125QJP Pwmp Tanddwr Peep Well

Ymgymryd â phrosesu OEM! Yn ôl gofynion defnyddwyr, dylunio a gweithgynhyrchu gwahanol fathau o ofynion arbennig modur a phwmp tanddwr ansafonol. Y safonau gweithredu cynnyrch: GB/T2816-2014 "pwmp tanddwr yn dda", GB/T2818-2014 "modur asyncronig tanddwr yn dda". WhatsApp: 17855846335
PDF DOWNLOAD
Manylion
Tagiau
 
Trosolwg Cynnyrch

QJP series fountain pump is a fountain pump with higher efficiency developed and researched by our factory. The pump motor core adopts high quality cold rolled silicon steel, which makes the pump have good magnetic conductivity and frequent start without heating.

The motor rotor ends use water as lubricant alloy copper sleeve instead of ball bearings, avoiding the problem of easy rust, rust and lack of oil wear and tear of the motor.

 

 
Amodau Defnyddio

1, cyflenwad pŵer: AC tri cham 380V (goddefgarwch + / - 5%), 50HZ (goddefgarwch + / - 1%).

2, ansawdd dŵr:

(1) water temperature is not higher than 20 °C;

(2) nid yw cynnwys amhureddau solet (cymhareb màs) yn fwy na 0.01%;

(3) PH gwerth (pH) 6.5-8.5;

(4) nid yw cynnwys hydrogen sylffid yn fwy na 1.5mg/L;

(5) nid yw cynnwys ïon clorid yn fwy na 400mg / L.

3, mae'r modur ar gau neu strwythur gwlyb llawn dŵr, cyn ei ddefnyddio rhaid i'r ceudod modur tanddwr fod yn llawn dŵr glân, i atal ffug llawn, ac yna tynhau'r chwistrelliad dŵr, bolltau rhyddhau aer, fel arall ni chaniateir defnyddio

4, rhaid i bwmp tanddwr gael ei foddi'n llwyr yn y dŵr, nid yw'r dyfnder deifio yn fwy na 70m, nid yw gwaelod y pwmp tanddwr o waelod y ffynnon yn llai na 3m.

5, dylai llif dŵr y ffynnon allu bodloni'r allbwn dŵr pwmp tanddwr a gweithrediad parhaus, dylid rheoli allbwn dŵr y pwmp tanddwr ar 0.7 - 1.2 gwaith y llif graddedig.

6, dylai'r ffynnon fod yn syth, ni all y pwmp tanddwr gael ei ddefnyddio na'i ddympio, dim ond defnydd fertigol.

7, rhaid i'r pwmp tanddwr gael ei gydweddu â'r cebl yn unol â'r gofynion, a'r ddyfais amddiffyn gorlwytho allanol.

8, mae'r pwmp wedi'i wahardd yn llym heb beiriant prawf no-load dŵr

 

 
Ystyr Model

125QJP Peep Well Submersible Pump

 
Cyfeirnod Model Rhannol
Model Llif (m3/h) Pen
(m)

Cyflymder cylchdroi

(newid/pwynt)

