Designed for underground hot water mining below 100°C, this product has the characteristics of high temperature resistance, corrosion resistance and aging resistance. Whether in underground mining or other hot water environment applications, it can effectively resist the challenges of harsh environment. Its excellent performance and stable quality make it an ideal choice in the mining field.

 

 
Conditiones usus

1, potestas supple: three-phase AC 380V (tolerantia + / - 5%), 50HZ (tolerantia + / - 1%).

2, aquae qualitate;

(1) water temperature is not higher than 20 °C;

(2) immunditia solida contenta (ratio massae) non maior est quam 0.01%;

(3) PH valorem (pH) 6.5-8.5;

(4) hydrogenii sulfidelis contentum 1.5mg/L majus non est;

(5) Ion contentum chloridum maius 400mg/L non est.

III, motor clauditur vel aqua repleta humida structura, antequam uti cavitas submersibilis motoris plena sit aqua munda, ne falsa plena sit, et deinde aqua infusione obstringere, aere emittere fulmina, secus uti non licet.

IV, sentinam submersibilem penitus demergi debet in aqua, urinarum profunditas non est maior quam 70m, imo sentina submersibilis ab imo putei non minus quam 3m.

V, puteus aquae fluxus in sentinam aquae submersibilis output et operationem continuam occurrere possit, sentinae aquae output submersibilis coerceri debet ad 0.7 - 1.2 temporibus fluxus aestimatus.

VI, puteus rectum esse, sentinam submersible vel rasurae adhiberi non potest, tantum verticali usu.

VII, sentinam submersibilem aequare oportet cum fune secundum exigentias, et externam fabricam tutelae cultro. VIII, sentinam sine aqua nullo onere test apparatus stricte prohibetur

 

 
Model Meaning

150QJR Deep Well Submersible Pump

 
Partialis Model Reference
Model Flow (m3/h) Caput
(m)

Rotatingspeed

(Mutatio / punctum)

