QJ series submersible electric pump is a kind of lifting machine directly connected to the submersible motor and pump to work in the water. This series of pumps are vertical, with small footprint, compact structure, simple installation, easy maintenance and repair. It is widely used in agricultural irrigation, municipal engineering, water conservancy, urban water supply and drainage, as well as industrial and mining enterprises, disaster relief drainage and other fields. The flow range is 5-500m3/h, the head is 4-800m, and the power is 3-315KW. This submersible electric pump can efficiently lift and transport water, providing reliable water supply protection for various fields. Its stable performance and solid structure make it an indispensable machine in various water conservancy projects.
This product is a three-phase AC 380V (tolerance ± 5%), 50HZ (tolerance ± 1%) power supply pump, is designed for water requirements of strict occasions. The product is suitable for water temperature not exceeding 20 °C, solid impurities content (mass ratio) is not greater than 0.01%, PH value (pH) is 6.5-8.5, hydrogen sulfide content is not greater than 1.5mg/L, chloride ion content is not greater than 400mg/L water quality environment. The pump adopts closed or water-filled wet structure motor, the inner cavity must be filled with clean water before use to prevent virtual filling, and then tighten the water injection and pressure relief bolts. The product shall be completely immersed in water, the penetration depth shall not exceed 70m, and the distance from the bottom of the well shall not be less than 3m. The water source required by the pump shall be able to meet its output demand and continuous operation, and the output of the pump shall be controlled at 0.7-1.2 times of the rated flow. The well shall be vertical, and the horizontal or inclined use shall be prohibited, and the cable shall be matched according to the requirements and equipped with external overload protection device. It is strictly prohibited to conduct no water test on the electric pump.
Awoṣe | Sisan (m3/h) | Ori (m) |
Iyara yiyipo (ayipada/ojuami) |
Omi (%) | Ijabọ opin (mm) |
Wulo daradara opin (mm) |
Ti won won agbara (KW) |
Ti won won foliteji(V) |
Ti won won lọwọlọwọ (A) |
Iṣiṣẹ mọto (%) | power factorcosφ | Ẹyọ Iwọn Radial ti o pọju (mm) |
Akiyesi | |||||||||
150QJ5-100 | 5 | 100 | 2850 | 58 | 40 | 150 | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ5-150 | 5 | 150 | 2850 | 58 | 40 | 150 loke | 4 | 380 | 10.25 | 75.0 | 0.79 | 143 | ||||||||||
150QJ5-200 | 200 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ5-250 | 250 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ5-300 | 300 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ10-50 | 10 | 50 | 2850 | 63 | 50 | 150loke | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ10-66 | 66 | 4 | 10.25 | 75.0 | 0.79 | |||||||||||||||||
150QJ10-78 | 78 | 4 | 10.25 | 75.0 | 0.79 | |||||||||||||||||
150QJ10-84 | 84 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ10-91 | 91 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ10-100 | 100 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ10-128 | 128 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ10-150 | 150 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ10-200 | 200 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ10-250 | 250 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ10-300 | 300 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ15-33 | 15 | 33 | 2850 | 63 | 50 | 150loke | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ15-42 | 42 | 4 | 10.25 | 75.0 | 0.79 | |||||||||||||||||
150QJ15-50 | 50 | 4 | 10.25 | 75.0 | 0.79 | |||||||||||||||||
150QJ15-60 | 60 | 5.5 | 13.74 | 76 | 0.8 | |||||||||||||||||
150QJ15-65 | 65 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ15-72 | 72 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ15-81 | 81 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ15-90 | 90 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ15-98 | 98 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ15-106 | 106 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ15-114 | 114 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ15-130 | 130 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ15-146 | 146 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ15-162 | 162 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ15-180 | 180 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ20-26 | 20 | 26 | 2850 | 64 | 50 | 150loke | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ20-33 | 33 | 3 | 7.9 | 74.0 | 0.78 | |||||||||||||||||
