QJP series special fountain pump is a fountain pump with higher efficiency developed by our factory. The motor core of the pump is made of high quality cold rolled silicon steel, which makes the pump have good magnetic permeability and will not produce heat when starting frequently. The two ends of the motor rotor are equipped with water-lubricated alloy copper sleeves instead of ball bearings, thus avoiding the problem of easy rust of ball bearings and burnout of motor due to lack of oil. 0JP series pump is also equipped with a variety of intelligent functions, such as over-temperature protection, anti-dry burning protection, etc., to ensure the safe operation of the pump. The pump is suitable for fountain decoration in landscape engineering, square, garden and other different occasions, providing users with efficient and reliable pumping solutions.
1, alimentazione: AC trifase 380V (tolleranza + / - 5%), 50HZ (tolleranza + / - 1%).
2, qualità di l'acqua:
(1) water temperature is not higher than 20 °C;
(2) u cuntenutu di impurità solidi (rapportu di massa) ùn hè micca più grande di 0,01%;
(3) valore PH (pH) 6,5-8,5;
(4) u cuntenutu di sulfuru di l'idrogenu ùn hè micca più grande di 1.5mg / L;
(5) u cuntenutu di ioni di cloruri ùn hè micca più grande di 400mg/L.
3, u mutore hè chjusu o struttura bagnata piena d'acqua, prima di usu di a cavità di u mutore sommergibile deve esse piena d'acqua pulita, per impediscenu falsi pienu, è poi stringhje l'iniezione d'acqua, bulloni di liberazione d'aria, altrimenti micca permessu di utilizà
4, a pompa sommergibile deve esse cumplettamente immersa in l'acqua, a prufundità di immersione ùn hè micca più grande di 70m, u fondu di a pompa sommergibile da u fondu di u pozzu ùn hè micca menu di 3m.
5, u flussu di l'acqua di u pozzu deve esse capace di scuntrà a pruduzzione di l'acqua di a pompa sommergibile è u funziunamentu cuntinuu, a pruduzzione di l'acqua di a pompa sommergibile deve esse cuntrullata à 0,7 - 1,2 volte u flussu nominale.
6, u pozzu deve esse drittu, a pompa sommergibile ùn pò esse usata o scaricata, solu usu verticale.
7, a pompa sommergibile deve esse assuciatu cù u cable secondu i bisogni, è u dispusitivu di prutezzione di sovraccarichi esterni.
8, a pompa hè strettamente pruibita senza macchina di prova senza acqua
Mudellu | flussu (m3/h) | Capu (m) |
Velocità di rotazione (cambià / puntu) |
Pompa à acqua (%) | Outlet diamitru (mm) |
Applicabile bè diamitru (mm) |
Classificatu putenza (KW) |
Classificatu tensione (V) |
Classificatu currente (A) |
efficienza di u mutore (%) | power factorcosφ | Unità Dimensione massima radiale (mm) |
Rimarca | |||||||||
150QJ5-100 | 5 | 100 | 2850 | 58 | 40 | 150 | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ5-150 | 5 | 150 | 2850 | 58 | 40 | 150 sopra | 4 | 380 | 10.25 | 75.0 | 0.79 | 143 | ||||||||||
150QJ5-200 | 200 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ5-250 | 250 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ5-300 | 300 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ10-50 | 10 | 50 | 2850 | 63 | 50 | 150sopra | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ10-66 | 66 | 4 | 10.25 | 75.0 | 0.79 | |||||||||||||||||
150QJ10-78 | 78 | 4 | 10.25 | 75.0 | 0.79 | |||||||||||||||||
150QJ10-84 | 84 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ10-91 | 91 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ10-100 | 100 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ10-128 | 128 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ10-150 | 150 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ10-200 | 200 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ10-250 | 250 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ10-300 | 300 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ15-33 | 15 | 33 | 2850 | 63 | 50 | 150sopra | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ15-42 | 42 | 4 | 10.25 | 75.0 | 0.79 | |||||||||||||||||
150QJ15-50 | 50 | 4 | 10.25 | 75.0 | 0.79 | |||||||||||||||||
150QJ15-60 | 60 | 5.5 | 13.74 | 76 | 0.8 | |||||||||||||||||