Aqua sentinam(%)  Outlet
diametri
(mm)
Lorem bene
diametri (mm) 
 Ratum
potestas(KW)
Ratum
voltage(V)
Ratum
current (A *
Motorefficiency (%) power factorcosφ   Unitas
Aculeis Maximus amplitudo (mm)
Animadverte
150QJ5-100 5 100 2850 58 40 150 3 380 7.9 74.0 0.78 143  
150QJ5-150 5 150 2850 58 40  150above 4 380 10.25 75.0 0.79 143  
150QJ5-200 200 5.5 13.74 76.0 0.8  
150QJ5-250 250 7.5 18.5 77.0 0.8  
150QJ5-300 300 9.2 22.12 78.0 0.81  
150QJ10-50 10 50 2850 63 50  150supra 3 380 7.9 74.0 0.78 143  
150QJ10-66 66 4 10.25 75.0 0.79  
150QJ10-78 78 4 10.25 75.0 0.79  
150QJ10-84 84 5.5 13.74 76.0 0.8  
150QJ10-91 91 5.5 13.74 76.0 0.8  
150QJ10-100 100 5.5 13.74 76.0 0.8  
150QJ10-128 128 7.5 18.5 77.0 0.8  
150QJ10-150 150 7.5 18.5 77.0 0.8  
150QJ10-200 200 11 26.28 78.5 0.81  
150QJ10-250 250 13 30.87 79.0 0.81  
150QJ10-300 300 15 35.62 79.0 0.81  
150QJ15-33 15 33 2850 63 50  150supra 3 380 7.9 74.0 0.78 143  
150QJ15-42 42 4 10.25 75.0 0.79  
150QJ15-50 50 4 10.25 75.0 0.79  
150QJ15-60 60 5.5 13.74 76 0.8  
150QJ15-65 65 5.5 13.74 76.0 0.8  
150QJ15-72 72 5.5 13.74 76.0 0.8  
150QJ15-81 81 7.5 18.5 77.0 0.8  
150QJ15-90 90 7.5 18.5 77.0 0.8  
150QJ15-98 98 7.5 18.5 77.0 0.8  
150QJ15-106 106 9.2 22.12 78.0 0.81  
150QJ15-114 114 9.2 22.12 78.0 0.81  
150QJ15-130 130 11 26.28 78.5 0.81  
150QJ15-146 146 13 30.87 79.0 0.81  
150QJ15-162 162 13 30.87 79.0 0.81  
150QJ15-180 180 15 35.62 79.0 0.81  
150QJ20-26 20 26 2850 64 50  150supra 3 380 7.9 74.0 0.78 143  
150QJ20-33 33 3 7.9 74.0 0.78  
150QJ20-39 20 39 2850 64 50  150supra 4 380 10.25 75.0 0.79 143  
150QJ20-52 52 5.5 13.74 76.0 0.8  
150QJ20-65 65 7.5 18.5 77.0 0.8  
150QJ20-78 78 7.5 18.5 77.0 0.8  
150QJ20-91 91 9.2 22.12 78.0 0.81  
150QJ20-98 98 9.2 22.12 78.0 0.81  
150QJ20-104 104 11 26.28 78.5 0.81  
150QJ20-111 111 11 26.28 78.5 0.81  
150QJ20-130 130 13 30.87 79.0 0.81  
150QJ20-143 143 13 30.87 79.0 0.81  
150QJ20-156 156 15 35.62 79.0 0.81  
150QJ20-182 182 18.5 43.12 79.5 0.82  
150QJ25-24 25 24 2850 64 65  150supra 3 380 7.9 74.0 0.78 143  
150QJ25-32 32 4 10.25 75.0 0.79  
150QJ25-40 40 5.5 13.74 76.0 0.8  
150QJ25-48 48 5.5 13.74 76.0 0.8  
150QJ25-56 56 7.5 18.5 77.0 0.8  
150QJ25-64 64 7.5 18.5 77.0 0.8  
150QJ25-72 72 9.2 22.12 78.0 0.81  
150QJ25-77 77 9.2 22.12 78.0 0.81  
150QJ25-84 84 11 26.28 78.5 0.81  
150QJ25-96 96 11 26.28 78.5 0.81  
150QJ25-104 104 13 30.87 79.0 0.81  
150QJ25-110 110 13 30.87 79.0 0.81  
150QJ25-120 120 15 35.62 79.0 0.81  
150QJ25-128 128 15 35.62 79.0 0.81  
150QJ25-136 136 18.5 43.12 79.5 0.82  
150QJ25-154 154 18.5 43.12 79.5 0.82  
150QJ32-18 32 18 2850 66 80  150supra 3 380 7.9 74.0 0.78 143  
150QJ32-24 24 4 10.25 75.0 0.79  
150QJ32-30 30 5.5 13.74 76.0 0.8  
150QJ32-36 36 5.5 13.74 76.0 0.8  
150QJ32-42 32 42 2850 66 80  150supra 7.5 380 18.5 77.0 0.8 143  
150QJ32-54 54 9.2 22.12 78.0 0.81  
150QJ32-66 66 11 26.28 78.5 0.81  
150QJ32-72 72 13 30.87 79.0 0.81  
150QJ32-84 84 13 30.87 79.0 0.81  
150QJ32-90 90 15 35.62 79.0 0.81  
150QJ32-96 96 15 35.62 79.0 0.81  
150QJ32-114 114 18.5 43.12 79.5 0.82  
150QJ40-16 40 16 2850 66 80  150supra 3 380 7.9 74.0 0.78 143  
150QJ40-24 24 5.5 13.74 76.0 0.8  
150QJ40-30 30 5.5 13.74 76.0 0.8  
150QJ40-40 40 7.5 18.5 77.0 0.8  
150QJ40-48 48 9.2 22.12 78.0 0.81  
150QJ40-56 56 11 26.28 78.5 0.81  
150QJ40-64 64 13 30.87 79.0 0.81  
150QJ40-72 72 13 30.87 79.0 0.81  
150QJ40-80 80 15 35.62 79.0 0.81  
150QJ40-96 96 18.5 43.12 79.5 0.82  
150QJ50-16 50 16 2850 65 80  150supra 4 380 10.25 75.0 0.79 143  
150QJ50-22 22 5.5 13.74 76.0 0.8  
150QJ50-28 28 7.5 18.5 77.0 0.8  
150QJ50-34 34 9.2 22.12 78.0 0.81  
150QJ50-40 40 9.2 22.12 78.0 0.81  
150QJ50-46 46 11 26.28 78.5 0.81  
150QJ50-52 52 13 30.87 79.0 0.81  
150QJ50-57 57 15 35.62 79.0 0.81  
150QJ50-74 74 18.5 43.12 79.5 0.82  
150QJ50-80 80 18.5 43.12 79.5 0.82  
150QJ63-12 63 12 2850 60 80  150supra 4 380 10.25 75.0 0.79 143  
150QJ63-18 18 7.5 18.5 77.0 0.8  
150QJ63-30 30 9.2 22.12 78.0 0.81  
150QJ63-36 36 11 26.28 78.5 0.81  
150QJ63-42 63 42 2850 60 80  150supra 13 380 30.87 79.0 0.81 143  
150QJ63-48 48 15 35.62 79.0 0.81  
150QJ63-54 54 18.5 43.12 79.5 0.82  
150QJ15-220 15 220 2850   50  150supra 18.5 380 43.12     143  
150QJ15-260 260 20 49.7      
150QJ15-300 300 25 56.5      
150QJ20-210 20 210 2850   50  150supra 20 380 49.7     143  
150QJ20-240 240 25 56.5      
150QJ20-290 290 30 66.6      
150QJ25-175 25 175 2850   65  150supra 20   49.7     143  
150QJ25-200 200 30 66.6      
150QJ25-290 290 37 82.1      
150QJ32-120 32 120 2850   80  150supra 20 380 49.7     143  
150QJ32-132 132 25 56.5      
150QJ32-156 156 30 66.6      
150QJ32-190 190 37 82.1      
150QJ32-240 240 45 96.9      
150QJ40-110 40 110 2850   80  150supra 20 380 49.7     143  
150QJ40-121 121 25 56.5      
150QJ40-143 143 30 66.6      
150QJ40-176 176 37 82.1      
150QJ40-220 220 45 96.9      
150QJ50-100 50 100 2850   80  150supra 20 380 49.7     143  
150QJ50-110 110 25 56.5      
150QJ50-130 130 30 66.6      
150QJ50-160 160 37 82.1      
150QJ50-200 200 45 96.9      

