The motor winding adopts special water-resistant wire for frequency conversion winding, which has excellent characteristics such as high frequency stamping resistance, pulse peak voltage stamping resistance and high temperature aging resistance. The frequency conversion winding design ensures the long-term stable conversion operation of the motor between 1HZ-50HZ, making the frequency conversion deep well pump more energy saving and longer service life.
The product is supplied by three-phase AC 380V (tolerance ± 5%), 50HZ (tolerance ± 1%). Applicable water quality conditions include water temperature not exceeding 20 °C, solid impurities content (mass ratio) is not greater than 0.01%, PH value (pH) is 6.5-8.5, hydrogen sulfide content is not more than 1.5mg/L, chloride ion content is not more than 400mg/L. The motor adopts closed or water-filled wet structure. Before use, the internal chamber needs to be filled with clean water to prevent virtual filling. The pump needs to be completely immersed in water, the penetration depth shall not exceed 70m, and the distance from the bottom of the well shall not be less than 3m. The water inlet of the well shall meet the water output and continuous operation requirements of the pump, and the output of the pump shall be controlled at 0.7-1.2 times of the rated flow. The pump shall be used vertically, and the pump must be matched with the cable according to the requirements and equipped with external overload protection device. It is strictly prohibited to conduct no-load test of the pump, and it is necessary to avoid operation without water.
ماڈل | بہاؤ (m3/h) | سر (m) |
Rotatingspeed(change/point) | پانی کا پمپ(٪) | آؤٹ لیٹ قطر (ملی میٹر) |
اچھی طرح سے قابل اطلاق قطر (ملی میٹر) |
درجہ بندی طاقت (KW) |
درجہ بندی وولٹیج (V) |
درجہ بندی موجودہ (A) |
موٹر کارکردگی (%) | پاور فیکٹرکوسφ | یونٹ ریڈیل زیادہ سے زیادہ سائز (ملی میٹر) |
تبصرہ | |||||||||
150QJ5-100 | 5 | 100 | 2850 | 58 | 40 | 150 | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ5-150 | 5 | 150 | 2850 | 58 | 40 | 150 اوپر | 4 | 380 | 10.25 | 75.0 | 0.79 | 143 | ||||||||||
150QJ5-200 | 200 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ5-250 | 250 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ5-300 | 300 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ10-50 | 10 | 50 | 2850 | 63 | 50 | 150اوپر | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ10-66 | 66 | 4 | 10.25 | 75.0 | 0.79 | |||||||||||||||||
150QJ10-78 | 78 | 4 | 10.25 | 75.0 | 0.79 | |||||||||||||||||
150QJ10-84 | 84 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ10-91 | 91 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ10-100 | 100 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ10-128 | 128 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ10-150 | 150 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ10-200 | 200 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ10-250 | 250 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ10-300 | 300 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ15-33 | 15 | 33 | 2850 | 63 | 50 | 150اوپر | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ15-42 | 42 | 4 | 10.25 | 75.0 | 0.79 | |||||||||||||||||
150QJ15-50 | 50 | 4 | 10.25 | 75.0 | 0.79 | |||||||||||||||||
150QJ15-60 | 60 | 5.5 | 13.74 | 76 | 0.8 | |||||||||||||||||
150QJ15-65 | 65 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ15-72 | 72 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ15-81 | 81 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ15-90 | 90 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ15-98 | 98 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ15-106 | 106 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ15-114 | 114 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ15-130 | 130 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ15-146 | 146 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ15-162 | 162 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ15-180 | 180 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ20-26 | 20 | 26 | 2850 | 64 | 50 | 150اوپر | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ20-33 | 33 | 3 | 7.9 | 74.0 | 0.78 | |||||||||||||||||
150QJ20-39 | 20 | 39 | 2850 | 64 | 50 | 150اوپر | 4 | 380 | 10.25 | 75.0 | 0.79 | 143 | ||||||||||