150QJ20-39 | 20 | 39 | 2850 | 64 | 50 | 150loke | 4 | 380 | 10.25 | 75.0 | 0.79 | 143 | ||||||||||
150QJ20-52 | 52 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ20-65 | 65 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ20-78 | 78 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ20-91 | 91 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ20-98 | 98 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ20-104 | 104 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ20-111 | 111 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ20-130 | 130 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ20-143 | 143 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ20-156 | 156 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ20-182 | 182 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ25-24 | 25 | 24 | 2850 | 64 | 65 | 150loke | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ25-32 | 32 | 4 | 10.25 | 75.0 | 0.79 | |||||||||||||||||
150QJ25-40 | 40 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ25-48 | 48 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ25-56 | 56 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ25-64 | 64 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ25-72 | 72 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ25-77 | 77 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ25-84 | 84 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ25-96 | 96 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ25-104 | 104 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ25-110 | 110 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ25-120 | 120 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ25-128 | 128 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ25-136 | 136 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ25-154 | 154 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ32-18 | 32 | 18 | 2850 | 66 | 80 | 150loke | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ32-24 | 24 | 4 | 10.25 | 75.0 | 0.79 | |||||||||||||||||
150QJ32-30 | 30 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ32-36 | 36 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ32-42 | 32 | 42 | 2850 | 66 | 80 | 150loke | 7.5 | 380 | 18.5 | 77.0 | 0.8 | 143 | ||||||||||
150QJ32-54 | 54 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ32-66 | 66 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ32-72 | 72 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ32-84 | 84 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ32-90 | 90 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ32-96 | 96 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ32-114 | 114 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ40-16 | 40 | 16 | 2850 | 66 | 80 | 150loke | 3 | 380 | 7.9 | 74.0 | 0.78 | 143 | ||||||||||
150QJ40-24 | 24 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ40-30 | 30 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ40-40 | 40 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ40-48 | 48 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ40-56 | 56 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ40-64 | 64 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ40-72 | 72 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ40-80 | 80 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ40-96 | 96 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ50-16 | 50 | 16 | 2850 | 65 | 80 | 150loke | 4 | 380 | 10.25 | 75.0 | 0.79 | 143 | ||||||||||
150QJ50-22 | 22 | 5.5 | 13.74 | 76.0 | 0.8 | |||||||||||||||||
150QJ50-28 | 28 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ50-34 | 34 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ50-40 | 40 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ50-46 | 46 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ50-52 | 52 | 13 | 30.87 | 79.0 | 0.81 | |||||||||||||||||
150QJ50-57 | 57 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ50-74 | 74 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ50-80 | 80 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ63-12 | 63 | 12 | 2850 | 60 | 80 | 150loke | 4 | 380 | 10.25 | 75.0 | 0.79 | 143 | ||||||||||
150QJ63-18 | 18 | 7.5 | 18.5 | 77.0 | 0.8 | |||||||||||||||||