 

 
Salus Cautelae

 The well submersible pump is a kind of pump suitable for clean water. It is strictly prohibited to dig new wells and extract sediment and turbid water. The voltage grade of the pump is 380/50HZ, and other submersible motors with different voltage grades need to be customized. Underground cables must be waterproof and must be equipped with starting equipment, such as distribution box, etc. The starting equipment should have conventional comprehensive motor protection functions, such as short circuit overload protection, phase loss protection, undervoltage protection, grounding protection and no-load protection. In abnormal cases, the protection device should be tripped in time. During installation and use, it is necessary to ensure that the pump is reliably grounded. It is forbidden to push and pull the switch when hands and feet are wet. The power supply must be cut off before installation and maintenance of the pump. In the place where the pump is used, an obvious "anti-electric shock" sign must be set up. Before going down the well or installing the motor, the internal chamber must be filled with distilled water or non-corrosive clean cold water. The water adding/discharge bolt must be tightened. When testing the pump on the ground, water must be poured into the pump chamber to lubricate the rubber bearings. The instant start should not exceed one second to check whether the direction is correct, the same as the steering indication. Pay attention to safety when the pump is upright to prevent overturning and injury. Strictly in accordance with the provisions of the pump lift and flow range of use, to prevent the pump in low lift has a large flow or in high lift has a large pull, resulting in extreme wear of thrust bearings and other components, resulting in motor overload burnout. After the pump into the well, the insulation resistance of the motor and the ground shall be measured, which shall not be less than 100MΩ. After the start, observe the voltage and current regularly, and check whether the motor winding insulation meets the requirements; if the temperature of the pump storage location is below the freezing point, the water in the motor cavity shall be discharged to prevent freezing damage to the motor.

 

 
Introductio ad Structuram

Brevis introductio structurae: pars sentinae maxime componitur ex stipite sentinali, impulsore, putamine diversio, globulus portante, valvae corporis (partes ad libitum) et alia membra inspicienda. Pars motor maxime composita ex basi, pressione cinematographico moderante, bracteae impulsus portans, fixurae laminae, dux inferior sedem gerens, stator, rotor, dux superior sedem gerens, annulum harenae, aqua limbum sectio, funem et alia elementa.