Pwmp dŵr(%) Allfa
diamedr
(mm)
Yn berthnasol yn dda
diamedr (mm) 
Wedi'i raddio
pŵer (KW)
Wedi'i raddio
foltedd(V)
Wedi'i raddio
cerrynt (A)
 Effeithlonrwydd modur (%)  power factorcosφ  Uned
Maint mwyaf rheiddiol (mm)
Sylw
125QJ5-34 5 34 2850 53 40  125uchod 1.5 380 4.23 70.0 0.77 118  
125QJ5-51 51 2.2 6.03 72.0 0.77  
125QJ5-68 68 3 8.01 73.0 0.78  
125QJ5-85 85 4 10.53 74.0 0.78  
125QJ5-102 102 5.5 14.1 75.0 0.79  
125QJ5-119 119 5.5 14.1 75.0 0.79  
125QJ10-24 10 24 2850 60 50  125uchod 1.5 380 4.23 70.0 0.77 118  
125QJ10-32 32 2.2 6.03 72.0 0.77  
125QJ10-48 48 3 8.01 73.0 0.78  
125QJ10-56 56 4 10.53 74.0 0.78  
125QJ10-72 72 5.5 14.1 75.0 0.79  
125QJ10-80 80 5.5 14.1 75.0 0.79  
125QJ10-104 104 7.5 19.0 76.0 0.79  
125QJ10-120 10 120 2850 60 50  125uchod 7.5 380 19.0 76.0 0.79 118  
125QJ10-136 136 9.2 22.7 77.0 0.8  
125QJ15-36 15 36 2850 63 50  125uchod 2.2 380 6.03 72.0 0.77 118  
125QJ15-39 39 3 8.01 73.0 0.78  
125QJ15-46 46 4 10.53 74.0 0.78  
125QJ15-52 52 4 10.53 74.0 0.78  
125QJ15-59 59 5.5 14.1 75.0 0.79  
125QJ15-65 65 5.5 14.1 75.0 0.79  
125QJ15-78 78 7.5 19.0 76.0 0.79  
125QJ15-91 91 7.5 19.0 76.0 0.79  
125QJ15-104 104 9.2 22.7 77.0 0.8  
125QJ20-16 20 16 2850 64 50  125uchod 2.2 380 6.03 72.0 0.77 118  
125QJ20-24 24 3 8.01 73.0 0.78  
125QJ20-32 32 4 10.53 74.0 0.78  
125QJ20-40 40 4 10.53 74.0 0.78  
125QJ20-48 48 5.5 14.1 75.0 0.79  
125QJ20-56 56 5.5 14.1 75.0 0.79  
125QJ20-64 64 7.5 19.0 76.0 0.79  
125QJ20-72 72 7.5 19.0 76.0 0.79  
125QJ20-80 80 9.2 22.7 77.0 0.8  
125QJ25-12 25 12 2850 64 65  125uchod 2.2 380 6.03 72.0 0.77 118  
125QJ25-18 18 3 8.01 73.0 0.78  
125QJ25-24 24 4 10.53 74.0 0.78  
125QJ25-30 30 4 10.53 74.0 0.78  
125QJ25-36 36 5.5 14.1 75.0 0.79  
125QJ25-48 48 7.5 19.0 76.0 0.79  
125QJ25-60 60 9.2 22.7 77.0 0.8  
125QJ32-24 32 24 2850 64 80  125uchod 4 380 10.53 74.0 0.78 118  
125QJ32-30 30 5.5 14.1 75.0 0.79  
125QJ32-42 42 7.5 19.0 76.0 0.79  
125QJ32-54 54 9.2 22.7 77.0 0.8  
125QJ5-240 5 240 2850   40  125uchod 11 380 26.28     118  
125QJ5-280 280 13 30.87      
125QJ5-320 320 15 35.62      
125QJ10-180 10 180 2850   50  125uchod 11 380 26.28     118  
125QJ10-210 210 13 30.87      
125QJ10-240 240 15 35.62      
125QJ15-120 15 120 2850   50  125uchod 11 380 26.28     118  
125QJ15-142 142 13 30.87      
125QJ15-162 162 15 35.62      
125QJ20-100 20 100 2850   50  125uchod 11 380 26.28     118  
125QJ20-120 120 13 30.87      
125QJ20-136 136 15 35.62      
125QJ25-82 25 82 2850   65  125uchod 11 380 26.28     118  
125QJ25-97 97 13 30.87      
125QJ25-110 110 15 35.62      
125QJ32-68 32 68 2850   80  125uchod 11 380 26.28     118  
125QJ32-80 80 13 30.87      
125QJ32-92 92 15 35.62      
125QJ40-46 40 46 2850   80  125uchod 11 380 26.28     118  
125QJ40-54 54 13 30.87      
125QJ40-62 62 15 35.62      

 

 
Rhagofalon Diogelwch

1, well submersible pump for clean water pump, prohibit the new well, pumping sediment and muddy water,

2, well water pump voltage grade of 380/50HZ, the use of other voltage grades of submersible motors need to be customized. The underground cable must use waterproof cable, must be equipped with starting equipment, such as distribution box, start not ready should have commonly used motor comprehensive protection function, such as short circuit overload protection, phase protection, undervoltage protection, grounding protection, idling protection, in case of abnormal conditions, the protection device should be timely action trip.

3, the installation and use of the pump must be reliably grounded, prohibit the push and pull switch when the hands and feet are wet, the installation and maintenance of the pump must be cut off the power supply, the use of the pump place to set up "to prevent electric shock" obvious signs:

4, down the well or before installation, the motor cavity must be filled with distilled water or non-corrosive clean cold boiling water, tighten the / water bolt, the pump on the ground test run, must be to the pump chamber water lubrication rubber bearings, instant start not more than a second, see whether the steering is the same as the steering instructions. When the pump is upright, pay attention to safety, prevent overturning injury.