150QJ20-52 | 52 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ20-65 | 65 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ20-78 | 78 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ20-91 | 91 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ20-98 | 98 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ20-104 | 104 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ20-111 | 111 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ20-130 | 130 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ20-143 | 143 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ20-156 | 156 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ20-182 | 182 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ25-24 | 25 | 24 | 2850 | 64 | 65 | 150اوپر | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ25-32 | 32 | 4 | 10.25 | 75.0 | 0.79 | |||||||||||||||||
150QJ25-40 | 40 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ25-48 | 48 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ25-56 | 56 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ25-64 | 64 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ25-72 | 72 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ25-77 | 77 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ25-84 | 84 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ25-96 | 96 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ25-104 | 104 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ25-110 | 110 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ25-120 | 120 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ25-128 | 128 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ25-136 | 136 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ25-154 | 154 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ32-18 | 32 | 18 | 2850 | 66 | 80 | 150اوپر | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ32-24 | 24 | 4 | 10.25 | 75.0 | 0.79 | |||||||||||||||||
150QJ32-30 | 30 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ32-36 | 36 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ32-42 | 32 | 42 | 2850 | 66 | 80 | 150اوپر | 7.5 | 380 | 18.5 | 77.0 | 0.8 | 143 | ||||||||||
150QJ32-54 | 54 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ32-66 | 66 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ32-72 | 72 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ32-84 | 84 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ32-90 | 90 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ32-96 | 96 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ32-114 | 114 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ40-16 | 40 | 16 | 2850 | 66 | 80 | 150اوپر | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ40-24 | 24 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ40-30 | 30 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ40-40 | 40 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ40-48 | 48 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ40-56 | 56 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ40-64 | 64 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ40-72 | 72 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ40-80 | 80 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ40-96 | 96 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ50-16 | 50 | 16 | 2850 | 65 | 80 | 150اوپر | 4 | 380 | 10.25 | 75.0 | 0.79 | 143 | ||||||||||
150QJ50-22 | 22 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ50-28 | 28 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ50-34 | 34 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ50-40 | 40 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ50-46 | 46 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ50-52 | 52 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ50-57 | 57 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ50-74 | 74 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ50-80 | 80 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ63-12 | 63 | 12 | 2850 | 60 | 80 | 150اوپر | 4 | 380 | 10.25 | 75.0 | 0.79 | 143 | ||||||||||
150QJ63-18 | 18 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ63-30 | 30 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ63-36 | 36 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ63-42 | 63 | 42 | 2850 | 60 | 80 | 150اوپر | 13 | 380 | 30.87 | 79.0 | 0.81 | 143 | ||||||||||
150QJ63-48 | 48 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ63-54 | 54 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ15-220 | 15 | 220 | 2850 | 50 | 150اوپر | 18.5 | 380 | 43.12 | 143 | |||||||||||||
150QJ15-260 | 260 | 20 | 49.7 | |||||||||||||||||||
150QJ15-300 | 300 | 25 | 56.5 | |||||||||||||||||||
150QJ20-210 | 20 | 210 | 2850 | 50 | 150اوپر | 20 | 380 | 49.7 | 143 | |||||||||||||
150QJ20-240 | 240 | 25 | 56.5 | |||||||||||||||||||
150QJ20-290 | 290 | 30 | 66.6 | |||||||||||||||||||
150QJ25-175 | 25 | 175 | 2850 | 65 | 150اوپر | 20 | 49.7 | 143 | ||||||||||||||
