.6 | |||||||||||||||||||
150QJ32-190 | 190 | 37 | 82.1 | |||||||||||||||||||
150QJ32-240 | 240 | 45 | 96.9 | |||||||||||||||||||
150QJ40-110 | 40 | 110 | 2850 | 80 | 150sopra | 20 | 380 | 49.7 | 143 | |||||||||||||
150QJ40-121 | 121 | 25 | 56.5 | |||||||||||||||||||
150QJ40-143 | 143 | 30 | 66.6 | |||||||||||||||||||
150QJ40-176 | 176 | 37 | 82.1 | |||||||||||||||||||
150QJ40-220 | 220 | 45 | 96.9 | |||||||||||||||||||
150QJ50-100 | 50 | 100 | 2850 | 80 | 150sopra | 20 | 380 | 49.7 | 143 | |||||||||||||
150QJ50-110 | 110 | 25 | 56.5 | |||||||||||||||||||
150QJ50-130 | 130 | 30 | 66.6 | |||||||||||||||||||
150QJ50-160 | 160 | 37 | 82.1 | |||||||||||||||||||
150QJ50-200 | 200 | 45 | 96.9 |
This well submersible pump is a pump suitable for clean water. It is strictly prohibited to pump sediment and turbid water in new wells. The voltage level of the pump is 380/50HZ. Other voltage levels of the submersible motor need to be customized. Underground cables must be waterproof and must be equipped with starting equipment, such as distribution box, etc. The starting equipment should have common motor comprehensive protection functions, such as short circuit overload protection, phase loss protection, undervoltage protection, grounding protection and idling protection, etc. Under abnormal circumstances, the protection device should be tripped in time. In the process of installation and use, the pump must be reliably grounded. It is prohibited to push and pull the switch when the hands and feet are wet. The power must be cut off before installation and maintenance of the pump. The place where the pump is used must set up a clear "anti-electric shock" mark. Before going down the well or installation, the motor must be filled with distilled water or non-corrosive cool water, and the water inlet and outlet screws must be tightened. When testing the pump, water must be injected into the pump chamber to lubricate the rubber bearings. The instant start shall not exceed one second to check whether the direction is correct. It is necessary to pay attention to the safety of the pump when it is erected to prevent it from toppling and hurting people. Strictly in accordance with the provisions of the pump lift and flow range of use, so as not to have a large flow in the low lift pump or a large pull in the high lift, causing extreme wear of thrust bearings and other components, resulting in motor overload burn. After the pump into the well, the measurement of the motor and ground insulation resistance, not less than 100M. After the start, regular observation of voltage and current, and check whether the motor winding insulation meets the requirements; if the pump storage location temperature is below freezing, storage should discharge the water in the motor cavity, to prevent the water in the motor cavity due to low temperature and freeze damage the motor.
Breve introduzione di a struttura: a parte di a pompa hè cumposta principalmente da l'albero di a pompa, l'impeller, a cunchiglia di deviazione, i cuscinetti di gomma, u corpu di a valvola di cuntrollu (parti opzionali) è altri cumpunenti. A parte di u mutore hè principalmente cumpostu di basa, film di regulazione di pressione, cuscinetti di spinta, piastra di spinta, sediu di cuscinetti di guida inferiore, stator, rotore, sede di cuscinetti di guida superiore, anellu di sabbia, sezione di ingressu d'acqua, cable è altri cumpunenti.
E caratteristiche principali di u pruduttu include:
1.The motor is a water-filled wet submersible three-phase asynchronous motor, the motor cavity is full of clean water, used to cool the motor and lubricate the bearing, the pressure regulating film at the bottom of the motor is used to adjust the expansion and contraction pressure difference of the water inside the body caused by the change of the temperature rise of the motor.
2.In order to prevent the sand in the well water from entering the motor, the upper end of the motor shaft is equipped with two oil seals, and a sand ring is installed to form a sand prevention structure.
3.In order to prevent the pump shaft from running up when starting, the pump shaft and the motor shaft are connected by a coupling, and an upper thrust bearing is installed at the lower part of the motor.
4.The lubrication of the motor and the pump bearing is water lubrication.
5.The motor stator winding is made of high quality submersible motor winding wire, with high insulation performance.