Pelagus features productum includit:

 I, motor aquaticus plenus humidus submersibilis asynchronous motor tres phase asynchronous motor est, cavitatis motoriae plena est aqua munda, ad refrigerandum motorem et praeligatum ferentem, pressionis cinematographicae in fundo motoris moderatae aptando. ex expansione et contractione pressionis differentiae aquae intra corpus causatum ex mutatione caliditatis oriuntur motoris.

 2, Ut arena in puteo aquae motoris ne ingrediatur, superior finis motoris scapus duobus sigillis olei instructus est, et anulus arenarius instituitur ad structuram arcendam ne structuram formandam.

 3, Ad ne scapi sentinam excurrere incipiendo, scapi sentinae et scapus motoriis coitu inter se conexi sunt, superiorque impulsus in inferiore parte motoris instituitur.

 IV, lubricatio motoris et sentinae afferentis est aqua lubricatio.

 5, Motor stator coluber factus est altae qualitatis filum flexuosum submersibile, cum magna operatione velit.

 VI, Sentina ab computatrum CAD designatur, cum simplici structura et operatione technica bona.

150QJR Deep Well Submersible Pump
 
install

 

(I) Praeparatio ante institutionem:
1. Perspice an sentinam submersibilem usui conditionibus occurrat et ambitum in manuali definitum.
2. Utens obiectu gravi cum diametro aequali maximo diametro exterioris sentinae submersibilis, metire an inneldiametri putoris sentinam submersibilem aptare possit, et metire an puteus profundus ad institutionem requisita occurrat.
3. Reprehendo utrum puteus mundus sit, et si puteus aqua turbidus est. Numquam uti sentinam electricam submersibilem ad lavandum putorem sentinam lutum et aquam arenam ad vitandum praematurum damnum ad sentinam electricam submersibilem.
4. Reprehendo an positio fibulae institutionis welhead sit conveniens et an qualitatem totius unitatis sustinere possit
5. Reprehendo si partes sentinae submersibiles sint perfectae et rite institutae secundum schematis conventus in manu-Removeo velum colum et gyrari queat ad videndum an mollius circumagatur.
6. Aquam cochleae et cavum mobilem reple, non mordax aqua (ex corrosivis (vide ut eam sursum), tum obstringas aqualram. Post 12 horas aquae injectiones, insulatio motoris resistentia non minus quam 150M Q mensurata est cum 500V tabula quatiens.
7. Cable joint, cut off a 120mm rubber sleeve from one end of the outgoing cable and the matching cable with an electrician's knifethen stagger the length of the three core wires in a stepped shape, peel off a 20mm copper core, scrape of the oxide layer on theoutside of the copper wire with a knife or sand cloth, and insert the two connected wire ends in palirs.After tying the layer tightly with fine copper wire, solder it thoroughly and firmly, and sand of any. burrs on the surface. Then, forthe three joints, use polyvester insulation tape to wrap them in a semi stacked manner for three lavers. Wrap the two ends of thewrapping layer tightywith nyion thread,and then use a semi stacked method to wrap the tape for three layers. Wrap the outellayer with high-pressure insulation tape for three layers. Finally, fold the threestrands together and repeatedly wrap them for fivelayers with high-pressure tape. Each layer must be tightly tied, and the interlayer joints must be tight and fimm to prevent water frompenetrating and damaging the insulation, After wrapping, soak in water at room temperature of 20 ’c for 12 hours, and measurethe insulation resistance with a shaking table, which should not be less than 100M Ω

 

Adnexa funis processus schematis wiring talis est:
150QJR Deep Well Submersible Pump

 

8. Multimetro utere ad reprimendam num tria-phasma fila connexa sint et an resistentia DC proxime libratum sit.
9. Perscriptio num ambitus et transformantis capacitas cumulatur, et tunc coniunge cum onere transitum tutelae vel apparatum incipiens. Vide Tabulam 2 ad exempla specifica, et mitte situlam aquae in sentinam aquae ex aqua sentinae exitum ad praestringendum iuvantis gestus in sentinam, et pone sentinam submersibilem electricam erectam et constantem.Start (non plus quam unum secundum) et vide utrum directio gubernii sit cum signo gubernaculo consonans. Sin minus, aliquos duos connexiones trium-phase cables permuto. Deinde colum inaugurare et ad puteum descendere parant. Si in peculiaribus occasionibus adhibeantur (sicut fossae, fossae, flumina, stagna, stagna, etc.), sentinam electricam certo fundari debent.