150QJ15-65 | 65 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ15-72 | 72 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ15-81 | 81 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ15-90 | 90 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ15-98 | 98 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ15-106 | 106 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ15-114 | 114 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ15-130 | 130 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ15-146 | 146 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ15-162 | 162 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ15-180 | 180 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ20-26 | 20 | 26 | 2850 | 64 | 50 | 150sopra | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ20-33 | 33 | 3 | 7.9 | 74.0 | 0.78 | |||||||||||||||||
150QJ20-39 | 20 | 39 | 2850 | 64 | 50 | 150sopra | 4 | 380 | 10.25 | 75.0 | 0.79 | 143 | ||||||||||
150QJ20-52 | 52 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ20-65 | 65 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ20-78 | 78 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ20-91 | 91 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ20-98 | 98 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ20-104 | 104 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ20-111 | 111 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ20-130 | 130 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ20-143 | 143 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ20-156 | 156 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ20-182 | 182 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ25-24 | 25 | 24 | 2850 | 64 | 65 | 150sopra | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ25-32 | 32 | 4 | 10.25 | 75.0 | 0.79 | |||||||||||||||||
150QJ25-40 | 40 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ25-48 | 48 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ25-56 | 56 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ25-64 | 64 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ25-72 | 72 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ25-77 | 77 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ25-84 | 84 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ25-96 | 96 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ25-104 | 104 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ25-110 | 110 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ25-120 | 120 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ25-128 | 128 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ25-136 | 136 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ25-154 | 154 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ32-18 | 32 | 18 | 2850 | 66 | 80 | 150sopra | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ32-24 | 24 | 4 | 10.25 | 75.0 | 0.79 | |||||||||||||||||
150QJ32-30 | 30 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ32-36 | 36 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ32-42 | 32 | 42 | 2850 | 66 | 80 | 150sopra | 7.5 | 380 | 18.5 | 77.0 | 0.8 | 143 | ||||||||||
150QJ32-54 | 54 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ32-66 | 66 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ32-72 | 72 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ32-84 | 84 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ32-90 | 90 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ32-96 | 96 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ32-114 | 114 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ40-16 | 40 | 16 | 2850 | 66 | 80 | 150sopra | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ40-24 | 24 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ40-30 | 30 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ40-40 | 40 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ40-48 | 48 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ40-56 | 56 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ40-64 | 64 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ40-72 | 72 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ40-80 | 80 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ40-96 | 96 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ50-16 | 50 | 16 | 2850 | 65 | 80 | 150sopra | 4 | 380 | 10.25 | 75.0 | 0.79 | 143 | ||||||||||
150QJ50-22 | 22 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ50-28 | 28 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ50-34 | 34 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ50-40 | 40 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ50-46 | 46 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ50-52 | 52 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ50-57 | 57 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ50-74 | 74 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ50-80 | 80 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ63-12 | 63 | 12 | 2850 | 60 | 80 | 150sopra | 4 | 380 | 10.25 | 75.0 | 0.79 | 143 | ||||||||||