150QJ63-30 | 30 | 9.2 | 22.12 | 78.0 | 0.81 | |||||||||||||||||
150QJ63-36 | 36 | 11 | 26.28 | 78.5 | 0.81 | |||||||||||||||||
150QJ63-42 | 63 | 42 | 2850 | 60 | 80 | 150loke | 13 | 380 | 30.87 | 79.0 | 0.81 | 143 | ||||||||||
150QJ63-48 | 48 | 15 | 35.62 | 79.0 | 0.81 | |||||||||||||||||
150QJ63-54 | 54 | 18.5 | 43.12 | 79.5 | 0.82 | |||||||||||||||||
150QJ15-220 | 15 | 220 | 2850 | 50 | 150loke | 18.5 | 380 | 43.12 | 143 | |||||||||||||
150QJ15-260 | 260 | 20 | 49.7 | |||||||||||||||||||
150QJ15-300 | 300 | 25 | 56.5 | |||||||||||||||||||
150QJ20-210 | 20 | 210 | 2850 | 50 | 150loke | 20 | 380 | 49.7 | 143 | |||||||||||||
150QJ20-240 | 240 | 25 | 56.5 | |||||||||||||||||||
150QJ20-290 | 290 | 30 | 66.6 | |||||||||||||||||||
150QJ25-175 | 25 | 175 | 2850 | 65 | 150loke | 20 | 49.7 | 143 | ||||||||||||||
150QJ25-200 | 200 | 30 | 66.6 | |||||||||||||||||||
150QJ25-290 | 290 | 37 | 82.1 | |||||||||||||||||||
150QJ32-120 | 32 | 120 | 2850 | 80 | 150loke | 20 | 380 | 49.7 | 143 | |||||||||||||
150QJ32-132 | 132 | 25 | 56.5 | |||||||||||||||||||
150QJ32-156 | 156 | 30 | 66.6 | |||||||||||||||||||
150QJ32-190 | 190 | 37 | 82.1 | |||||||||||||||||||
150QJ32-240 | 240 | 45 | 96.9 | |||||||||||||||||||
150QJ40-110 | 40 | 110 | 2850 | 80 | 150loke | 20 | 380 | 49.7 | 143 | |||||||||||||
150QJ40-121 | 121 | 25 | 56.5 | |||||||||||||||||||
150QJ40-143 | 143 | 30 | 66.6 | |||||||||||||||||||
150QJ40-176 | 176 | 37 | 82.1 | |||||||||||||||||||
150QJ40-220 | 220 | 45 | 96.9 | |||||||||||||||||||
150QJ50-100 | 50 | 100 | 2850 | 80 | 150loke | 20 | 380 | 49.7 | 143 | |||||||||||||
150QJ50-110 | 110 | 25 | 56.5 | |||||||||||||||||||
150QJ50-130 | 130 | 30 | 66.6 | |||||||||||||||||||
150QJ50-160 | 160 | 37 | 82.1 | |||||||||||||||||||
150QJ50-200 | 200 | 45 | 96.9 |
1, well submersible pump for clean water pump, prohibit the new well, pumping sediment and muddy water,
2, well water pump voltage grade 380/50HZ, the use of other voltage grades of submersible motors need to be customized.The underground cable must use waterproof cable, must be equipped with starting equipment, such as distribution box, start not ready should have commonly used motor comprehensive protection function, such as short circuit overload protection, phase protection, undervoltage protection, grounding protection, idling protection, in case of abnormal conditions, the protection device should be timely action trip.
3, the installation and use of the pump must be reliably grounded, prohibit the push and pull switch when the hands and feet are wet, the installation and maintenance of the pump must be cut off the power supply, the use of the pump place to set up "to prevent electric shock" obvious sign:
4, down the well or before installation, the motor cavity must be filled with distilled water or non-corrosive clean cold boiling water, tighten the / water bolt, the pump on the ground test run, must be to the pump chamber water lubrication rubber bearings, instant start not more than a second, see whether the steering and steering instructions are the same.When the pump is upright, pay attention to safety, prevent overturning injury.
5, this pump has won wide acclaim for its efficiency and reliability. It is used in strict accordance with the applicable lift and flow range stipulated by the electric pump to avoid excessive wear of thrust bearings and other parts caused by large flow at low lift or excessive pumping force at high lift, resulting in motor overload and burnout. After being put into the well, the insulation resistance to the ground of the electric pump shall be measured and shall not be less than 100MΩ. After starting, the voltage and current shall be observed regularly, and the insulation of the motor winding shall be checked to meet the specified requirements. If the storage temperature is below freezing, the water in the pump shall be dried to avoid damage to the motor due to low temperature freezing in the motor cavity. This electric pump is your reliable choice, which can provide stable and reliable power support for your work.
Structure brief: pump part is mainly composed of pump shaft, impeller, diversion shell, rubber bearing, check valve body (optional parts) and other components.The motor part is mainly composed of base, pressure regulating film, thrust bearing, thrust plate, lower guide bearing seat, stator, rotor, upper guide bearing seat, sand ring, water inlet joint, lead cable and other components.