 

(2) Installation instrumentorum et instrumentorum;
1. Unum par catenarum levandi plus duobus talentis.
2. Tripode cum perpendiculo non minus quam quattuor metra.
3. Duo funes suspensi (funes filum) qui pondus plus quam unum ton ferre possunt (pondere aquae soleatus completae).
4. duo paria fibulatorum inaugurare (facile).
5. Clavis, malleis, verticillis, instrumentis electricis et instrumentis, etc.

 

(III) Electric sentinam institutionem:
1. Tabulae institutionis sentinae submersibilis electrici in Figura ostenditur 2. Specificae institutiones dimensiones in Tabula 3 monstrantur "Index institutionis Dimensiones Submersible Electric Pump".

 

2. Solatus electrici submersibiles cum capite minore quam 30 metra directe levari possunt in puteum caligarum et funiculos filum vel alias funiculos cannabinos, qui plenum pondus totius machinae, fistulae aquae et aquae in tibiis ferre possunt.

 

3. Pumps cum capite plusquam 30 metrorum utimur fistulis ferreis, et series institutionis haec est:
① Fibulae utere ad fibulae partem superiorem sentinam aquae (motricis et aquae sentinae hoc tempore coniunctae sunt), eam cum cathena pensili tolle, et lente eam in puteum ligabis, donec Fibulae in putei caput auferas et removeas. catena pendula.
② Alterum par fibularum utere ad fistulam fibulae, eam leva cum cathena pendula 15 cm a LABIUM, et lente deprime. Inter fistulam LABIUM et sentinam flangePut Flexilis caudex in loco, et obstringere tibiam et sentinam aequabiliter cum valvis, nucibus et lavatoribus veris.
③ Sentinam submersibilem leviter tolle, fibulam in superiore fine aquae sentinae tolle, funem ligabis ad fistulam aquae cum taenia plastica firmiter, et lente ligabis eam donec Fibulae ad putei caput ponatur.
Eadem methodo omnes aquae fistulas in puteum alligant.
⑤Post funem plumbeum ad imperium transitum coniungitur, cum copia trium phase iungitur.


(4.) Notae in installation:
1. Si vallum phaenomenon in flantibus processum inveniatur, vertere vel fistulam aquam trahere, ut punctum vallum superetur. Si variae mensurae adhuc non operantur, quaeso Noli sentinam cogere ad vitandum damnum in sentinam electricam et puteum submersibilem.
2. In institutione, codex iuvantis ad cuiusque fistulae LABIUM collocari debet et aequaliter coarctari.
3. Cum aqua sentina in puteum demissa, in media fistula putei poni debet, ne sentinam contra murum putei diu curreret, sentinam pulsum et motorem verrere et comburere. .
4. Determinare profunditatem aquae sentinae ad imum putei iuxta arenam fluentem et condiciones putei limum. Sentinam in luto non sepelias. Distantia aquae sentinae ad fundum putei fere non minus quam 3 metra (vide figura 2).
5. Aquae viscus profunditas aquae sentinae non minus esse debet quam 1-1.5 metra a gradu aquae dynamicae ad nodi aquae diverticulum (vide Figure 2). Alioquin aquae sentinae gestus facile laedantur.
6. Aquae levare sentinam nimis humilis esse non potest. Alioquin valvae portae aquae putei fistulae inaugurari debet ut fluere sentinam fluere apud punctum aestimatum fluere prohibeat ne motor oneretur et exuratur propter magnas rates fluxus.
7. Cum aqua currit sentina, aqua output continuum et par esse debet, currens sit stabilis (sub condiciones operationis aestimatae, plerumque non plus quam 10% currentis aestimatae), nec vibratio nec strepitus esse debet. Si qua deprauatio est, machina cessari debet causam cognoscendi et removendi.
8. Cum inaugurari, attende ad occasum filum fundationis motoris (vide Figure 2). Fistula cum aqua est ferrea tibia, a puteo fibulato duc; cum fistula aquatica fistula plastica est, eam a fundamento sentinae electrici notam duc.

