Usus aquae motoris submersibilis immersae, rotor indumentorum resistentium admixto manica et stannum impulsu discus design. More durabilis quam (oleum flexuosum immersum, rotor portans motorem), magis environmentally- amica. Nulla lacus oleum post defectum sentinae, nulla pollutio. bene aqua, tutius usus. Circulus impulsor utens altae fortitudinis anti-sandae gerunt obsistentes PC materiae polymerorum compositarum, nova tria dimensiva hydraulica designatio, impulsor fluitans, structurae ceramicae anti-sandrae resistentia, plena levare, magna fluens. motor altitudinem 300 metrorum intendere potest.
This product is a three-phase AC 380V (tolerance ± 5%), 50HZ (tolerance ± 1%) power supply system, designed for strict water quality requirements. The product is suitable for water temperature not higher than 20 °C, solid impurities content (mass ratio) is not greater than 0.01%, PH value (pH) between 6.5-8.5, hydrogen sulfide content is not greater than 1.5mg/L, chloride ion content is not greater than 400mg/L environment. This product is equipped with a closed or water-filled wet structure motor, before use must be submersible motor inner cavity filled with clean water to prevent false full, and then tighten the water and air bolts, otherwise not to use. The submersible pump must be completely immersed in water to work, penetration depth shall not exceed 70 meters, the distance from the bottom of the pump to the bottom of the well shall not be less than 3 meters. In addition, the well water flow should meet the continuous operation requirements of the submersible pump, the water output of the submersible pump should be controlled at 0.7-1.2 times the rated flow. When used, the well must be vertical, and the submersible pump can not be used horizontally or dumped, only vertical installation. To ensure safety, the submersible pump must match the cable according to the requirements and be equipped with external overload protection device, and it is strictly prohibited to conduct no-load test on the pump without water. This product is an ideal choice for providing high quality water source, and can be widely used in various industrial and civil water processing fields.
105QJ series water-filled stainless steel deep well pump |
|||||
Model |
Fluere m³/h |
Caput (m) |
Motor Potestas (KW) |
Unitas diametri (mm) |
diameter (mm) |
105QJ2-230/36 |
2 |
230 |
4kw |
103 |
105 |
105QJ2-300/50 |
300 |
5.5kw |
|||
105QJ2-390/65 |
390 |
7.5kw |
|||
105QJ4-50/10 |
4 |
50 |
1.1kw |
103 |
105 |
105QJ4-60/12 |
60 |
1.5kw |
|||
105QJ4-80/16 |
80 |
2.2kw |
|||
105QJ4-100/20 |
100 |
3kw |
|||
105QJ4-140/28 |
140 |
4kw |
|||
105QJ4-200/40 |
200 |
5.5kw |
|||
105QJ4-275/55 |
275 |
7.5kw |
|||
105QJ6-35/10 |
6 |
35 |
1.1kw |
103 |
105 |
105QJ6-40/12 |
40 |
1.5kw |
|||
105QJ6-60/16 |
60 |
2.2kw |
|||
105QJ6-75/20 |
75 |
3kw |
|||
105QJ6-105/28 |
105 |
4kw |
|||
105QJ6-140/40 |
140 |
5.5kw |
|||
105QJ6-192/55 |
192 |
7.5kw |
|||
105QJ8-25/5 |
8 |
25 |
1.1kw |
103 |
105 |
105QJ8-40/8 |
40 |
1.5kw |
|||
105QJ8-55/11 |
55 |
2.2kw |
|||
105QJ8-75/15 |
75 |
3kw |
|||
105QJ8-95/19 |
95 |
4kw |
|||
105QJ8-125/25 |
125 |
5.5kw |
|||
105QJ8-160/32 |
160 |
7.5kw |
|||
105QJ10-20/5 |
10 |
20 |
1.1kw |
103 |
105 |
105QJ10-30/8 |
