125QJP Peep Bene Submersible Pump

OEM processus suscipe! Secundum usus usorum, consilium et fabricare varias species speciales requisita submersible motor et sentina non vexillum. Exsequendi signa: GB/T2816-2014 "Sentinam bene submersibilem", GB/T2818-2014 "Motorem asynchronum bene submersibile". Whatsapp: 17855846335
PDF DOWNLOAD
Details
Tags
 
Product Overview

QJP series fountain pump is a fountain pump with higher efficiency developed and researched by our factory. The pump motor core adopts high quality cold rolled silicon steel, which makes the pump have good magnetic conductivity and frequent start without heating.

The motor rotor ends use water as lubricant alloy copper sleeve instead of ball bearings, avoiding the problem of easy rust, rust and lack of oil wear and tear of the motor.

 

 
Conditiones usus

1, potestas supple: three-phase AC 380V (tolerantia + / - 5%), 50HZ (tolerantia + / - 1%).

2, aquae qualitate;

(1) Aqua temperatura non est altior quam XX °C;

(2) immunditia solida contenta (ratio massae) non maior est quam 0.01%;

(3) PH valorem (pH) 6.5-8.5;

(4) hydrogenii sulfidelis contentum 1.5mg/L majus non est;

(5) Ion contentum chloridum maius 400mg/L non est.

III, motor clauditur vel aqua repleta humida structura, antequam uti cavitas submersibilis motoris plena sit aqua munda, ne falsa plena sit, et deinde aqua infusione obstringere, aere emittere fulmina, secus uti non licet.

IV, sentinam submersibilem penitus demergi debet in aqua, urinarum profunditas non est maior quam 70m, imo sentina submersibilis ab imo putei non minus quam 3m.

V, puteus aquae fluxus in sentinam aquae submersibilis output et operationem continuam occurrere possit, sentinae aquae output submersibilis coerceri debet ad 0.7 - 1.2 temporibus fluxus aestimatus.

VI, puteus rectum esse, sentinam submersible vel rasurae adhiberi non potest, tantum verticali usu.

VII, sentinam submersibilem aequare oportet cum fune secundum exigentias, et externam fabricam tutelae cultro.

VIII, sentinam sine aqua nullo onere test machinari stricte prohibetur

 

 
Model Meaning

 
Partialis Model Reference
Model Flow (m3/h) Caput
(m)

Rotatingspeed

(Mutatio / punctum)