 

 
Tutela et sustentationem
  • 1. Post sentinam submersibilem inauguratur, velit resistentia et tres phases conductionis ex switch iterum retentare, inspicias num instrumentum et nexum instrumentorum initii fallant, si dubium non est, machina temptatio inchoari potest; et vide an lectiones instrumenti indicativi excedant intentionem aestimatam et currentem in nominato post initium determinatam, et vide an sentinam habeat phaenomenon strepitum et vibrationem, et in operando si omnia normalia sunt.
  • 2. Post primam sentinam operationem per quattuor horas, motor occlusus debet esse ad resistentiam scelerisque velitandi explorandam cito, eiusque valor non minus quam 0.5 megaohm esse debet.
  • 3. Post occlusam sentinam, incepit post quinque minutas ne columna aqua in tibia omnino refluxit et causans excessus motoris et burnout.
  • 4. Post sentinam in operationem normalem ponatur, ut vitam suam proroget, necesse est ut inspicias an copia intentionum, currentium et velitium resistentiae normales regulariter sint. Si sequentes condiciones inveniantur, antliae statim ad troubleshoot claudenda.
  •  
  • - In conditione aestimata, hodierna 20% excedit.
  • — Aquae dynamicae in gradu aquae guttae ad sectio limbi aquae causando aquam intermissam.
  • - Sentinam submersibilem habet gravem vibrationem vel strepitum.
  • — Copia intentionis infra 340 voltas est.
  • — A fuse exuritur.
  • — Aquarum fistula laeditur.
  • - Nulla resistentia scelerisque motoris minor est quam 0,5 megaohm.
  •  
  • 5.Unit disassembly:
  • - Solve funem ligamen, partem fistulam remove, et laminam filum remove.
  • - Descende aquam fulmine cochleae, pone aquam in camera motoria.
  • - colum remove, solve cochleam fixam in junctura, figere vecte motoriam.
  • - Cochlee descendit fulmen cum sectione motore aquam connectens limbum, et sentinam a motore separa (attende ad pulvinum unitatis cum secernendo, ne flexo scapi sentinae)
  • - Disassembly series sentinae est: (vide figuram 1) sectio limbi aquae, impulsor, divortium, concha, impulsor ....... corpus valvae reprehendo, cum impulsor removens, specialia instrumenta adhibent ut manicam conicam fixarum laxent. impulsor prius, et ne inflectens et sentinam stipitem in processu disassemble contundere.
  • - Disassembly processus motoris est: (vide figure 1) motorem in suggestu ponere, et nuces basi tollere, hastile nucis caput densis, laminam clavum impellere, clavem, inferiorem ducem sedentem ferens et duplex caput fulmen ab imo. in vicem motoris, et deinde rotor (animadverte ne sarcinam filum laedas) tollas et demum sectionem connectentem et ductorem superiorem sedem gestantem removeas.
  • - Unitas conventus: ante conventum, aerugo et sordes partium purgari debent, et superficies coitus et fasteners obductis cum sealant, et tunc in opposito ordine disassemble congregantur (scapus motor movens sursum et deorsum post conventum circiter unum. millimetre), post conventum, coniunctio flexibilis esse debet, et postea machina emissarium velamentum test. Soleatus submersibiles accipientur e puteo ad distrahendum et sustentandum secundum Articulum 5 post annum operationis, vel minus quam annus operationis, sed biennium tempus tribuendi, et partes attritae reponentur.

 

 
Repono et custodiam

 Welcome to use our submersible pump products!Our products are exquisitely designed and convenient to use, widely used in family, agriculture, and industrial fields.In order to ensure the lasting and stable performance of your products, we suggest paying special attention to drainage in winter to prevent motor icing, and rolling and tying the cable tightly.When storing, please choose an environment without corrosive substances and harmful gases, and keep the temperature below 40 °C.If you do not use it for a long time, please pay attention to rust prevention to protect the quality of the submersible pump.Wish you a smooth and unimpeded use experience, thank you for choosing our products!

 

 
Partibus gerens
  • Impeller
  • hastile sleeve
  • Flexilis scapus sleeve
  • signantes anulum

 
Application missiones

I Aquam profunda bene attractio

II High-surgere aquarum copia

03 mons aquae copia 

04 aqua turris

05 Irrigatio agriculturae

VI hortus irrigationis

07 attractio aquae fluminis

08 aqua domestica

 

 

Si interest in productis nostris, informationes tuas hic relinquere potes, et tecum brevi tactus erimus.


Epistulam tuam hic scribe et mitte nobis

Si interest in productis nostris, informationes tuas hic relinquere potes, et tecum brevi tactus erimus.


laLatin