30 |
1.5kw |
|||
105QJ10-40/11 |
40 |
2.2kw |
|||
105QJ10-55/15 |
55 |
3kw |
|||
105QJ10-75/19 |
75 |
4kw |
|||
105QJ10-90/25 |
90 |
5.5kw |
|||
105QJ10-120/32 |
120 |
7.5kw |
|||
105QJ16-22/9 |
16 |
22 |
2.2kw |
103 |
105 |
105QJ16-28/12 |
28 |
3kw |
|||
105QJ16-35/15 |
35 |
4kw |
|||
105QJ16-50/20 |
50 |
5.5kw |
|||
105QJ16-68/27 |
68 |
7.5kw |
130QJ series water-filled stainless steel deep well pump |
|||||
Model |
Fluere m³/h |
Caput (m) |
Motor Potestas (KW) |
Unitas diametri (mm) |
diameter (mm) |
130QJ10-60/7 |
10 |
60 |
1.5kw |
130 |
135 |
130QJ10-80/12 |
80 |
2.2kw |
|||
130QJ10-100/15 |
100 |
3kw |
|||
130QJ10-130/20 |
130 |
4kw |
|||
130QJ10-160/25 |
160 |
5.5kw |
|||
130QJ10-220/32 |
220 |
7.5kw |
|||
130QJ10-250/38 |
250 |
9.2kw |
|||
130QJ10-300/42 |
300 |
11kw |
|||
130QJ10-350/50 |
350 |
13kw |
|||
130QJ10-400/57 |
400 |
15kw |
|||
130QJ10-450/64 |
450 |
18.5kw |
|||
130QJ10-500/70 |
500 |
22kw |
|||
130QJ15-40/5 |
15 |
40 |
1.5kw |
130 |
135 |
130QJ15-50/7 |
50 |
2.2kw |
|||
130QJ15-60/10 |
60 |
3kw |
|||
130QJ15-80/12 |
80 |
4kw |
|||
130QJ15-105/15 |
105 |
5.5kw |
|||
130QJ15-150/22 |
150 |
7.5kw |
|||
130QJ15-170/25 |
170 |
9.2kw |
|||
130QJ15-200/28 |
200 |
11kw |
|||
130QJ15-240/34 |
240 |
13kw |
|||
130QJ15-280/40 |
280 |
15kw |
|||
130QJ15-300/42 |
300 |
18.5kw |
|||
130QJ15-336/48 |
336 |
18.5kw |
|||
130QJ15-350/50 |
350 |
22kw |
|||
130QJ15-400/56 |
400 |
22kw |
130QJ series water-filled stainless steel deep well pump |
|||||
Model |
Fluere m³/h |
Caput (m) |
Motor Potestas (KW) |
Unitas diametri (mm) |
diameter (mm) |
130QJ20-22/3 |
20 |
30 |
2.2kw |
130 |
135 |
130QJ20-30/5 |
42 |
3kw |
|||
130QJ20-42/6 |
54 |
4kw |
|||
130QJ20-52/8 |
65 |
5.5kw |
|||
130QJ20-72/11 |
85 |
7.5kw |
|||
130QJ20-90/14 |
110 |
9.2kw |
|||
130QJ20-105/16 |
128 |
11kw |
|||
130QJ20-130/19 |
145 |
13kw |
|||
130QJ20-150/22 |
164 |
15kw |
|||
130QJ20-182/27 |
182 |
18.5kw |
|||
130QJ20-208/31 |
208 |
22kw |
|||
130QJ20-240/35 |
240 |
25kw |
|||
130QJ20-286/42 |
286 |
30kw |
|||
130QJ25-35/6 |
25 |
35 |
3kw |
130 |
135 |
130QJ25-40/7 |
40 |
4kw |
|||
130QJ25-52/9 |
52 |
5.5kw |
|||
130QJ25-70/12 |
70 |
7.5kw |
|||
130QJ25-85/15 |
85 |
9.2kw |
|||
130QJ25-105/18 |
105 |
11kw |
|||
130QJ25-120/21 |
120 |
13kw |
|||
130QJ25-140/24 |
140 |
15kw |
150QJ series water-filled stainless steel deep well pump |
|||||
Model |
Fluere m³/h |
Caput (m) |
Motor Potestas (KW) |
Unitas diametri (mm) |
diameter (mm) |
150QJ12-40/3 |
12 |
40 |
2.2kw |
143 |
150 |
150QJ12-55/5 |
55 |
3kw |
|||
150QJ12-80/7 |
80 |
4kw |
|||
150QJ12-107/9 |
107 |
5.5kw |
|||
150QJ12-142/11 |
142 |
7.5kw |
|||
150QJ12-175/14 |
175 |
9.2kw |
|||
150QJ12-200/16 |
200 |
11kw |
|||
150QJ12-242/19 |
242 |
13kw |
|||
150QJ12-268/21 |
268 |
15kw |
|||
150QJ12-293/23 |
293 |
18.5kw |
|||
150QJ20-28/3 |
20 |
28 |
3kw |
143 |
150 |
150QJ20-48/5 |
48 |
4kw |
|||
150QJ20-70/7 |
70 |
5.5kw |
|||
150QJ20-90/9 |
90 |
7.5kw |
|||
150QJ20-107/11 |
107 |
9.2kw |
|||
150QJ20-135/14 |
135 |
11kw |
|||
150QJ20-155/16 |
155 |
13kw |
|||
150QJ20-175/18 |
175 |
15kw |
|||
150QJ20-195/20 |
195 |
18.5kw |
|||
150QJ20-220/22 |
220 |
18.5kw |
|||
150QJ20-235/25 |
235 |
22kw |
|||
150QJ20-255/28 |
255 |
25kw |
150QJ series water-filled stainless steel deep well pump |