150QJ25-200 | 200 | 30 | 66.6 | |||||||||||||||||||
150QJ25-290 | 290 | 37 | 82.1 | |||||||||||||||||||
150QJ32-120 | 32 | 120 | 2850 | 80 | 150اوپر | 20 | 380 | 49.7 | 143 | |||||||||||||
150QJ32-132 | 132 | 25 | 56.5 | |||||||||||||||||||
150QJ32-156 | 156 | 30 | 66.6 | |||||||||||||||||||
150QJ32-190 | 190 | 37 | 82.1 | |||||||||||||||||||
150QJ32-240 | 240 | 45 | 96.9 | |||||||||||||||||||
150QJ40-110 | 40 | 110 | 2850 | 80 | 150اوپر | 20 | 380 | 49.7 | 143 | |||||||||||||
150QJ40-121 | 121 | 25 | 56.5 | |||||||||||||||||||
150QJ40-143 | 143 | 30 | 66.6 | |||||||||||||||||||
150QJ40-176 | 176 | 37 | 82.1 | |||||||||||||||||||
150QJ40-220 | 220 | 45 | 96.9 | |||||||||||||||||||
150QJ50-100 | 50 | 100 | 2850 | 80 | 150اوپر | 20 | 380 | 49.7 | 143 | |||||||||||||
150QJ50-110 | 110 | 25 | 56.5 | |||||||||||||||||||
150QJ50-130 | 130 | 30 | 66.6 | |||||||||||||||||||
150QJ50-160 | 160 | 37 | 82.1 | |||||||||||||||||||
150QJ50-200 | 200 | 45 | 96.9 |
This well submersible pump is a pump suitable for clean water. It is strictly prohibited to pump sediment and turbid water in new wells. The voltage level of the pump is 380/50HZ. Other voltage levels of the submersible motor need to be customized. Underground cables must be waterproof and must be equipped with starting equipment, such as distribution box, etc. The starting equipment should have common motor comprehensive protection functions, such as short circuit overload protection, phase loss protection, undervoltage protection, grounding protection and idling protection, etc. Under abnormal circumstances, the protection device should be tripped in time. In the process of installation and use, the pump must be reliably grounded. It is prohibited to push and pull the switch when the hands and feet are wet. The power must be cut off before installation and maintenance of the pump. The place where the pump is used must set up a clear "anti-electric shock" mark. Before going down the well or installation, the motor must be filled with distilled water or non-corrosive cool water, and the water inlet and outlet screws must be tightened. When testing the pump, water must be injected into the pump chamber to lubricate the rubber bearings. The instant start shall not exceed one second to check whether the direction is correct. It is necessary to pay attention to the safety of the pump when it is erected to prevent it from toppling and hurting people. Strictly in accordance with the provisions of the pump lift and flow range of use, so as not to have a large flow in the low lift pump or a large pull in the high lift, causing extreme wear of thrust bearings and other components, resulting in motor overload burn. After the pump into the well, the measurement of the motor and ground insulation resistance, not less than 100M. After the start, regular observation of voltage and current, and check whether the motor winding insulation meets the requirements; if the pump storage location temperature is below freezing, storage should discharge the water in the motor cavity, to prevent the water in the motor cavity due to low temperature and freeze damage the motor.
ساخت کا مختصر تعارف: پمپ کا حصہ بنیادی طور پر پمپ شافٹ، امپیلر، ڈائیورژن شیل، ربڑ بیئرنگ، چیک والو باڈی (اختیاری حصے) اور دیگر اجزاء پر مشتمل ہوتا ہے۔ موٹر پارٹ بنیادی طور پر بیس، پریشر ریگولیٹنگ فلم، تھرسٹ بیئرنگ، تھرسٹ پلیٹ، لوئر گائیڈ بیئرنگ سیٹ، اسٹیٹر، روٹر، اپر گائیڈ بیئرنگ سیٹ، ریت کی انگوٹی، واٹر انلیٹ سیکشن، کیبل اور دیگر اجزاء پر مشتمل ہوتا ہے۔
مصنوعات کی اہم خصوصیات میں شامل ہیں:
1.The motor is a water-filled wet submersible three-phase asynchronous motor, the motor cavity is full of clean water, used to cool the motor and lubricate the bearing, the pressure regulating film at the bottom of the motor is used to adjust the expansion and contraction pressure difference of the water inside the body caused by the change of the temperature rise of the motor.
2.In order to prevent the sand in the well water from entering the motor, the upper end of the motor shaft is equipped with two oil seals, and a sand ring is installed to form a sand prevention structure.
3.In order to prevent the pump shaft from running up when starting, the pump shaft and the motor shaft are connected by a coupling, and an upper thrust bearing is installed at the lower part of the motor.
4.The lubrication of the motor and the pump bearing is water lubrication.
5.The motor stator winding is made of high quality submersible motor winding wire, with high insulation performance.
6.The pump is designed by computer CAD, with simple structure and good technical performance.