Awọn ẹya akọkọ ti ọja naa pẹlu:
- 1.The motor is a water-sealed wet submersible three-phase asynchronous motor.The motor cavity is filled with clean water for cooling the motor and lubricating the bearing.The voltage regulating film at the bottom of the motor is used to regulate the temperature rise caused by the motor.The expansion and contraction pressure difference of the body water caused by the change.
- 2. In order to prevent the sand particles in the well water from entering the motor, two oil seals are installed at the upper end of the motor shaft extension, and a sand ring is installed to form a sand prevention structure.
- 3. In order to prevent the pump shaft from jumping at startup, the pump shaft is connected with the motor shaft through a coupling, and a thrust bearing is installed at the lower part of the motor.
- 4. The lubrication of the motor and pump bearing is water lubrication.
- 5. The motor stator winding is made of high-quality submersible motor winding wire, with excellent insulation performance.
- 6. The pump is designed by computer CAD, with simple structure and excellent technical performance.

(1) Igbaradi ṣaaju fifi sori:
1. Ṣayẹwo boya fifa omi inu omi ba pade awọn ipo lilo ati iwọn ti a pato ninu itọnisọna.
2. Lilo obiect ti o wuwo pẹlu iwọn ila opin ti o dọgba si iwọn ila opin ti ita ti o pọju ti fifa fifa, wiwọn boya inneldiameter ti wellbore le ni ibamu si fifa omi ti o wa ni isalẹ, ki o si wiwọn boya ijinle kanga ni ibamu pẹlu awọn ibeere fifi sori ẹrọ.
3. Ṣayẹwo boya ibi kanga jẹ mimọ ati boya omi kanga jẹ turbid. Maṣe lo fifa ina submersible lati fọ ẹrẹ fifa welor ati omi iyanrin lati yago fun ibajẹ ti tọjọ si fifa ina submersible.
4. Ṣayẹwo boya awọn ipo ti awọn welhead fifi sori dimole jẹ dara ati boya o le withstand awọn qualty ti gbogbo kuro
5. Ṣayẹwo boya awọn paati fifa submersible ti pari ati fi sori ẹrọ daradara ni ibamu si apẹrẹ apejọ ti o wa ninu iwe afọwọkọ Yọ iboju àlẹmọ naa ki o si yi asopọ pọ lati rii boya o n yi ni irọrun
6. Unscrew omi dabaru ati ki o fillthe motor iho pẹlu mọ, ti kii ipata omi (akọsilẹ. jẹ daju lati Fil o soke), ki o si Mu awọn waterscrew. Lẹhin awọn wakati 12 ti abẹrẹ omi, idabobo idabobo ti motor ko yẹ ki o kere ju 150M Q nigbati wọn wọn pẹlu tabili gbigbọn 500V.
7. Cable joint, cut off a 120mm rubber sleeve from one end of the outgoing cable and the matching cable with an electrician's knifethen stagger the length of the three core wires in a stepped shape, peel off a 20mm copper core, scrape of the oxide layer on theoutside of the copper wire with a knife or sand cloth, and insert the two connected wire ends in palirs.After tying the layer tightly with fine copper wire, solder it thoroughly and firmly, and sand of any. burrs on the surface. Then, forthe three joints, use polyvester insulation tape to wrap them in a semi stacked manner for three lavers. Wrap the two ends of thewrapping layer tightywith nyion thread,and then use a semi stacked method to wrap the tape for three layers. Wrap the outellayer with high-pressure insulation tape for three layers. Finally, fold the threestrands together and repeatedly wrap them for fivelayers with high-pressure tape. Each layer must be tightly tied, and the interlayer joints must be tight and fimm to prevent water frompenetrating and damaging the insulation, After wrapping, soak in water at room temperature of 20 ’c for 12 hours, and measurethe insulation resistance with a shaking table, which should not be less than 100M Ω
Aworan ilana onirin okun ti a so mọ jẹ bi atẹle:
8. Lo multimeter kan lati ṣayẹwo boya awọn onirin mẹta-alakoso ti wa ni ti sopọ ati boya awọn DC resistance jẹ to iwontunwonsi.