|||||
Model |
Fluere m³/h |
Caput (m) |
Motor Potestas (KW) |
Unitas diametri (mm) |
diameter (mm) |
150QJ45-18/2 |
45 |
18 |
4KW |
143 |
150 |
150QJ45-28/3 |
28 |
5.5KW |
|||
150QJ45-46/5 |
46 |
7.5KW |
|||
150QJ45-57/6 |
57 |
9.2KW |
|||
150QJ45-65/7 |
65 |
11KW |
|||
150QJ45-75/8 |
75 |
13KW |
|||
150QJ45-90/10 |
90 |
15KW |
|||
150QJ45-108/12 |
108 |
18.5KW |
|||
150QJ45-125/14 |
125 |
22KW |
|||
150QJ45-145/16 |
145 |
25KW |
|||
150QJ45-168/18 |
168 |
30KW |
|||
150QJ32-20/2 |
32 |
20 |
3kw |
143 |
150 |
150QJ32-30/3 |
30 |
4kw |
|||
150QJ32-43/4 |
43 |
5.5kw |
|||
150QJ32-60/5 |
60 |
7.5kw |
|||
150QJ32-65/6 |
65 |
7.5kw |
|||
150QJ32-75/7 |
75 |
9.2kw |
|||
150QJ32-85/8 |
85 |
11kw |
|||
150QJ32-100/9 |
100 |
13kw |
|||
150QJ32-110/10 |
110 |
15kw |
|||
150QJ32-118/11 |
118 |
18.5kw |
|||
150QJ32-140/13 |
140 |
18.5kw |
|||
150QJ32-155/15 |
155 |
22kw |
|||
150QJ32-185/18 |
185 |
25kw |
|||
150QJ32-215/21 |
215 |
30kw |
This kind of well submersible pump is a clean water pump. It is strictly prohibited to dig new wells and extract sediments and turbid water. The voltage grade of the well pump is 380/50HZ. The submersible motor with other voltage grades needs to be customized. Underground cables must be waterproof cables and must be equipped with starting equipment, such as distribution box, etc. The starting equipment should have common comprehensive motor protection functions, such as short circuit overload protection, phase loss protection, undervoltage protection, grounding protection and idling protection, etc., to prevent timely tripping when abnormal conditions occur. The pump must be reliably grounded during installation and use, and it is strictly prohibited to push and pull the switch when the hands and feet are wet. The power supply must be cut off before installation and maintenance of the pump. The place where the pump is used must be set up with obvious "anti-electric shock" marks. Before going down the well or installation, the motor must be filled with distilled water or non-corrosive clean cold water in the internal chamber, and the drain bolt must be fastened. When testing the pump on the ground, water must be injected into the pump chamber to lubricate the rubber bearings. The instantaneous start time shall not exceed one second to check whether the direction is correct, and the direction is the same as the direction indicator. When the pump is erected, pay attention to safety to prevent injury from tilting. Strictly in accordance with the provisions of the pump lift and flow range of use, to avoid the pump in the low flow when the large flow or in the high lift appears in the large pull, resulting in extreme wear of thrust bearings and other components, the motor overload and burn. After the pump into the well, the insulation resistance between the motor and the ground should be measured, not less than 100MΩ. After the start, regular observation of voltage and current, and check whether the motor winding insulation meets the requirements of the provisions. If the location temperature of the pump storage is below the freezing point, the water in the motor cavity should be drained, so as not to damage the motor in winter low temperature freezing.