(1) تنصیب سے پہلے تیاری:
1. چیک کریں کہ کیا آبدوز پمپ دستی میں بیان کردہ استعمال کی شرائط اور دائرہ کار کو پورا کرتا ہے۔
2. سبمرسیبل پمپ کے زیادہ سے زیادہ بیرونی قطر کے برابر قطر والے بھاری آبییکٹ کا استعمال کرتے ہوئے، پیمائش کریں کہ کنویں کا اندرونی قطر سبمرسیبل پمپ کو فٹ کر سکتا ہے، اور پیمائش کریں کہ کنویں کی گہرائی تنصیب کی ضروریات کو پورا کرتی ہے۔
3. چیک کریں کہ کنواں صاف ہے اور کنویں کا پانی گندا ہے یا نہیں۔ سبمرسیبل الیکٹرک پمپ کو ویلور پمپ کیچڑ اور ریت کے پانی سے دھونے کے لیے کبھی بھی استعمال نہ کریں تاکہ آبدوز برقی پمپ کو قبل از وقت نقصان سے بچا جا سکے۔
4. چیک کریں کہ آیا ویلہیڈ انسٹالیشن کلیمپ کی پوزیشن مناسب ہے اور کیا یہ پوری یونٹ کے معیار کو برداشت کر سکتی ہے
5. چیک کریں کہ کیا آبدوز پمپ کے اجزاء مکمل ہیں اور مینول میں اسمبلی ڈایاگرام کے مطابق صحیح طریقے سے انسٹال ہیں فلٹر اسکرین کو ہٹا دیں اور کپلنگ کو گھمائیں تاکہ یہ معلوم ہو سکے کہ آیا یہ لچکدار طریقے سے گھومتا ہے
6. واٹر اسکرو کو کھولیں اور موٹر کیویٹی کو صاف، غیر corrosive پانی سے بھریں (نوٹ۔ اسے بھرنا یقینی بنائیں)، پھر واٹر اسکرو کو سخت کریں۔ پانی کے انجیکشن کے 12 گھنٹے کے بعد، جب 500V ہلانے والی میز کے ساتھ پیمائش کی جائے تو موٹر کی موصلیت کی مزاحمت 150M Q سے کم نہیں ہونی چاہیے۔
7. کیبل جوائنٹ، باہر جانے والی کیبل کے ایک سرے سے 120 ملی میٹر ربڑ کی آستین کو کاٹ دیں اور الیکٹریشن کے چاقو کے ساتھ مماثل کیبل تین بنیادی تاروں کی لمبائی کو قدموں والی شکل میں لڑکھڑا کر، 20 ملی میٹر کے تانبے کے کور کو چھیل کر، آکسائیڈ کو کھرچ دیں۔ چاقو یا ریت کے کپڑے سے تانبے کے تار کے باہر کی تہہ لگائیں، اور دونوں جڑے ہوئے تاروں کے سروں کو پیلر میں ڈالیں۔ باریک تانبے کے تار سے اس تہہ کو مضبوطی سے باندھنے کے بعد، اسے اچھی طرح اور مضبوطی سے ٹانکا لگائیں، اور کسی بھی طرح کی ریت۔ سطح پر burrs. اس کے بعد، تین جوڑوں کے لیے، پولی ویسٹر موصلیت کا ٹیپ استعمال کریں تاکہ انہیں تین لیورز کے لیے نیم اسٹیک شدہ انداز میں لپیٹیں۔ لپیٹنے والی پرت کے دونوں سروں کو نیون دھاگے سے مضبوطی سے لپیٹیں، اور پھر تین تہوں کے لیے ٹیپ کو لپیٹنے کے لیے نیم اسٹیک شدہ طریقہ استعمال کریں۔ آؤٹ لیئر کو تین تہوں کے لیے ہائی پریشر انسولیشن ٹیپ سے لپیٹیں۔ آخر میں، تین تاروں کو ایک ساتھ جوڑیں اور انہیں بار بار ہائی پریشر ٹیپ کے ساتھ پانچ پرتوں کے لیے لپیٹیں۔ ہر تہہ کو مضبوطی سے باندھنا چاہیے، اور موصلیت کو پانی میں گھسنے اور نقصان پہنچانے سے روکنے کے لیے انٹر لیئر جوڑ سخت اور مضبوط ہونا چاہیے، لپیٹنے کے بعد، کمرے کے درجہ حرارت پر 20 سینٹی گریڈ پر 12 گھنٹے تک پانی میں بھگو دیں، اور ہلنے والی میز سے موصلیت کی مزاحمت کی پیمائش کریں۔ ، جو 100M Ω سے کم نہیں ہونا چاہئے۔