9. Ṣayẹwo boya awọn Circuit ati transformer agbara ti wa ni apọju, ati ki o si so apọju Idaabobo yipada tabi ti o bere ẹrọ. Wo Tabili 2 fun awọn awoṣe kan pato, ati lẹhinna Tú garawa omi kan sinu fifa omi lati inu iṣan omi lati lubricate awọn bearings roba ninu fifa soke, ati lẹhinna gbe fifa ina mọnamọna submersible ni titọ ati iduroṣinṣin.Bẹrẹ (ko si ju iṣẹju kan lọ) ati ki o ṣayẹwo boya itọsọna idari ni ibamu pẹlu ami idari. Ti kii ba ṣe bẹ, paarọ eyikeyi awọn asopọ meji ti okun oni-mẹta. Lẹhinna fi àlẹmọ sori ẹrọ ki o mura lati lọ si isalẹ kanga naa. Ti a ba lo ni awọn iṣẹlẹ pataki (gẹgẹbi awọn koto, awọn koto, awọn odo, awọn adagun omi, awọn adagun omi, ati bẹbẹ lọ), fifa ina mọnamọna gbọdọ wa ni ilẹ ni igbẹkẹle.
(2) Awọn ohun elo fifi sori ẹrọ ati awọn irinṣẹ:
1. Ọkan bata ti awọn ẹwọn gbigbe fun diẹ ẹ sii ju awọn toonu meji lọ.
2. A mẹta pẹlu kan inaro iga ti ko kere ju mẹrin mita.
3. Awọn okun adiye meji (awọn okun waya) ti o le jẹ iwuwo diẹ ẹ sii ju ọkan lọ (le jẹ iwuwo ti pipe pipe ti awọn fifa omi).
4. Fi sori ẹrọ meji orisii clamps (splints).
5. Wrenches, òòlù, screwdrivers, itanna irinṣẹ ati ohun elo, ati be be lo.
(3) Fifi sori ẹrọ fifa ẹrọ itanna:
1. Aworan fifi sori ẹrọ ti fifa ina mọnamọna submersible ti wa ni afihan ni Nọmba 2. Awọn iwọn fifi sori ẹrọ pato ni a fihan ni Table 3 "Akojọ ti Awọn Iwọn fifi sori ẹrọ ti Imudanu Imọlẹ Imọlẹ".
2. Awọn ifasoke ina mọnamọna ti o wa ni isalẹ pẹlu ori ti o kere ju 30 mita ni a le gbe soke taara sinu kanga nipa lilo awọn okun ati awọn okun waya tabi awọn okun hemp miiran ti o le ni kikun iwuwo ti gbogbo ẹrọ, awọn ọpa omi, ati omi ninu awọn paipu.
3. Awọn ifasoke pẹlu ori ti o ju 30 mita lo awọn paipu irin, ati ilana fifi sori ẹrọ jẹ bi atẹle:
① Lo dimole kan lati di opin oke ti apakan fifa omi (moto ati fifa omi ti wa ni asopọ ni akoko yii), gbe e pẹlu ẹwọn ikele, ki o si sorara di e sinu kanga naa titi ti o fi fi dimole si ori kanga ki o si yọkuro ikele pq.
② Lo awọn clamps meji miiran lati di paipu kan, gbe e pẹlu ẹwọn ikele 15 cm kuro ni flange, ki o si lọ silẹ laiyara. Laarin pipe flange ati fifa flangeFi awọn roba pad ni ibi ati Mu paipu ati fifa boṣeyẹ pẹlu boluti, eso ati orisun omi washers.
③ Gbe fifa omi ti o wa ni isalẹ diẹ diẹ, yọ idimu ti o wa ni opin oke ti fifa omi, di okun naa ṣinṣin si paipu omi pẹlu teepu ike kan, ki o si so o lọra titi di igba ti a fi dimu si ibi kanga.
④ Lo ọna kanna lati di gbogbo awọn paipu omi sinu kanga.