- 1.Submersible institutionem sentinam integram esse, resistentiam re-reprehende et tres phases conductionis ex switch, instrumento coercere et nexum instrumentorum incipere erroris, si dubium non est, iudicium incipere potest post instrumenti initium. indicantes lectiones num plus quam nominatus stipulatus sit æstimatio et currens, animadverte phaenomenon sentinam strepitum et vibrationem, omnia normalia in exer mitti possunt.
- 2. Prima operatio sentinae per quattuor horas occlusa debet cito temptare resistentiam scelerisque motoris, valor non minor quam 0.5 megaohm.
- 3. Post clausuram sentinam inchoari debet post quinque minutas intervalla, ne columna aqua in tibia refluxus motoris et burnout omnino non causetur.
- 4. Post sentinam in operationem normalem, ut vitam servitutis prolonget, copiam intentionis ad reprimendam, currenti et velit resistentiae laboranti normale est, si condicionem sequentem inveneris, statim claudat sollicitudinem.
1 in conditione aestimata, praesens plus quam 20% est.
2 aqua dynamica, planities aquae limbi sectio, aqua intermissa causans.
3 sentinam submersibilem seu tremulum seu sonum gravem.
4 copia intentione infra 340 voltas est.
V pascha fuse exstinctae sunt.
VI fistulae aquarum damnum.
7 motor ad resistentiam scelerisque velitarum minor quam 0.5 megaohm.
- 5.Unit disassembly:
I ligamen ligamen, partem fistulam remove, laminam filum remove.
2 cochleae aquam fulmine deprime, aquam in camera motoria pone.
3 colum remove, cochleam fixam solve in junctura, figere vectem motoriam.
4 cochleae descendit fulmen cum sectione motore aquam connectens limbum, et sentinam a motore separa (attende ad pulvinum unitatis cum secernendo, ne inflexio scapi sentinae)
5 disassembly series sentinae est: (vide figuram 1) aqua limbi sectio, impulsor, diversio putamen, impulsor ....... corpus valvae reprehendo, impulsor removens, specialia instrumenta adhibent ad manicam fixarum conicam solvendam. impulsor primus, neve inflectens et sentinam stipitem in processu disassemble contundere.
6 disassembly processus motoris est: (vide figure 1) motorem in suggestu ponere, ac nuces basi tollere, hastile caput nucis densis, laminam clavem impellere, clavem inferiorem duce sede gestans et duplex caput fulmen ab imo. in vicem motoris, et deinde rotor (animadverte ne sarcinam filum laedas) tollas et demum sectionem connectentem et ductorem superiorem sedem gestantem removeas.
7 unitas conventus: ante ecclesiam, aerugo et sordes partium purgari debent, et superficies coitus et fasteners obductis sealant, et deinde in opposito ordine disassemble congregantur (scapus motor movens sursum et deorsum post conventum circiter unum. millimetre), post conventum, coniunctio flexibilis esse debet, et postea machina emissarium velamentum test. Soleatus submersibiles accipientur e puteo ad distrahendum et sustentandum secundum Articulum 5 post annum operationis, vel minus quam annus operationis, sed biennium tempus tribuendi, et partes attritae reponentur.
Hoc productum est sentinam electricam submersibilis cum praestanti effectu. Unicum eius consilium variis occasionibus usibus aptum est. Utrum motor hiemem in frigore prohibeat vel ne rubiginem cum diu non adhibeatur, haec sentina submersibilis electrica tuis necessariis ad apparatum sustentationem occurrere potest. Simplex est ad operandum, et conveniens ad conservandum. Iuste vestigia sequi in manu manuali ad rectam sustentationem et repono, quae efficaciter possunt prorogare vitam servitii producti. Accipe hanc sentinam electricam submersibilem nunc et fac opus tuum levius et efficacius!
I Aquam profunda bene attractio
II High-surgere aquarum copia
03 mons aquae copia
04 aqua turris
05 Irrigatio agriculturae
VI hortus irrigationis
07 attractio aquae fluminis
08 aqua domestica