منسلک کیبل وائرنگ کے عمل کا خاکہ مندرجہ ذیل ہے:
8. یہ چیک کرنے کے لیے ملٹی میٹر کا استعمال کریں کہ آیا تھری فیز تاریں جڑی ہوئی ہیں اور آیا ڈی سی مزاحمت تقریباً متوازن ہے۔
9. چیک کریں کہ آیا سرکٹ اور ٹرانسفارمر کی گنجائش اوورلوڈ ہے، اور پھر اوورلوڈ پروٹیکشن سوئچ یا شروع ہونے والے سامان کو جوڑیں۔ مخصوص ماڈلز کے لیے جدول 2 دیکھیں، اور پھر پمپ میں ربڑ کے بیرنگ کو چکنا کرنے کے لیے واٹر پمپ آؤٹ لیٹ سے پانی کے پمپ میں ایک بالٹی پانی ڈالیں، اور پھر آبدوز برقی پمپ کو سیدھا اور مستحکم رکھیں۔ اسٹارٹ کریں (ایک سیکنڈ سے زیادہ نہیں) اور چیک کریں کہ آیا اسٹیئرنگ کی سمت اسٹیئرنگ کے نشان کے مطابق ہے۔ اگر نہیں، تو تھری فیز کیبل کے کسی بھی دو کنیکٹرز کو تبدیل کریں۔ پھر فلٹر لگائیں اور کنویں کے نیچے جانے کی تیاری کریں۔ اگر خاص مواقع (جیسے گڑھے، گڑھے، ندی، تالاب، تالاب وغیرہ) میں استعمال کیا جائے تو الیکٹرک پمپ کو قابل اعتماد طریقے سے گراؤنڈ کیا جانا چاہیے۔
(2) تنصیب کا سامان اور اوزار:
1. دو ٹن سے زیادہ کے لیے لفٹنگ چینز کا ایک جوڑا۔
2. ایک تپائی جس کی عمودی اونچائی چار میٹر سے کم نہ ہو۔
3. دو لٹکنے والی رسیاں (تار کی رسیاں) جو ایک ٹن سے زیادہ وزن برداشت کر سکتی ہیں (پانی کے پمپ کے مکمل سیٹ کا وزن برداشت کر سکتی ہیں)۔
4. کلیمپ کے دو جوڑے (اسپلنٹ) لگائیں۔
5. رنچیں، ہتھوڑے، سکریو ڈرایور، برقی آلات اور آلات وغیرہ۔
(3) الیکٹرک پمپ کی تنصیب:
1. سبمرسیبل الیکٹرک پمپ کی تنصیب کا خاکہ شکل 2 میں دکھایا گیا ہے۔ مخصوص تنصیب کے طول و عرض جدول 3 میں "سبمرسیبل الیکٹرک پمپ کی تنصیب کے طول و عرض کی فہرست" میں دکھائے گئے ہیں۔
2. 30 میٹر سے کم سر والے آبدوز برقی پمپوں کو ہوز اور تار کی رسیوں یا دیگر بھنگ کی رسیوں کا استعمال کرتے ہوئے براہ راست کنویں میں لہرایا جا سکتا ہے جو پوری مشین، پانی کے پائپوں اور پائپوں میں پانی کا پورا وزن برداشت کر سکتے ہیں۔
3. 30 میٹر سے زیادہ سر والے پمپ سٹیل کے پائپ استعمال کرتے ہیں، اور تنصیب کی ترتیب حسب ذیل ہے:
①واٹر پمپ والے حصے کے اوپری سرے کو کلیمپ کرنے کے لیے کلیمپ کا استعمال کریں (موٹر اور واٹر پمپ اس وقت جڑے ہوئے ہیں)، اسے لٹکی ہوئی زنجیر کے ساتھ اٹھائیں، اور آہستہ آہستہ اسے کنویں میں باندھیں جب تک کہ کلیمپ کو کنویں کے سر پر نہ لگائیں اور اسے ہٹا دیں۔ پھانسی کی زنجیر.