⑤ Lẹhin ti okun-jade ti a ti sopọ si iyipada iṣakoso, o ti sopọ si ipese agbara mẹta-alakoso.
(4) Awọn nkan lati ṣe akiyesi lakoko fifi sori ẹrọ:
1. Ti o ba ti a jamming lasan ti wa ni ri nigba ti fifa ilana, tan tabi fa omi paipu lati bori awọn jamming ojuami. Ti ọpọlọpọ awọn igbese ko ba ṣiṣẹ, jọwọ maṣe fi agbara mu fifa soke lati yago fun ibajẹ si fifa ina submersible ati kanga.
2. Lakoko fifi sori ẹrọ, paadi rọba yẹ ki o gbe ni flange ti paipu kọọkan ati ki o ni wiwọ paapaa.
3. Nigbati fifa omi ba ti wa ni isalẹ sinu kanga, o yẹ ki o gbe si arin paipu kanga naa lati ṣe idiwọ fifa soke lati ṣiṣẹ lodi si odi kanga fun igba pipẹ, ti o mu ki fifa soke lati gbọn ati pe ọkọ ayọkẹlẹ lati gba ati sisun. .
4. Ṣe ipinnu ijinle ti fifa omi si isalẹ ti kanga gẹgẹbi iyanrin ti nṣan ati awọn ipo silt ti kanga. Ma ṣe sin fifa soke sinu ẹrẹ. Ijinna lati fifa omi si isalẹ ti kanga ni gbogbogbo ko kere ju awọn mita 3 (wo Nọmba 2).
5. Ijinle titẹsi omi ti fifa omi yẹ ki o jẹ ko kere ju awọn mita 1-1.5 lati ipele omi ti o ni agbara si oju omi ti nwọle (wo Nọmba 2). Bibẹẹkọ, awọn bearings fifa omi le ni irọrun bajẹ.
6. Gbigbe ti fifa omi ko le jẹ kekere ju. Bibẹẹkọ, àtọwọdá ẹnu-ọna nilo lati fi sori ẹrọ lori opo gigun ti omi kanga lati ṣakoso ṣiṣan fifa ni aaye ṣiṣan ti o ni iwọn lati ṣe idiwọ mọto lati ni apọju ati sisun nitori awọn iwọn sisan nla.
7. Nigbati fifa omi ba n ṣiṣẹ, ṣiṣan omi yẹ ki o wa ni ilọsiwaju ati paapaa, lọwọlọwọ yẹ ki o wa ni iduroṣinṣin (labẹ awọn ipo iṣẹ ti a ṣe ayẹwo, ni gbogbo igba ko ju 10% ti iṣiro lọwọlọwọ), ati pe ko yẹ ki o jẹ gbigbọn tabi ariwo. Ti aiṣedeede eyikeyi ba wa, ẹrọ naa yẹ ki o da duro lati wa idi ti o fa ati imukuro rẹ.
8. Nigbati fifi sori, san ifojusi si awọn eto ti awọn motor grounding waya (wo Figure 2). Nigbati paipu omi jẹ paipu irin, darí rẹ lati dimole kanga; nigbati paipu omi jẹ paipu ike kan, darí rẹ lati aami ilẹ ti fifa ina.
- (1)After the submersible pump is installed, check the insulation resistance and three-phase conduction from the switch again, check whether the instrument and the connection of the start equipment are wrong, if there is no problem, the trial machine can be started, and observe whether the indicator readings of the instrument exceed the rated voltage and current specified on the nameplate after the start, and observe whether the pump has noise and vibration phenomenon, and put into operation if everything is normal.
- (2)After the first operation of the pump for four hours, the motor should be shut down to test the thermal insulation resistance quickly, and its value should not be less than 0.5 megaohm.
- (3)After the pump is shut down, it should be started after five minutes to prevent the water column in the pipe from being completely reflowed and causing excessive motor current and burnout.