6.The pump is designed by computer CAD, with simple structure and good technical performance.

(1) Preparazione prima di a stallazione:
1. Verificate s'ellu a pompa sommergibile risponde à e cundizioni d'utilizazione è u scopu specificate in u manuale.
2. Aduprà un oggettu pisanti cù un diametru uguali à u diametru massimu esterno di a pompa sommergibile, misurà s'ellu u diametru internu di u pozzu pò mette a pompa sommergibile, è misurà s'ellu a prufundità di u pozzu risponde à i requisiti di a stallazione.
3. Verificate se u pozzu hè pulitu è se l'acqua di u pozzu hè turbid. Ùn aduprate mai una pompa elettrica sommergibile per lavà u fangu è l'acqua di sabbia di a pompa welor per evità danni prematuri à a pompa elettrica sommergibile.
4. Verificate s'ellu a pusizione di a pinza di stallazione di u welhead hè adattata è s'ellu pò sustene a qualità di l'unità sana.
5. Verificate se i cumpunenti di a pompa sommergibile sò cumpleti è installati bè secondu u schema di assemblea in u manuale. Rimuove u screnu di filtru è girate l'accoppiamentu per vede s'ellu gira in modu flexible.
6. Unscrew the water screw and fillthe cavità di u mutore cù l'acqua pulita, micca currusiva (nota. assicuratevi di fillà), poi stringhje l'acqua. Dopu à 12 ore d'iniezione d'acqua, a resistenza d'insulazione di u mutore ùn deve esse menu di 150M Q quandu misurata cù una tavola agitante 500V.
7. Articulazione di u cable, tagliate una manica di gomma di 120 mm da una estremità di u cable in uscita è u cable currispundente cù un coltelli di l'electricista, poi scavalcate a lunghezza di i trè fili di core in una forma scalinata, sbucciate un core di rame di 20 mm, raschiate l'ossidu. capa nantu à l'esternu di u filu di ramu cù un cuteddu o un pannu di sabbia, è inserisci i dui estremità di u filu cunnessu in palirs.Dopu avè ligatu u stratu strettu cù un filu di ramu fino, saldate bè è fermamente, è sabbia di qualsiasi. burrs nantu à a superficia. Allora, per e trè articulazioni, aduprate una cinta d'insulazione di poliester per imballà in una manera semi stacked per trè laver. Avvolge e duie estremità di a strata di imballaggio strette cù un filu nyion, è dopu aduprate un metudu semi impilatu per imbulighjà a cinta per trè strati. Imbulighjate l'outtellayer cù una cinta d'insulazione d'alta pressione per trè strati. Infine, piegate i trè filamenti inseme è ripiglià ripetutamente per cinque strati cù cinta ad alta pressione. Ogni strata deve esse strettamente ligata, è l'interlayer joints deve esse strettu è fimm per impediscenu l'acqua di penetrazione è dannà l'insulation, Dopu l'imballaggio, immergete in acqua à a temperatura di l'ambienti di 20 'c per 12 ore, è misurà a resistenza di l'insulazione cù una tavola agitante. , chì ùn deve esse menu di 100M Ω
U schema di u prucessu di cablaggio di u cable attaccatu hè u seguitu:
8. Aduprate un multimetru per verificà se i fili trifasi sò cunnessi è se a resistenza DC hè apprussimatamente equilibrata.
9. Verificate s'ellu u circuitu è a capacità di u transformatore sò sovraccarichi, è dopu cunnette l'interruttore di prutezzione di sopracarga o l'equipaggiu di partenza. Vede a Tabella 2 per mudelli specifichi, è dopu Pour un bucket d'acqua in a pompa d'acqua da l'outlet di a pompa d'acqua per lubricate i cuscinetti di gomma in a pompa, è poi mette a pompa elettrica sommergibile in verticale è stabile. Start (micca più di una seconda) è verificate se a direzzione di a direzzione hè coherente cù u segnu di a direzzione. Se no, scambià ogni dui connettori di u cable trifase. Allora installate u filtru è preparate per falà u pozzu. Sè usatu in occasioni spiciali (cum'è fossi, fossi, fiumi, stagni, stagni, etc.), a pompa elettrica deve esse reliably grounded.