Aqua sentinam(%) Outlet
diametri
(mm)
Lorem bene
diametri (mm) 
Ratum
potestas(KW)
Ratum
voltage(V)
Ratum
current (A *
 Motorefficiency (%)  potentia factorcosφ  Unitas
Aculeis Maximus amplitudo (mm)
Animadverte
125QJ5-34 5 34 2850 53 40  125supra 1.5 380 4.23 70.0 0.77 118  
125QJ5-51 51 2.2 6.03 72.0 0.77  
125QJ5-68 68 3 8.01 73.0 0.78  
125QJ5-85 85 4 10.53 74.0 0.78  
125QJ5-102 102 5.5 14.1 75.0 0.79  
125QJ5-119 119 5.5 14.1 75.0 0.79  
125QJ10-24 10 24 2850 60 50  125supra 1.5 380 4.23 70.0 0.77 118  
125QJ10-32 32 2.2 6.03 72.0 0.77  
125QJ10-48 48 3 8.01 73.0 0.78  
125QJ10-56 56 4 10.53 74.0 0.78  
125QJ10-72 72 5.5 14.1 75.0 0.79  
125QJ10-80 80 5.5 14.1 75.0 0.79  
125QJ10-104 104 7.5 19.0 76.0 0.79  
125QJ10-120 10 120 2850 60 50  125supra 7.5 380 19.0 76.0 0.79 118  
125QJ10-136 136 9.2 22.7 77.0 0.8  
125QJ15-36 15 36 2850 63 50  125supra 2.2 380 6.03 72.0 0.77 118  
125QJ15-39 39 3 8.01 73.0 0.78  
125QJ15-46 46 4 10.53 74.0 0.78  
125QJ15-52 52 4 10.53 74.0 0.78  
125QJ15-59 59 5.5 14.1 75.0 0.79  
125QJ15-65 65 5.5 14.1 75.0 0.79  
125QJ15-78 78 7.5 19.0 76.0 0.79  
125QJ15-91 91 7.5 19.0 76.0 0.79  
125QJ15-104 104 9.2 22.7 77.0 0.8  
125QJ20-16 20 16 2850 64 50  125supra 2.2 380 6.03 72.0 0.77 118  
125QJ20-24 24 3 8.01 73.0 0.78  
125QJ20-32 32 4 10.53 74.0 0.78  
125QJ20-40 40 4 10.53 74.0 0.78  
125QJ20-48 48 5.5 14.1 75.0 0.79  
125QJ20-56 56 5.5 14.1 75.0 0.79  
125QJ20-64 64 7.5 19.0 76.0 0.79  
125QJ20-72 72 7.5 19.0 76.0 0.79  
125QJ20-80 80 9.2 22.7 77.0 0.8  
125QJ25-12 25 12 2850 64 65  125supra 2.2 380 6.03 72.0 0.77 118  
125QJ25-18 18 3 8.01 73.0 0.78  
125QJ25-24 24 4 10.53 74.0 0.78  
125QJ25-30 30 4 10.53 74.0 0.78  
125QJ25-36 36 5.5 14.1 75.0 0.79  
125QJ25-48 48 7.5 19.0 76.0 0.79  
125QJ25-60 60 9.2 22.7 77.0 0.8  
125QJ32-24 32 24 2850 64 80  125supra 4 380 10.53 74.0 0.78 118  
125QJ32-30 30 5.5 14.1 75.0 0.79  
125QJ32-42 42 7.5 19.0 76.0 0.79  
125QJ32-54 54 9.2 22.7 77.0 0.8  
125QJ5-240 5 240 2850   40  125supra 11 380 26.28     118  
125QJ5-280 280 13 30.87      
125QJ5-320 320 15 35.62      
125QJ10-180 10 180 2850   50  125supra 11 380 26.28     118  
125QJ10-210 210 13 30.87      
125QJ10-240 240 15 35.62      
125QJ15-120 15 120 2850   50  125supra 11 380 26.28     118  
125QJ15-142 142 13 30.87      
125QJ15-162 162 15 35.62      
125QJ20-100 20 100 2850   50  125supra 11 380 26.28     118  
125QJ20-120 120 13 30.87      
125QJ20-136 136 15 35.62      
125QJ25-82 25 82 2850   65  125supra 11 380 26.28     118  
125QJ25-97 97 13 30.87      
125QJ25-110 110 15 35.62      
125QJ32-68 32 68 2850   80  125supra 11 380 26.28     118  
125QJ32-80 80 13 30.87      
125QJ32-92 92 15 35.62      
125QJ40-46 40 46 2850   80  125supra 11 380 26.28     118  
125QJ40-54 54 13 30.87      
125QJ40-62 62 15 35.62      

 

 
Salus Cautelae

1, well submersible pump for clean water pump, prohibit the new well, pumping sediment and muddy water,

2, well water pump voltage grade of 380/50HZ, the use of other voltage grades of submersible motors need to be customized. The underground cable must use waterproof cable, must be equipped with starting equipment, such as distribution box, start not ready should have commonly used motor comprehensive protection function, such as short circuit overload protection, phase protection, undervoltage protection, grounding protection, idling protection, in case of abnormal conditions, the protection device should be timely action trip.

3, the installation and use of the pump must be reliably grounded, prohibit the push and pull switch when the hands and feet are wet, the installation and maintenance of the pump must be cut off the power supply, the use of the pump place to set up "to prevent electric shock" obvious signs:

4, down the well or before installation, the motor cavity must be filled with distilled water or non-corrosive clean cold boiling water, tighten the / water bolt, the pump on the ground test run, must be to the pump chamber water lubrication rubber bearings, instant start not more than a second, see whether the steering is the same as the steering instructions. When the pump is upright, pay attention to safety, prevent overturning injury.

V, stricte secundum praescripta sentinae tollunt, fluunt usui, ne humilis fluat vel alta vi flare tollat, impulsus sustinens et alias partes indumenti, motor oneris combustus.

6, after the pump down the well, the measurement of the motor to the ground insulation resistance should not be less than 100M, after the start to observe the voltage and current, check the motor winding insulation, whether in line with the requirements; pump storage location temperature if less than freezing point, should be dry the motor cavity water, prevent the motor cavity water ice damage caused by low temperature.