5, yn llym yn unol â darpariaethau'r lifft pwmp, ystod llif y defnydd, i atal llif isel neu rym pwmpio lifft uchel, y dwyn byrdwn a rhannau eraill o'r gwisgo, y gorlwytho modur llosgi

6, after the pump down the well, the measurement of the motor to the ground insulation resistance should not be less than 100M, after the start to observe the voltage and current, check the motor winding insulation, whether in line with the requirements; pump storage location temperature if less than freezing point, should be dry the motor cavity water, prevent the motor cavity water ice damage caused by low temperature.

 

 
Cyflwyniad i Strwythur

Cyflwyniad byr o'r strwythur: mae rhan pwmp yn cynnwys siafft pwmp, impeller, cragen dargyfeirio, dwyn rwber, corff falf gwirio (rhannau dewisol) a chydrannau eraill yn bennaf. Mae rhan modur yn bennaf yn cynnwys sylfaen, ffilm rheoli pwysau, dwyn byrdwn, plât byrdwn, sedd dwyn canllaw is, stator, rotor, sedd dwyn canllaw uchaf, cylch tywod, adran fewnfa ddŵr, cebl a chydrannau eraill.


Mae prif nodweddion y cynnyrch yn cynnwys:

 1, Mae'r modur yn fodur asyncronig tri cham tanddwr gwlyb llawn dŵr, mae'r ceudod modur yn llawn dŵr glân, a ddefnyddir i oeri'r modur ac iro'r dwyn, defnyddir y ffilm sy'n rheoleiddio pwysau ar waelod y modur i addasu gwahaniaeth pwysedd ehangu a chrebachu y dŵr y tu mewn i'r corff a achosir gan newid cynnydd tymheredd y modur.

 2, Er mwyn atal y tywod yn y dŵr ffynnon rhag mynd i mewn i'r modur, mae dwy sêl olew ar ben uchaf y siafft modur, ac mae cylch tywod wedi'i osod i ffurfio strwythur atal tywod.

 3, Er mwyn atal y siafft pwmp rhag rhedeg i fyny wrth gychwyn, mae'r siafft pwmp a'r siafft modur wedi'u cysylltu gan gyplu, a gosodir dwyn byrdwn uchaf ar ran isaf y modur.

 4, Mae iro'r modur a'r dwyn pwmp yn iro dŵr.

 5, Mae'r weindio stator modur wedi'i wneud o wifren dirwyn modur tanddwr o ansawdd uchel, gyda pherfformiad inswleiddio uchel.

 6, Mae'r pwmp wedi'i ddylunio gan gyfrifiadur CAD, gyda strwythur syml a pherfformiad technegol da.

125QJP Peep Well Submersible Pump
 
Gosod

(1) Paratoi cyn gosod:
1. Gwiriwch a yw'r pwmp tanddwr yn bodloni'r amodau defnydd a'r cwmpas a nodir yn y llawlyfr.
2. Gan ddefnyddio gwrthrych trwm gyda diamedr sy'n hafal i diamedr allanol uchaf y pwmp tanddwr, mesurwch a all diamedr mewnol y ffynnon ffitio'r pwmp tanddwr, a mesur a yw dyfnder y ffynnon yn bodloni'r gofynion gosod.
3. Gwiriwch a yw tyllu'r ffynnon yn lân ac a yw dŵr y ffynnon yn gymylog. Peidiwch byth â defnyddio pwmp trydan tanddwr i olchi mwd y pwmp welor a dŵr tywod er mwyn osgoi niwed cynamserol i'r pwmp trydan tanddwr.
4. Gwiriwch a yw lleoliad y clamp gosod welhead yn addas ac a all wrthsefyll ansawdd yr uned gyfan
5. Gwiriwch a yw'r cydrannau pwmp tanddwr wedi'u cwblhau a'u gosod yn iawn yn ôl y diagram cydosod yn y llawlyfr Tynnwch y sgrin hidlo a chylchdroi'r cyplydd i weld a yw'n cylchdroi yn hyblyg
6. Dadsgriwiwch y sgriw dŵr a llenwi'r ceudod modur â dŵr glân nad yw'n cyrydol (noder. gwnewch yn siŵr ei ffiltro), yna tynhau'r sgriw dŵr. Ar ôl 12 awr o chwistrelliad dŵr, ni ddylai ymwrthedd inswleiddio'r modur fod yn llai na 150M Q wrth ei fesur gyda bwrdd ysgwyd 500V.
7. Cable joint, cut off a 120mm rubber sleeve from one end of the outgoing cable and the matching cable with an electrician's knifethen stagger the length of the three core wires in a stepped shape, peel off a 20mm copper core, scrape of the oxide layer on theoutside of the copper wire with a knife or sand cloth, and insert the two connected wire ends in palirs.After tying the layer tightly with fine copper wire, solder it thoroughly and firmly, and sand of any. burrs on the surface. Then, forthe three joints, use polyvester insulation tape to wrap them in a semi stacked manner for three lavers. Wrap the two ends of thewrapping layer tightywith nyion thread,and then use a semi stacked method to wrap the tape for three layers. Wrap the outellayer with high-pressure insulation tape for three layers. Finally, fold the threestrands together and repeatedly wrap them for fivelayers with high-pressure tape. Each layer must be tightly tied, and the interlayer joints must be tight and fimm to prevent water frompenetrating and damaging the insulation, After wrapping, soak in water at room temperature of 20 ’c for 12 hours, and measurethe insulation resistance with a shaking table, which should not be less than 100M Ω