(2) Attrezzatura è arnesi d'installazione:
1. Un paru di catene di elevazione per più di duie tunnellate.
2. Un tripode cù una altezza verticale di micca menu di quattru metri.
3. Dui cordi pendenti (cordi di filu) chì ponu purtà un pesu di più di una tonna (pò suppurtà u pesu di un inseme cumpletu di pompe d'acqua).
4. Installa dui parigli di clamps (splints).
5. Chiavi, martelli, cacciavite, arnesi è strumenti elettrici, etc.
(3) Installazione di pompa elettrica:
1. U schema di stallazione di a pompa elettrica sommergibile hè indicatu in a Figura 2. I dimensioni di l'installazione specifiche sò mostrati in a Table 3 "Lista di dimensioni di l'installazione di a pompa elettrica submersible".
2. Pompe elettriche sommergibili cù una testa menu di 30 metri ponu esse isciutu direttamente in u pozzu utilizendu tubi è corde di filu o altre corde di canapa chì ponu suppurtà u pesu tutale di tutta a macchina, i tubi d'acqua è l'acqua in i tubi.
3. Pompe cù un capu di più di 30 metri utilizanu tubi d'acciaio, è a sequenza di stallazione hè a siguenti:
①Aduprate una pinza per chjappà l'estremità superiore di a parte di a pompa di l'acqua (u mutore è a pompa d'acqua sò stati cunnessi à questu mumentu), alzatelu cù una catena appesa, è legà lentamente in u pozzu finu à mette a pinza nantu à a testa di pozzu è sguassate a pinza. catena appesa.
② Aduprate un altru paru di pinze per chjappà una pipa, sollevala cù una catena pendente à 15 cm di distanza da a flange, è cala lentamente. Trà a flange di pipa è a flange di a pompa. Mettite u pad di gomma in u locu è stringhje a pipa è a pompa uniformemente cù bulloni, noci è rondelle di primavera.
③ Sollevate ligeramente a pompa sommergibile, sguassate a pinza à l'estremità superiore di a pompa d'acqua, attaccate fermamente u cable à a pipa di l'acqua cù una cinta di plastica, è ligate lentamente finu à chì a pinza hè posta à u pozzu.
④Usate u stessu metudu per ligà tutti i tubi d'acqua in u pozzu.
⑤Dopu chì u cable di uscita hè cunnessu à l'interruttore di cuntrollu, hè cunnessu à l'alimentazione trifase.
(4) Cose da nutà durante a stallazione:
1. Sè un fenomenu jamming hè trovu duranti lu prucessu di pumping, girari o tirà u pipa d'acqua à superà u puntu jamming. Se diverse misure ùn anu micca travagliatu, per piacè ùn forza micca a pompa per evità danni à a pompa elettrica sommergibile è u pozzu.
2. Duranti a stallazione, un pad di gomma deve esse postu à a flange di ogni pipa è strettu uniformemente.
3. Quandu a pompa di l'acqua hè calata in u pozzu, deve esse piazzata à mezu à u pipa di u pozzu per impedisce chì a pompa di currerà contru à u muru di u pozzu per un bellu pezzu, facendu chì a pompa vibrerà è u mutore per spazzà è brusgià. .
4. Determinate a prufundità di a pompa di l'acqua à u fondu di u pozzu secondu e cundizioni di sabbia è silt di u pozzu. Ùn enterrate micca a pompa in u fangu. A distanza da a pompa d'acqua à u fondu di u pozzu hè generalmente micca menu di 3 metri (vede a figura 2).
5. A prufundità di l'entrata di l'acqua di a pompa d'acqua ùn deve esse micca menu di 1-1,5 metri da u nivellu di l'acqua dinamica à u node di l'acqua (vede a figura 2). Altrimenti, i cuscinetti di a pompa d'acqua ponu esse facilmente dannati.
6. L'elevatore di a pompa d'acqua ùn pò esse troppu bassu. Altrimenti, una vàlvula di porta deve esse installata nantu à u pipeline di l'acqua di u pozzu per cuntrullà u flussu di a pompa à u puntu di flussu nominale per impedisce chì u mutore sia sovraccaricatu è brusgiatu per via di grandi flussi.