150QJ63-18 | 18 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ63-30 | 30 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ63-36 | 36 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ63-42 | 63 | 42 | 2850 | 60 | 80 | 150sopra | 13 | 380 | 30.87 | 79.0 | 0.81 | 143 | ||||||||||
150QJ63-48 | 48 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ63-54 | 54 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ15-220 | 15 | 220 | 2850 | 50 | 150sopra | 18.5 | 380 | 43.12 | 143 | |||||||||||||
150QJ15-260 | 260 | 20 | 49.7 | |||||||||||||||||||
150QJ15-300 | 300 | 25 | 56.5 | |||||||||||||||||||
150QJ20-210 | 20 | 210 | 2850 | 50 | 150sopra | 20 | 380 | 49.7 | 143 | |||||||||||||
150QJ20-240 | 240 | 25 | 56.5 | |||||||||||||||||||
150QJ20-290 | 290 | 30 | 66.6 | |||||||||||||||||||
150QJ25-175 | 25 | 175 | 2850 | 65 | 150sopra | 20 | 49.7 | 143 | ||||||||||||||
150QJ25-200 | 200 | 30 | 66.6 | |||||||||||||||||||
150QJ25-290 | 290 | 37 | 82.1 | |||||||||||||||||||
150QJ32-120 | 32 | 120 | 2850 | 80 | 150sopra | 20 | 380 | 49.7 | 143 | |||||||||||||
150QJ32-132 | 132 | 25 | 56.5 | |||||||||||||||||||
150QJ32-156 | 156 | 30 | 66.6 | |||||||||||||||||||
150QJ32-190 | 190 | 37 | 82.1 | |||||||||||||||||||
150QJ32-240 | 240 | 45 | 96.9 | |||||||||||||||||||
150QJ40-110 | 40 | 110 | 2850 | 80 | 150sopra | 20 | 380 | 49.7 | 143 | |||||||||||||
150QJ40-121 | 121 | 25 | 56.5 | |||||||||||||||||||
150QJ40-143 | 143 | 30 | 66.6 | |||||||||||||||||||
150QJ40-176 | 176 | 37 | 82.1 | |||||||||||||||||||
150QJ40-220 | 220 | 45 | 96.9 | |||||||||||||||||||
150QJ50-100 | 50 | 100 | 2850 | 80 | 150sopra | 20 | 380 | 49.7 | 143 | |||||||||||||
150QJ50-110 | 110 | 25 | 56.5 | |||||||||||||||||||
150QJ50-130 | 130 | 30 | 66.6 | |||||||||||||||||||
150QJ50-160 | 160 | 37 | 82.1 | |||||||||||||||||||
150QJ50-200 | 200 | 45 | 96.9 |
1, pompa sommergibile per a pompa d'acqua pulita, pruibisce u novu pozzu, pumping sedimentu è acqua fangosa,
2, u gradu di tensione di a pompa d'acqua di pozzu 380 / 50HZ, l'usu di altri gradi di tensione di i mutori sommergibili deve esse persunalizatu. U cable sotterraneo deve usà un cable impermeable, deve esse equipatu cù l'equipaggiu di partenza, cum'è a scatula di distribuzione, ùn principia micca prontu deve avè una funzione di prutezzione cumpleta di u mutore cumunimenti utilizata, cum'è a prutezzione di sovraccarichi di cortu circuitu, a prutezzione di fasi, a prutezzione di sottutensione, a prutezzione di terra, a prutezzione di idling. , in casu di cundizioni anormali, u dispusitivu prutezzione deve esse viaghju azzione puntuale.
3, l'installazione è l'usu di a pompa deve esse messa in terra in modu affidabile, pruibisce l'interruttore push and pull quandu e mani è i pedi sò bagnati, deve tagliate l'alimentazione prima di l'installazione è u mantenimentu di a pompa, a pompa usa un locu per stallà " per prevene scossa elettrica" segni evidenti:
4, falà u pozzu o prima di a stallazione, a cavità di u mutore deve esse pienu d'acqua distillata o d'acqua bollente fridda pulita non corrosiva, stringhje u / bullone d'acqua, a pompa nantu à a prova di terra, deve esse à a camera di pompa di gomma di lubrificazione d'acqua. cuscinetti, iniziu istantaneu micca più di un secondu, vede s'ellu hè u listessu cum'è l'istruzzioni di guida. Quandu a pompa hè dritta, fate attenzione à a sicurità, impediscenu a ferita di ribalta.
5, strettamente secondu e disposizioni di l'elevatore di a pompa, a gamma di u flussu d'usu, per prevene a forza di pompamentu di flussu bassu o elevatu, u cuscinettu di spinta è altre parti di l'usura, a sovraccarico di u mutore brusgiatu 6, dopu à a pompa in u pozzu, a misurazione di u mutore à a resistenza d'insulazione di a terra ùn deve esse menu di 100M, dopu à l'iniziu per osservà a tensione è u currente, verificate l'insulazione di u mutore, sia in linea cù i bisogni; a temperatura di u locu di almacenamentu di a pompa si hè menu di u puntu di congelazione, deve esse asciuttu l'acqua di a cavità di u mutore, impedisce a cavità di u mutore di l'acqua di ghiaccio causata da a temperatura bassa.