 

 
Introductio ad Structuram

Brevis introductio structurae: pars sentinae maxime componitur ex stipite sentinali, impulsore, putamine diversio, globulus portante, valvae corporis (partes ad libitum) et alia membra inspicienda. Pars motor maxime composita ex basi, pressione cinematographico moderante, bracteae impulsus portans, fixurae laminae, dux inferior sedem gerens, stator, rotor, dux superior sedem gerens, annulum harenae, aqua limbum sectio, funem et alia elementa.


Pelagus features productum includit:

 I, motor aquaticus plenus humidus submersibilis asynchronous motor tres phase asynchronous motor est, cavitatis motoriae plena est aqua munda, ad refrigerandum motorem et praeligatum ferentem, pressionis cinematographicae in fundo motoris moderatae aptando. ex expansione et contractione pressionis differentiae aquae intra corpus causatum ex mutatione caliditatis oriuntur motoris.

 2, Ut arena in puteo aquae motoris ne ingrediatur, superior finis motoris scapus duobus sigillis olei instructus est, et anulus arenarius instituitur ad structuram arcendam ne structuram formandam.

 3, Ad ne scapi sentinam excurrere incipiendo, scapi sentinae et scapus motoriis coitu inter se conexi sunt, superiorque impulsus in inferiore parte motoris instituitur.

 IV, lubricatio motoris et sentinae afferentis est aqua lubricatio.

 5, Motor stator coluber factus est altae qualitatis filum flexuosum submersibile, cum magna operatione velit.

 VI, Sentina ab computatrum CAD designatur, cum simplici structura et operatione technica bona.

 
install

(I) Praeparatio ante institutionem:
1. Perspice an sentinam submersibilem usui conditionibus occurrat et ambitum in manuali definitum.
2. Utens obiectu gravi cum diametro aequali maximo diametro exterioris sentinae submersibilis, metire an inneldiametri putoris sentinam submersibilem aptare possit, et metire an puteus profundus ad institutionem requisita occurrat.
3. Reprehendo utrum puteus mundus sit, et si puteus aqua turbidus est. Numquam uti sentinam electricam submersibilem ad lavandum putorem sentinam lutum et aquam arenam ad vitandum praematurum damnum ad sentinam electricam submersibilem.
4. Reprehendo an positio fibulae institutionis welhead sit conveniens et an qualitatem totius unitatis sustinere possit
5. Reprehendo si partes sentinae submersibiles sint perfectae et rite institutae secundum schematis conventus in manu-Removeo velum colum et gyrari queat ad videndum an mollius circumagatur.
6. Aquam cochleae et cavum mobilem reple, non mordax aqua (ex corrosivis (vide ut eam sursum), tum obstringas aqualram. Post 12 horas aquae injectiones, insulatio motoris resistentia non minus quam 150M Q mensurata est cum 500V tabula quatiens.
7. Cable iuncturam, globulus manica 120mm abscindens ab extremo e fune exeuntis et adaptans funem cum cultello electriciano vacillat longitudine trium filorum nucleorum in figura calcatae, decoriabit 20mm nucleum cupri, rade oxydi. iacuit extrinsecus filum aeneum cum cultello vel panno arenario, et inseres duas filis connexis in palirs. Postea ligans lauacrum arcte cum filo cupreo, solidatur illud penitus et firmiter, et arena cuiuslibet. silua in superficie. Deinde tres articulos, polyvestrum taeniola utere, ut eas in modum semi reclinatum pro tribus labris involvas. Involve ad duos terminos stratis ligaturae tightywith nyion stamina, et deinde utere modum reclinatum semi reclinatum ad machinam trium ordinum involvere. Involve exterius cum summus pressura velit machinae tres ordines. Denique ternas plicas simul et eas identidem involvunt pro quinque laminis cum taenia alta pressura. Singulae tabulae arcte ligatae esse debent, et articuli interpositi stricta et fimm debent esse ne aqua in velitationem penetrare et laedere, Involutione, aqua macerari in cella temperie 20'c per 12 horas, et metiare velit resistentiam cum mensa quatiente. quod non debet esse minus quam 100M Ω .