② پائپ کو کلیمپ کرنے کے لیے کلیمپ کا دوسرا جوڑا استعمال کریں، اسے فلینج سے 15 سینٹی میٹر دور لٹکتی زنجیر کے ساتھ اٹھائیں، اور اسے آہستہ آہستہ نیچے کریں۔ پائپ فلینج اور پمپ فلینج کے درمیان ربڑ کے پیڈ کو جگہ پر رکھیں اور پائپ کو سخت کریں اور بولٹ، نٹ اور اسپرنگ واشر کے ساتھ یکساں طور پر پمپ کریں۔
③ آبدوز پمپ کو تھوڑا سا اٹھائیں، پانی کے پمپ کے اوپری سرے پر موجود کلیمپ کو ہٹائیں، کیبل کو پلاسٹک کے ٹیپ سے پانی کے پائپ سے مضبوطی سے باندھیں، اور اسے آہستہ آہستہ اس وقت تک باندھیں جب تک کہ کلیمپ کنویں کے سر پر نہ لگ جائے۔
④ پانی کے تمام پائپوں کو کنویں میں باندھنے کے لیے ایک ہی طریقہ استعمال کریں۔
⑤لیڈ آؤٹ کیبل کے کنٹرول سوئچ سے منسلک ہونے کے بعد، یہ تھری فیز پاور سپلائی سے منسلک ہے۔
(4) انسٹالیشن کے دوران نوٹ کرنے کی چیزیں:
1. اگر پمپنگ کے عمل کے دوران جیمنگ کا رجحان پایا جاتا ہے، تو پانی کے پائپ کو موڑ دیں یا کھینچیں تاکہ جیمنگ پوائنٹ پر قابو پایا جا سکے۔ اگر مختلف اقدامات اب بھی کام نہیں کرتے ہیں، تو براہ کرم آبدوز برقی پمپ اور کنویں کو پہنچنے والے نقصان سے بچنے کے لیے پمپ کو مجبور نہ کریں۔
2. تنصیب کے دوران، ربڑ کا پیڈ ہر پائپ کے کنارے پر رکھا جانا چاہیے اور یکساں طور پر سخت ہونا چاہیے۔
3. جب پانی کے پمپ کو کنویں میں اتارا جاتا ہے، تو اسے کنویں کے پائپ کے درمیان میں رکھنا چاہیے تاکہ پمپ کو زیادہ دیر تک کنویں کی دیوار کے خلاف چلنے سے روکا جا سکے، جس سے پمپ ہل جائے اور موٹر جھاڑو اور جل جائے۔ .
4. کنویں کی بہتی ریت اور گاد کے حالات کے مطابق کنویں کے نیچے تک پانی کے پمپ کی گہرائی کا تعین کریں۔ پمپ کو کیچڑ میں نہ دفن کریں۔ پانی کے پمپ سے کنویں کے نیچے تک کا فاصلہ عام طور پر 3 میٹر سے کم نہیں ہوتا ہے (شکل 2 دیکھیں)۔
5. پانی کے پمپ کی پانی کے اندراج کی گہرائی متحرک پانی کی سطح سے پانی کے انلیٹ نوڈ تک 1-1.5 میٹر سے کم نہیں ہونی چاہیے (تصویر 2 دیکھیں)۔ بصورت دیگر، پانی کے پمپ کے بیرنگ آسانی سے خراب ہو سکتے ہیں۔
6. واٹر پمپ کی لفٹ بہت کم نہیں ہو سکتی۔ بصورت دیگر، ویل ہیڈ واٹر پائپ لائن پر گیٹ والو نصب کرنے کی ضرورت ہے تاکہ درجہ بند بہاؤ پوائنٹ پر پمپ کے بہاؤ کو کنٹرول کیا جا سکے تاکہ موٹر کو اوور لوڈ ہونے اور زیادہ بہاؤ کی شرح کی وجہ سے جل جانے سے روکا جا سکے۔
7. جب پانی کا پمپ چل رہا ہو، پانی کی پیداوار مسلسل اور یکساں ہونی چاہیے، کرنٹ مستحکم ہونا چاہیے (درجہ بندی شدہ کام کے حالات کے تحت، عام طور پر ریٹیڈ کرنٹ کے 10% سے زیادہ نہیں)، اور کوئی کمپن یا شور نہیں ہونا چاہیے۔ اگر کوئی غیر معمولی بات ہو تو اس کی وجہ معلوم کرنے اور اسے ختم کرنے کے لیے مشین کو روک دینا چاہیے۔
8. انسٹال کرتے وقت، موٹر گراؤنڈنگ وائر کی ترتیب پر توجہ دیں (تصویر 2 دیکھیں)۔ جب پانی کا پائپ سٹیل کا پائپ ہو تو اسے ویل ہیڈ کلیمپ سے لیڈ کریں۔ جب پانی کا پائپ پلاسٹک کا پائپ ہو تو اسے الیکٹرک پمپ کے گراؤنڈ مارک سے لے جائیں۔
1.submersible pump installation is complete, re-check the insulation resistance and three-phase conduction from the switch, check the instrument and start the equipment connection error, if there is no problem, can start the trial, after the start of the instrument indicating readings whether more than the nameplate stipulated rated voltage and current, observe the pump noise and vibration phenomenon, everything is normal can be put into operation.