The pump part is mainly composed of pump shaft, impeller, flow guide housing, rubber bearing, check valve body (optional) and other parts. The motor part is mainly composed of base, pressure regulating diaphragm, thrust bearing, thrust plate, lower guide bearing seat, stator, rotor, upper guide bearing seat, sand discharging ring, water inlet section, lead cable and other parts. The main features of the product include: the motor is a water-filled wet submersible three-phase asynchronous motor, the motor cavity is filled with clear water for cooling the motor and lubricating the bearing, the pressure regulating diaphragm at the bottom of the motor is used to adjust the pressure difference caused by the heating of the motor. In order to prevent the sand in the well water from entering the motor, the upper end of the motor shaft extension is installed with two oil seals, and the sand discharging ring is installed to form a sand prevention structure. In order to avoid the pump shaft jumping when starting, the pump shaft is connected with the motor shaft through a coupling, and the thrust bearing is installed at the bottom of the motor. The lubrication of the motor and the pump bearing is water lubrication, and the stator winding of the motor uses high quality submersible motor wire with high insulation performance. The pump is designed by computer CAD, with simple structure and superior technical performance.

(1) Preparazione prima di a stallazione:
1. Verificate s'ellu a pompa sommergibile risponde à e cundizioni d'utilizazione è u scopu specificate in u manuale.
2. Aduprà un oggettu pisanti cù un diametru uguali à u diametru massimu esterno di a pompa sommergibile, misurà s'ellu u diametru internu di u pozzu pò mette a pompa sommergibile, è misurà s'ellu a prufundità di u pozzu risponde à i requisiti di a stallazione.
3. Verificate se u pozzu hè pulitu è se l'acqua di u pozzu hè turbid. Ùn aduprate mai una pompa elettrica sommergibile per lavà u fangu è l'acqua di sabbia di a pompa welor per evità danni prematuri à a pompa elettrica sommergibile.
4. Verificate s'ellu a pusizione di a pinza di stallazione di u welhead hè adattata è s'ellu pò sustene a qualità di l'unità sana.
5. Verificate se i cumpunenti di a pompa sommergibile sò cumpleti è installati bè secondu u schema di assemblea in u manuale. Rimuove u screnu di filtru è girate l'accoppiamentu per vede s'ellu gira in modu flexible.
6. Unscrew the water screw and fillthe cavità di u mutore cù l'acqua pulita, micca currusiva (nota. assicuratevi di fillà), poi stringhje l'acqua. Dopu à 12 ore d'iniezione d'acqua, a resistenza d'insulazione di u mutore ùn deve esse menu di 150M Q quandu misurata cù una tavola agitante 500V.
7. Cable joint, cut off a 120mm rubber sleeve from one end of the outgoing cable and the matching cable with an electrician's knifethen stagger the length of the three core wires in a stepped shape, peel off a 20mm copper core, scrape of the oxide layer on theoutside of the copper wire with a knife or sand cloth, and insert the two connected wire ends in palirs.After tying the layer tightly with fine copper wire, solder it thoroughly and firmly, and sand of any. burrs on the surface. Then, forthe three joints, use polyvester insulation tape to wrap them in a semi stacked manner for three lavers. Wrap the two ends of thewrapping layer tightywith nyion thread,and then use a semi stacked method to wrap the tape for three layers. Wrap the outellayer with high-pressure insulation tape for three layers. Finally, fold the threestrands together and repeatedly wrap them for fivelayers with high-pressure tape. Each layer must be tightly tied, and the interlayer joints must be tight and fimm to prevent water frompenetrating and damaging the insulation, After wrapping, soak in water at room temperature of 20 ’c for 12 hours, and measurethe insulation resistance with a shaking table, which should not be less than 100M Ω
U schema di u prucessu di cablaggio di u cable attaccatu hè u seguitu:
8. Aduprate un multimetru per verificà se i fili trifasi sò cunnessi è se a resistenza DC hè apprussimatamente equilibrata.
9. Verificate s'ellu u circuitu è a capacità di u transformatore sò sovraccarichi, è dopu cunnette l'interruttore di prutezzione di sopracarga o l'equipaggiu di partenza. Vede a Tabella 2 per mudelli specifichi, è dopu Pour un bucket d'acqua in a pompa d'acqua da l'outlet di a pompa d'acqua per lubricate i cuscinetti di gomma in a pompa, è poi mette a pompa elettrica sommergibile in verticale è stabile. Start (micca più di una seconda) è verificate se a direzzione di a direzzione hè coherente cù u segnu di a direzzione. Se no, scambià ogni dui connettori di u cable trifase. Allora installate u filtru è preparate per falà u pozzu. Sè usatu in occasioni spiciali (cum'è fossi, fossi, fiumi, stagni, stagni, etc.), a pompa elettrica deve esse reliably grounded.