 

Adnexa funis processus schematis wiring talis est:

 

8. Multimetro utere ad reprimendam num tria-phasma fila connexa sint et an resistentia DC proxime libratum sit.
9. Perscriptio num ambitus et transformantis capacitas cumulatur, et tunc coniunge cum onere transitum tutelae vel apparatum incipiens. Vide Tabulam 2 ad exempla specifica, et mitte situlam aquae in sentinam aquae ex aqua sentinae exitum ad praestringendum iuvantis gestus in sentinam, et pone sentinam submersibilem electricam erectam et constantem.Start (non plus quam unum secundum) et vide utrum directio gubernii sit cum signo gubernaculo consonans. Sin minus, aliquos duos connexiones trium-phase cables permuto. Deinde colum inaugurare et ad puteum descendere parant. Si in peculiaribus occasionibus adhibeantur (sicut fossae, fossae, flumina, stagna, stagna, etc.), sentinam electricam certo fundari debent.

 

(2) Installation instrumentorum et instrumentorum;
1. Unum par catenarum levandi plus duobus talentis.
2. Tripode cum perpendiculo non minus quam quattuor metra.
3. Duo funes suspensi (funes filum) qui pondus plus quam unum ton ferre possunt (pondere aquae soleatus completae).
4. duo paria fibulatorum inaugurare (facile).
5. Clavis, malleis, verticillis, instrumentis electricis et instrumentis, etc.

 

(III) Electric sentinam institutionem:
1. Tabulae institutionis sentinae submersibilis electrici in Figura ostenditur 2. Specificae institutiones dimensiones in Tabula 3 monstrantur "Index institutionis Dimensiones Submersible Electric Pump".

 

2. Solatus electrici submersibiles cum capite minore quam 30 metra directe levari possunt in puteum caligarum et funiculos filum vel alias funiculos cannabinos, qui plenum pondus totius machinae, fistulae aquae et aquae in tibiis ferre possunt.

 

3. Pumps cum capite plusquam 30 metrorum utimur fistulis ferreis, et series institutionis haec est:
① Fibulae utere ad fibulae partem superiorem sentinam aquae (motricis et aquae sentinae hoc tempore coniunctae sunt), eam cum cathena pensili tolle, et lente eam in puteum ligabis, donec Fibulae in putei caput auferas et removeas. catena pendula.
② Alterum par fibularum utere ad fistulam fibulae, eam leva cum cathena pendula 15 cm a LABIUM, et lente deprime. Inter fistulam LABIUM et sentinam flangePut Flexilis caudex in loco, et obstringere tibiam et sentinam aequabiliter cum valvis, nucibus et lavatoribus veris.
③ Sentinam submersibilem leviter tolle, fibulam in superiore fine aquae sentinae tolle, funem ligabis ad fistulam aquae cum taenia plastica firmiter, et lente ligabis eam donec Fibulae ad putei caput ponatur.
Eadem methodo omnes aquae fistulas in puteum alligant.
⑤Post funem plumbeum ad imperium transitum coniungitur, cum copia trium phase iungitur.


(4.) Notae in installation:
1. Si vallum phaenomenon in flantibus processum inveniatur, vertere vel fistulam aquam trahere, ut punctum vallum superetur. Si variae mensurae adhuc non operantur, quaeso Noli sentinam cogere ad vitandum damnum in sentinam electricam et puteum submersibilem.
2. In institutione, codex iuvantis ad cuiusque fistulae LABIUM collocari debet et aequaliter coarctari.
3. Cum aqua sentina in puteum demissa, in media fistula putei poni debet, ne sentinam contra murum putei diu curreret, sentinam pulsum et motorem verrere et comburere. .
4. Determinare profunditatem aquae sentinae ad imum putei iuxta arenam fluentem et condiciones putei limum. Sentinam in luto non sepelias. Distantia aquae sentinae ad fundum putei fere non minus quam 3 metra (vide figura 2).
5. Aquae viscus profunditas aquae sentinae non minus esse debet quam 1-1.5 metra a gradu aquae dynamicae ad nodi aquae diverticulum (vide Figure 2). Alioquin aquae sentinae gestus facile laedantur.
6. Aquae levare sentinam nimis humilis esse non potest. Alioquin valvae portae aquae putei fistulae inaugurari debet ut fluere sentinam fluere apud punctum aestimatum fluere prohibeat ne motor oneretur et exuratur propter magnas rates fluxus.
7. Cum aqua currit sentina, aqua output continuum et par esse debet, currens sit stabilis (sub condiciones operationis aestimatae, plerumque non plus quam 10% currentis aestimatae), nec vibratio nec strepitus esse debet. Si qua deprauatio est, machina cessari debet causam cognoscendi et removendi.
8. Cum inaugurari, attende ad occasum filum fundationis motoris (vide Figure 2). Fistula cum aqua est ferrea tibia, a puteo fibulato duc; cum fistula aquatica fistula plastica est, eam a fundamento sentinae electrici notam duc.