- (4)After the pump is put into normal operation, in order to prolong its service life, it is necessary to check whether the supply voltage, working current and insulation resistance are normal regularly. If the following conditions are found, the pump should be shut down immediately to troubleshoot.
1 In the rated condition, the current exceeds 20%.
2 Ipele omi ti o ni agbara ṣubu si apakan iwọle omi, ti o nfa omi lainidii.
3 Awọn fifa omi inu omi ni gbigbọn nla tabi ariwo.
4 Foliteji ipese jẹ kekere ju 340 volts.
5 Fiusi kan ti jona.
6 Paipu ipese omi ti bajẹ.
7 The motor's thermal insulation resistance is lower than 0.5 megaohm.
- (5)Unit disassembly:
1 Untie the cable tie, remove the pipeline part, and remove the wire plate.
2 dabaru boluti omi, fi omi sinu iyẹwu motor.
3 yọ àlẹmọ kuro, tú dabaru ti o wa titi lori isopọpọ lati ṣatunṣe ọpa ọkọ.
4 dabaru boluti ti o so apakan omi inu omi pẹlu mọto, ki o si ya fifa soke kuro ninu ọkọ (san akiyesi si aga timutimu nigbati o yapa, lati ṣe idiwọ atunse ti ọpa fifa)
5 awọn disassembly ọkọọkan ti awọn fifa ni: (wo nọmba 1) omi agbawọle apakan, impeller, diversion ikarahun, impeller ...... ṣayẹwo àtọwọdá ara, nigbati o ba yọ awọn impeller, lo pataki irinṣẹ lati loosen awọn conical apo ti awọn ti o wa titi impeller akọkọ, ki o si yago fun atunse ati sọgbẹni awọn ọpa fifa ninu awọn ilana ti disassembly.
6 ilana disassembly ti awọn motor ni: (wo nọmba 1) gbe awọn motor lori Syeed, ki o si yọ awọn eso, mimọ, ọpa ori tilekun nut, titari awo, bọtini, isalẹ guide ti nso ijoko ati ki o ė ori boluti lati isalẹ ti. awọn motor ni Tan, ati ki o si ya jade awọn ẹrọ iyipo (san ifojusi ko si ba awọn waya package) ati nipari yọ awọn asopọ apakan ati oke guide ti nso ijoko.
7 kuro ijọ: ṣaaju ki o to ijọ, awọn ipata ati dọti ti awọn ẹya yẹ ki o wa ni ti mọtoto, ati awọn ibarasun dada ati fasteners ti a bo pẹlu sealant, ati ki o si jọ ni idakeji ibere ti disassembly (awọn motor ọpa rare si oke ati isalẹ lẹhin ijọ fun nipa ọkan. milimita), lẹhin apejọ, asopọ yẹ ki o rọ, ati lẹhinna ẹrọ idanwo iboju àlẹmọ. Awọn ifasoke submersible ni ao mu jade lati inu kanga fun fifọ ati itọju ni ibamu si Abala 5 lẹhin ọdun kan ti iṣẹ, tabi kere si ọdun kan ti iṣẹ ṣugbọn ọdun meji ti akoko omiwẹ, ati awọn ẹya ti o wọ ni yoo rọpo.
In order to ensure long-term use of your submersible pump, we strongly recommend that you drain the water in all motor cavities especially in winter to prevent the motor from freezing; at the same time, roll up the cable and tie it well. Store the equipment in a room without corrosive substances and gases, with the temperature below 40 °C. In addition, if you do not use the submersible pump for a long time, be sure to pay attention to rust prevention measures. These simple steps will help you maintain the performance of the equipment and extend its service life.
- Impeller
- Ọwọ ọpa
- Roba ọpa apo
-
Iwọn edidi
01 Gbigbe omi kanga ti o jinlẹ
02 Giga-jinde omi ipese
03 oke omi ipese
04 omi ẹṣọ
05 Ogbin irigeson
06 irigeson ọgba
07 odo omi gbigbemi
08 omi inu ile