(2) Attrezzatura è arnesi d'installazione:
1. Un paru di catene di elevazione per più di duie tunnellate.
2. Un tripode cù una altezza verticale di micca menu di quattru metri.
3. Dui cordi pendenti (cordi di filu) chì ponu purtà un pesu di più di una tonna (pò suppurtà u pesu di un inseme cumpletu di pompe d'acqua).
4. Installa dui parigli di clamps (splints).
5. Chiavi, martelli, cacciavite, arnesi è strumenti elettrici, etc.
(3) Installazione di pompa elettrica:
1. U schema di stallazione di a pompa elettrica sommergibile hè indicatu in a Figura 2. I dimensioni di l'installazione specifiche sò mostrati in a Table 3 "Lista di dimensioni di l'installazione di a pompa elettrica submersible".
2. Pompe elettriche sommergibili cù una testa menu di 30 metri ponu esse isciutu direttamente in u pozzu utilizendu tubi è corde di filu o altre corde di canapa chì ponu suppurtà u pesu tutale di tutta a macchina, i tubi d'acqua è l'acqua in i tubi.
3. Pompe cù un capu di più di 30 metri utilizanu tubi d'acciaio, è a sequenza di stallazione hè a siguenti:
①Aduprate una pinza per chjappà l'estremità superiore di a parte di a pompa di l'acqua (u mutore è a pompa d'acqua sò stati cunnessi à questu mumentu), alzatelu cù una catena appesa, è legà lentamente in u pozzu finu à mette a pinza nantu à a testa di pozzu è sguassate a pinza. catena appesa.
② Aduprate un altru paru di pinze per chjappà una pipa, sollevala cù una catena pendente à 15 cm di distanza da a flange, è cala lentamente. Trà a flange di pipa è a flange di a pompa. Mettite u pad di gomma in u locu è stringhje a pipa è a pompa uniformemente cù bulloni, noci è rondelle di primavera.
③ Sollevate ligeramente a pompa sommergibile, sguassate a pinza à l'estremità superiore di a pompa d'acqua, attaccate fermamente u cable à a pipa di l'acqua cù una cinta di plastica, è ligate lentamente finu à chì a pinza hè posta à u pozzu.
④Usate u stessu metudu per ligà tutti i tubi d'acqua in u pozzu.
⑤Dopu chì u cable di uscita hè cunnessu à l'interruttore di cuntrollu, hè cunnessu à l'alimentazione trifase.
(4) Cose da nutà durante a stallazione:
1. Sè un fenomenu jamming hè trovu duranti lu prucessu di pumping, girari o tirà u pipa d'acqua à superà u puntu jamming. Se diverse misure ùn anu micca travagliatu, per piacè ùn forza micca a pompa per evità danni à a pompa elettrica sommergibile è u pozzu.
2. Duranti a stallazione, un pad di gomma deve esse postu à a flange di ogni pipa è strettu uniformemente.
3. Quandu a pompa di l'acqua hè calata in u pozzu, deve esse piazzata à mezu à u pipa di u pozzu per impedisce chì a pompa di currerà contru à u muru di u pozzu per un bellu pezzu, facendu chì a pompa vibrerà è u mutore per spazzà è brusgià. .
4. Determinate a prufundità di a pompa di l'acqua à u fondu di u pozzu secondu e cundizioni di sabbia è silt di u pozzu. Ùn enterrate micca a pompa in u fangu. A distanza da a pompa d'acqua à u fondu di u pozzu hè generalmente micca menu di 3 metri (vede a figura 2).
5. A prufundità di l'entrata di l'acqua di a pompa d'acqua ùn deve esse micca menu di 1-1,5 metri da u nivellu di l'acqua dinamica à u node di l'acqua (vede a figura 2). Altrimenti, i cuscinetti di a pompa d'acqua ponu esse facilmente dannati.
6. L'elevatore di a pompa d'acqua ùn pò esse troppu bassu. Altrimenti, una vàlvula di porta deve esse installata nantu à u pipeline di l'acqua di u pozzu per cuntrullà u flussu di a pompa à u puntu di flussu nominale per impedisce chì u mutore sia sovraccaricatu è brusgiatu per via di grandi flussi.