 

Mae'r diagram proses gwifrau cebl ynghlwm fel a ganlyn:

125QJP Peep Well Submersible Pump

 

8. Defnyddiwch amlfesurydd i wirio a yw'r gwifrau tri cham wedi'u cysylltu ac a yw'r gwrthiant DC yn gyfartal yn fras.
9. Gwiriwch a yw'r cylched a chynhwysedd y trawsnewidydd yn cael eu gorlwytho, ac yna cysylltu'r switsh amddiffyn gorlwytho neu'r offer cychwyn. Gweler Tabl 2 am fodelau penodol, ac yna Arllwyswch bwced o ddŵr i'r pwmp dŵr o'r allfa pwmp dŵr i iro'r Bearings rwber yn y pwmp, ac yna gosodwch y pwmp trydan tanddwr yn unionsyth ac yn gyson.Start (dim mwy nag un eiliad) a gwirio a yw'r cyfeiriad llywio yn gyson â'r arwydd llywio. Os na, cyfnewidiwch unrhyw ddau gysylltydd o'r cebl tri cham. Yna gosodwch yr hidlydd a pharatowch i fynd i lawr y ffynnon. Os caiff ei ddefnyddio mewn achlysuron arbennig (fel ffosydd, ffosydd, afonydd, pyllau, pyllau, ac ati), rhaid i'r pwmp trydan gael ei seilio'n ddibynadwy.

 

(2) Offer ac offer gosod:
1. Un pâr o gadwyni codi am fwy na dwy dunnell.
2. Trybedd gydag uchder fertigol o ddim llai na phedwar metr.
3. Dau raff hongian (rhaffau gwifren) sy'n gallu dwyn pwysau o fwy nag un tunnell (gall ddwyn pwysau set gyflawn o bympiau dŵr).
4. Gosod dau bâr o clampiau (splints).
5. Wrenches, morthwylion, sgriwdreifers, offer trydanol ac offerynnau, ac ati.

 

(3) Gosod pwmp trydan:
1. Dangosir diagram gosod y pwmp trydan tanddwr yn Ffigur 2. Dangosir y dimensiynau gosod penodol yn Nhabl 3 "Rhestr o Dimensiynau Gosod y Pwmp Trydan Tanddwr".

 

2. Gellir codi pympiau trydan tanddwr â phen llai na 30 metr yn uniongyrchol i'r ffynnon gan ddefnyddio pibellau a rhaffau gwifren neu rhaffau cywarch eraill a all ddwyn pwysau llawn y peiriant cyfan, pibellau dŵr, a dŵr yn y pibellau.