2.pump operation for the first four hours, should be shut down quickly test the thermal insulation resistance of the motor, the value should not be less than 0.5 megaohm.
3.pump shutdown, should be started after an interval of five minutes, to prevent the water column in the pipe has not completely reflux caused by excessive motor current and burnout.
4.pump into normal operation, in order to prolong its service life, to check the supply voltage, working current and insulation resistance is normal, if found the following situation, should immediately shut down troubleshooting.
1.in the rated condition, the current is more than20%.
2.dynamic water level to the water inlet section, causing intermittent water.
3.submersible pump severe vibration or noise.
4.supply voltage is lower than 340 volts.
5.fuse burned out a phase.
6.water pipe damage.
7.motor to the thermal insulation resistance is less than 0.5 megaohm. 5. The product is a pump unit with easy disassembly function, with simple steps of disassembly, so that users can easily maintain and clean. The disassembly steps include unraveling the cable rope, taking down the pipeline part and the line protection plate, unloosening the water discharge bolt, excluding all the water in the motor chamber, removing the filter and loosening the coupling fixing screw fixing the motor shaft, unscrewing the bolt connecting the water inlet section and the motor, separating the pump and the motor (note that the unit should be leveled when separating to prevent the bending of the pump shaft), the disassembly sequence of the pump is: water inlet section, impeller, shunt shell, impeller, and cleaning the valve body. When disassembling the impeller, use special tools to loosen the conical sleeve fixing the impeller. In the whole disassembly process, avoid bending the pump shaft and damaging various parts. The disassembly process of the motor is: put the motor on the platform, and remove the nuts, base, shaft head lock nut, thrust plate, key, and lower guide rail from the bottom of the motor in order. Bearing seat, tie rod bolt, and then take out the rotor (be careful not to damage the wiring harness) and finally remove the connecting section and the upper guide bearing seat. Before assembling the unit, the rust and dirt of each part should be cleaned, and the sealant should be coated on each mating surface and fastener, and then the assembly should be carried out in reverse order according to the disassembly (the movement of the motor shaft after assembly is about 1 mm). After the assembly is completed, the coupling should be flexibly rotated, and then the filter should be put on for machine test. This pump unit is not only convenient and easy to use, but also has detailed instructions, which provides users with convenient maintenance experience. 6. Submersible electric pump every operation for one year, or less than one year but the diving time has reached two years, should be put out of the well according to Article 5 for disassembly and maintenance, and replace the worn parts.
1، موٹر کیویٹی میں پانی نکال دیں (خاص طور پر سردیوں میں موٹر کو جمنے سے روکنے کے لیے) اور کیبل کو اچھی طرح باندھ دیں۔
2، 40 ڈگری سینٹی گریڈ سے کم درجہ حرارت کے ساتھ، سنکنرن مادوں اور گیسوں کے بغیر اندرونی کمرے میں اسٹور کریں۔
3، طویل مدتی استعمال سبمرسیبل پمپ کے مورچا کی روک تھام پر توجہ دینا چاہئے.
- امپیلر
- شافٹ آستین
- ربڑ شافٹ آستین
-
سگ ماہی کی انگوٹی
01 گہرے کنویں کا پانی پینا
02 بلند و بالا پانی کی فراہمی
03 پہاڑی پانی کی فراہمی
04 ٹاور پانی
05 زرعی آبپاشی
06 باغ کی آبپاشی
07 دریا کے پانی کی مقدار
08 گھریلو پانی