 

 
Tutela et sustentationem
  • 1. Post sentinam submersibilem inauguratur, velit resistentia et tres phases conductionis ex switch iterum retentare, inspicias num instrumentum et nexum instrumentorum initii fallant, si dubium non est, machina temptatio inchoari potest; et vide an lectiones instrumenti indicativi excedant intentionem aestimatam et currentem in nominato post initium determinatam, et vide an sentinam habeat phaenomenon strepitum et vibrationem, et in operando si omnia normalia sunt.
  • 2. Post primam sentinam operationem per quattuor horas, motor occlusus debet esse ad resistentiam scelerisque velitandi explorandam cito, eiusque valor non minus quam 0.5 megaohm esse debet.
  • 3. Post occlusam sentinam, incepit post quinque minutas ne columna aqua in tibia omnino refluxit et causans excessus motoris et burnout.
  • 4. Post sentinam in operationem normalem ponatur, ut vitam suam proroget, necesse est ut inspicias an copia intentionum, currentium et velitium resistentiae normales regulariter sint. Si sequentes condiciones inveniantur, antliae statim ad troubleshoot claudenda.
  •  
  • - In conditione aestimata, hodierna 20% excedit.
  • — Aquae dynamicae in gradu aquae guttae ad sectio limbi aquae causando aquam intermissam.
  • - Sentinam submersibilem habet gravem vibrationem vel strepitum.
  • — Copia intentionis infra 340 voltas est.
  • — A fuse exuritur.
  • — Aquarum fistula laeditur.
  • - Nulla resistentia scelerisque motoris minor est quam 0,5 megaohm.
  •  
  • Unit disassembly:
  • (1)Untie the cable tie, remove the pipeline part, and remove the wire plate.
  • (2)screw down the water bolt, put the water in the motor chamber.
  • (3)remove the filter, loose the fixed screw on the coupling to fix the motor shaft.
  • (4)screw down the bolt connecting the water inlet section with the motor, and separate the pump from the motor (pay attention to the unit cushion when separating, to prevent the bending of the pump shaft)
  • (5)the disassembly sequence of the pump is: (see figure 1) water inlet section, impeller, diversion shell, impeller...... check valve body, when removing the impeller, use special tools to loosen the conical sleeve of the fixed impeller first, and avoid bending and bruising the pump shaft in the process of disassembly.
  • (6)the disassembly process of the motor is: (see figure 1) place the motor on the platform, and remove the nuts, base, shaft head locking nut, thrust plate, key, lower guide bearing seat and double head bolt from the bottom of the motor in turn, and then take out the rotor (pay attention not to damage the wire package) and finally remove the connecting section and upper guide bearing seat.
  • (7)unit assembly: before assembly, the rust and dirt of the parts should be cleaned, and the mating surface and fasteners coated with sealant, and then assembled in the opposite order of disassembly (the motor shaft moves up and down after assembly for about one millimeter), after assembly, the coupling should be flexible, and then the filter screen test machine. Submersible pumps shall be taken out of the well for dismantling and maintenance according to Article 5 after a year of operation, or less than a year of operation but two years of diving time, and the worn parts shall be replaced.
  •  
 
Repono et custodiam

 I, aquam in cavo motorio extingue (praesertim hieme ne motor a frigore) et funem bene ligaveris.

 2, repone in cella involucri sine substantiis et vaporibus corrosivis, cum temperatura infra 40 °C.

 III, diu terminus usus observandum ne rubigo soleatus submersible.

 

 
Partibus gerens
  • Impeller
  • hastile sleeve
  • Flexilis scapus sleeve
  • signantes anulum

 
Application missiones

I Aquam profunda bene attractio

II High-surgere aquarum copia

03 mons aquae copia 

04 aqua turris

05 Irrigatio agriculturae

VI hortus irrigationis

07 attractio aquae fluminis

08 aqua domestica

 

Si interest in productis nostris, informationes tuas hic relinquere potes, et tecum brevi tactus erimus.


Epistulam tuam hic scribe et mitte nobis

Si interest in productis nostris, informationes tuas hic relinquere potes, et tecum brevi tactus erimus.


laLatin