 

3. Mae pympiau â phen o fwy na 30 metr yn defnyddio pibellau dur, ac mae'r dilyniant gosod fel a ganlyn:
①Defnyddiwch clamp i glampio pen uchaf rhan y pwmp dŵr (mae'r modur a'r pwmp dŵr wedi'u cysylltu ar hyn o bryd), codwch ef â chadwyn hongian, a'i glymu'n araf i mewn i'r ffynnon nes i chi roi'r clamp ar ben y ffynnon a thynnu'r cadwyn hongian.
② Defnyddiwch bâr arall o clampiau i glampio pibell, ei godi â chadwyn hongian 15 cm i ffwrdd o'r fflans, a'i ostwng yn araf. Rhwng fflans pibell a fflans pwmp Rhowch y pad rwber yn ei le a thynhau'r bibell a'r pwmp yn gyfartal â bolltau, cnau a wasieri gwanwyn.
③ Codwch y pwmp tanddwr ychydig, tynnwch y clamp ar ben uchaf y pwmp dŵr, clymwch y cebl yn gadarn i'r bibell ddŵr gyda thâp plastig, a'i glymu'n araf nes bod y clamp wedi'i osod ar ben y ffynnon.
④ Defnyddiwch yr un dull i glymu'r holl bibellau dŵr i'r ffynnon.
⑤ Ar ôl i'r cebl plwm-allan gael ei gysylltu â'r switsh rheoli, mae'n gysylltiedig â'r cyflenwad pŵer tri cham.


(4) Pethau i'w nodi yn ystod y gosodiad:
1. Os canfyddir ffenomen jamio yn ystod y broses bwmpio, trowch neu tynnwch y bibell ddŵr i oresgyn y pwynt jamio. Os nad yw mesurau amrywiol yn gweithio o hyd, peidiwch â gorfodi'r pwmp i lawr er mwyn osgoi difrod i'r pwmp trydan tanddwr a'r ffynnon.
2. Yn ystod y gosodiad, dylid gosod pad rwber ar fflans pob pibell a'i dynhau'n gyfartal.
3. Pan fydd y pwmp dŵr yn cael ei ostwng i'r ffynnon, dylid ei osod yng nghanol pibell y ffynnon i atal y pwmp rhag rhedeg yn erbyn wal y ffynnon am amser hir, gan achosi'r pwmp i ddirgrynu a'r modur i ysgubo a llosgi .
4. Darganfyddwch ddyfnder y pwmp dŵr i waelod y ffynnon yn ôl amodau tywod a silt y ffynnon sy'n llifo. Peidiwch â chladdu'r pwmp yn y mwd. Yn gyffredinol, nid yw'r pellter o'r pwmp dŵr i waelod y ffynnon yn llai na 3 metr (gweler Ffigur 2).
5. Ni ddylai dyfnder mynediad dŵr y pwmp dŵr fod yn llai na 1-1.5 metr o lefel y dŵr deinamig i'r nod mewnfa dŵr (gweler Ffigur 2). Fel arall, gall y Bearings pwmp dŵr gael eu niweidio'n hawdd.
6. Ni all lifft y pwmp dŵr fod yn rhy isel. Fel arall, mae angen gosod falf giât ar bibell ddŵr y ffynnon i reoli llif y pwmp ar y pwynt llif graddedig i atal y modur rhag cael ei orlwytho a'i losgi oherwydd cyfraddau llif mawr.
7. Pan fydd y pwmp dŵr yn rhedeg, dylai'r allbwn dŵr fod yn barhaus a hyd yn oed, dylai'r presennol fod yn sefydlog (o dan amodau gwaith graddedig, yn gyffredinol dim mwy na 10% o'r cerrynt graddedig), ac ni ddylai fod unrhyw ddirgryniad na sŵn. Os oes unrhyw annormaledd, dylid stopio'r peiriant i ddarganfod yr achos a'i ddileu.
8. Wrth osod, rhowch sylw i osodiad y wifren sylfaen modur (gweler Ffigur 2). Pan fydd y bibell ddŵr yn bibell ddur, ei harwain o'r clamp pen ffynnon; pan fydd y bibell ddŵr yn bibell blastig, ei arwain o farc sylfaen y pwmp trydan.

 