7. Quandu a pompa di l'acqua hè in funziunamentu, a pruduzzione di l'acqua deve esse cuntinuu è ancu, u currente deve esse stabile (sottu e cundizioni di travagliu nominali, in generale micca più di 10% di u currenti nominali), è ùn deve esse micca vibrazione o rumore. Se ci hè qualchì anormalità, a macchina deve esse fermata per scopre a causa è eliminà.
8. Quandu si stallanu, fate attente à a stallazione di u filu di terra di u mutore (vede a Figura 2). Quandu a pipa d'acqua hè una pipa d'acciaio, guidà da a pinza di u pozzu; quandu a pipa d'acqua hè una pipa di plastica, guidala da a marca di terra di a pompa elettrica.
1.submersible pump installation is complete, re-check the insulation resistance and three-phase conduction from the switch, check the instrument and start the equipment connection error, if there is no problem, can start the trial, after the start of the instrument indicating readings whether more than the nameplate stipulated rated voltage and current, observe the pump noise and vibration phenomenon, everything is normal can be put into operation.
2.pump operation for the first four hours, should be shut down quickly test the thermal insulation resistance of the motor, the value should not be less than 0.5 megaohm.
3.pump shutdown, should be started after an interval of five minutes, to prevent the water column in the pipe has not completely reflux caused by excessive motor current and burnout.
4.pump into normal operation, in order to prolong its service life, to check the supply voltage, working current and insulation resistance is normal, if found the following situation, should immediately shut down troubleshooting.
1.in the rated condition, the current is more than20%.
2.dynamic water level to the water inlet section, causing intermittent water.
3.submersible pump severe vibration or noise.
4.supply voltage is lower than 340 volts.
5.fuse burned out a phase.
6.water pipe damage.
7.motor to the thermal insulation resistance is less than 0.5 megaohm. 5. The product is a pump unit with easy disassembly function, with simple steps of disassembly, so that users can easily maintain and clean. The disassembly steps include unraveling the cable rope, taking down the pipeline part and the line protection plate, unloosening the water discharge bolt, excluding all the water in the motor chamber, removing the filter and loosening the coupling fixing screw fixing the motor shaft, unscrewing the bolt connecting the water inlet section and the motor, separating the pump and the motor (note that the unit should be leveled when separating to prevent the bending of the pump shaft), the disassembly sequence of the pump is: water inlet section, impeller, shunt shell, impeller, and cleaning the valve body. When disassembling the impeller, use special tools to loosen the conical sleeve fixing the impeller. In the whole disassembly process, avoid bending the pump shaft and damaging various parts. The disassembly process of the motor is: put the motor on the platform, and remove the nuts, base, shaft head lock nut, thrust plate, key, and lower guide rail from the bottom of the motor in order. Bearing seat, tie rod bolt, and then take out the rotor (be careful not to damage the wiring harness) and finally remove the connecting section and the upper guide bearing seat. Before assembling the unit, the rust and dirt of each part should be cleaned, and the sealant should be coated on each mating surface and fastener, and then the assembly should be carried out in reverse order according to the disassembly (the movement of the motor shaft after assembly is about 1 mm). After the assembly is completed, the coupling should be flexibly rotated, and then the filter should be put on for machine test. This pump unit is not only convenient and easy to use, but also has detailed instructions, which provides users with convenient maintenance experience. 6. Submersible electric pump every operation for one year, or less than one year but the diving time has reached two years, should be put out of the well according to Article 5 for disassembly and maintenance, and replace the worn parts.
1, mette l'acqua in a cavità di u mutore (in particulare in l'inguernu per impedisce chì u mutore si congela), è ligà bè u cable.
2, almacenà in una stanza interna senza sustanzi corrosivi è gasi, cù una temperatura sottu à 40 ° C.
3, usu à longu andà deve esse attentu à a prevenzione di ruggine di pompe sommergibili.
- Impeller
- A manica di l'arbre
- Manica di l'arbulu di gomma
-
Anellu di sigillatura
01 Ingestione d'acqua di pozzu prufonda
02 Fornitura d'acqua alta
03 supply d'acqua di muntagna
04 torre acqua
05 Irrigazione agricula
06 irrigazione di giardinu
07 acqua di u fiume
08 acqua domestica