7. Quandu a pompa di l'acqua hè in funziunamentu, a pruduzzione di l'acqua deve esse cuntinuu è ancu, u currente deve esse stabile (sottu e cundizioni di travagliu nominali, in generale micca più di 10% di u currenti nominali), è ùn deve esse micca vibrazione o rumore. Se ci hè qualchì anormalità, a macchina deve esse fermata per scopre a causa è eliminà.
8. Quandu si stallanu, fate attente à a stallazione di u filu di terra di u mutore (vede a Figura 2). Quandu a pipa d'acqua hè una pipa d'acciaio, guidà da a pinza di u pozzu; quandu a pipa d'acqua hè una pipa di plastica, guidala da a marca di terra di a pompa elettrica.
When the submersible pump is installed, recheck the insulation resistance and three-phase connectivity of the switch, and check whether there is any error in the connection between the instrument and the starting equipment. If there is no problem, you can start the test machine. After starting, observe whether the indication reading of each instrument is correct. If the rated voltage and current specified on the nameplate are exceeded, observe whether the pump has any noise or vibration. If everything is normal, you can put into operation. After the first start of the pump for four hours, it should be closed and the thermal insulation resistance of the motor should be quickly tested. Its value should not be less than 0.5 megaohm. After stopping the pump, it should be restarted after a five-minute interval to prevent the water column in the pipeline from completely reversing, resulting in the motor burning due to excessive current. After the pump is put into normal operation, in order to prolong its service life, it is necessary to check regularly whether the supply voltage, working current and insulation resistance are normal. If the following conditions are found, the machine should be shut down immediately to eliminate the fault:
1.the current exceeds 20% under the rated working conditions.
2.the dynamic water level drops to the inlet section, resulting in intermittent drainage.
3.the submersible pump vibrates violently or emits huge noise.
4.the supply voltage is lower than 340 volts.
5.a fuse is blown out.
6.the water pipe is damaged.
7.the thermal insulation resistance of the motor to the ground is less than 0.5 megaohm.
When disassembling the unit:
1.lock the cable, take off the pipeline part, and remove the line protection plate.
2.unscrew the drain bolt, empty all the water in the motor chamber.
3.remove the filter, loosen the screw on the coupling fixed motor shaft.
4.unscrew the bolt connecting the water inlet section and the motor, and separate the pump and the motor (pay attention to the leveling unit when separating to prevent the bending of the pump shaft).
5.the disassembly sequence of the pump is: (see Figure 1) water inlet section, impeller, guide housing, rotor, impeller. Check the valve body. When removing the impeller, use special tools to loosen the conical sleeve fixed on the impeller. In the process of disassembly and assembly, avoid bending the pump shaft and damaging various parts.
6.the disassembly process of the motor is: (see Figure 1) put the motor on the platform, remove the nut, base, shaft head lock nut, thrust plate, key, lower guide rail, support seat, and tie rod bolt from the bottom of the motor in order, and then take out the rotor (be careful not to damage the wiring harness), and finally remove the connecting part and the upper guide rail bearing seat. When assembling the unit: before assembly, rust and dirt on each part should be cleaned and sealant coated on each mating surface and fastener, then assembled in reverse order of disassembly (motor shaft movement after assembly is about 1 mm), after assembly, coupling should be flexible, then put on the filter for testing. Each submersible pump running for one year, or if the running time is less than one year but has been immersed for two years, it must be disassembled and inspected according to Article 5 to replace worn parts.
1, mette l'acqua in a cavità di u mutore (in particulare in l'inguernu per impedisce chì u mutore si congela), è ligà bè u cable.
2, store in an indoor room without corrosive substances and gases, with a temperature below 40 °C.
3, usu à longu andà deve esse attentu à a prevenzione di ruggine di pompe sommergibili.
- Impeller
- A manica di l'arbre
- Manica di l'arbulu di gomma
-
Anellu di sigillatura
01 Ingestione d'acqua di pozzu prufonda
02 Fornitura d'acqua alta
03 supply d'acqua di muntagna
04 torre acqua
05 Irrigazione agricula
06 irrigazione di giardinu
07 acqua di u fiume
08 acqua domestica