 
Cynnal a Chadw
  • 1.Ar ôl gosod y pwmp tanddwr, gwiriwch y gwrthiant inswleiddio a dargludiad tri cham o'r switsh eto, gwiriwch a yw'r offeryn a chysylltiad yr offer cychwyn yn anghywir, os nad oes problem, gellir cychwyn y peiriant prawf, ac arsylwi a yw darlleniadau dangosydd yr offeryn yn fwy na'r foltedd graddedig a'r cerrynt a nodir ar y plât enw ar ôl y cychwyn, ac arsylwi a oes gan y pwmp ffenomen sŵn a dirgryniad, a'i roi ar waith os yw popeth yn normal.
  • 2.Ar ôl gweithrediad cyntaf y pwmp am bedair awr, dylai'r modur gael ei gau i lawr i brofi'r ymwrthedd inswleiddio thermol yn gyflym, ac ni ddylai ei werth fod yn llai na 0.5 megaohm.
  • 3.Ar ôl i'r pwmp gael ei gau i lawr, dylid ei gychwyn ar ôl pum munud i atal y golofn ddŵr yn y bibell rhag cael ei hail-lifo'n llwyr ac achosi cerrynt modur gormodol a llosg.
  • 4.Ar ôl i'r pwmp gael ei roi ar waith yn normal, er mwyn ymestyn ei fywyd gwasanaeth, mae angen gwirio a yw'r foltedd cyflenwad, cerrynt gweithio a gwrthiant inswleiddio yn normal yn rheolaidd. Os canfyddir yr amodau canlynol, dylid cau'r pwmp ar unwaith i ddatrys problemau.
  •  
  • - Yn y cyflwr graddedig, mae'r presennol yn fwy na 20%.
  • - Mae lefel y dŵr deinamig yn disgyn i'r adran fewnfa dŵr, gan achosi dŵr ysbeidiol.
  • - Mae gan y pwmp tanddwr dirgryniad neu sŵn difrifol.
  • - Mae foltedd y cyflenwad yn is na 340 folt.
  • - Mae ffiws yn cael ei losgi allan.
  • - Mae'r bibell cyflenwad dŵr wedi'i ddifrodi.
  • - Mae ymwrthedd inswleiddio thermol y modur yn is na 0.5 megaohm.
  •  
  • Unit disassembly:
  • (1)Untie the cable tie, remove the pipeline part, and remove the wire plate.
  • (2)screw down the water bolt, put the water in the motor chamber.
  • (3)remove the filter, loose the fixed screw on the coupling to fix the motor shaft.
  • (4)screw down the bolt connecting the water inlet section with the motor, and separate the pump from the motor (pay attention to the unit cushion when separating, to prevent the bending of the pump shaft)
  • (5)the disassembly sequence of the pump is: (see figure 1) water inlet section, impeller, diversion shell, impeller...... check valve body, when removing the impeller, use special tools to loosen the conical sleeve of the fixed impeller first, and avoid bending and bruising the pump shaft in the process of disassembly.
  • (6)the disassembly process of the motor is: (see figure 1) place the motor on the platform, and remove the nuts, base, shaft head locking nut, thrust plate, key, lower guide bearing seat and double head bolt from the bottom of the motor in turn, and then take out the rotor (pay attention not to damage the wire package) and finally remove the connecting section and upper guide bearing seat.
  • (7)unit assembly: before assembly, the rust and dirt of the parts should be cleaned, and the mating surface and fasteners coated with sealant, and then assembled in the opposite order of disassembly (the motor shaft moves up and down after assembly for about one millimeter), after assembly, the coupling should be flexible, and then the filter screen test machine. Submersible pumps shall be taken out of the well for dismantling and maintenance according to Article 5 after a year of operation, or less than a year of operation but two years of diving time, and the worn parts shall be replaced.
  •  
 
Storio a Dalfa

 1, rhowch y dŵr allan yn y ceudod modur (yn enwedig yn y gaeaf i atal y modur rhag rhewi), a chlymwch y cebl yn dda.

 2, store in an indoor room without corrosive substances and gases, with a temperature below 40 °C.

 3, dylai defnydd hirdymor roi sylw i atal rhwd pympiau tanddwr.

 

 
Gwisgo Rhannau
  • Impeller
  • Llawes siafft
  • Llawes siafft rwber
  • Modrwy selio

 
Senarios Cais

01 Cymeriant dŵr ffynnon dwfn

02 Cyflenwad dŵr uchel

03 cyflenwad dŵr mynydd 

04 twr dwr

05 Dyfrhau amaethyddol

06 dyfrhau gardd

07 cymeriant dŵr afon

08 dŵr domestig

 

Os oes gennych ddiddordeb yn ein cynnyrch, gallwch ddewis gadael eich gwybodaeth yma, a byddwn yn cysylltu â chi yn fuan.


Ysgrifennwch eich neges yma a'i hanfon atom

Os oes gennych ddiddordeb yn ein cynnyrch, gallwch ddewis gadael eich gwybodaeth yma, a byddwn yn cysylltu â chi yn fuan.


cyWelsh