200QJP Peep Well-Tauchpumpe

OEM-Verarbeitung durchführen! Entsprechend den Benutzeranforderungen werden verschiedene Arten von Sonderanforderungen für nicht standardmäßige Tauchmotoren und -pumpen entworfen und hergestellt. Die Produktimplementierungsstandards: GB/T2816-2014 „Brunnen-Tauchpumpe“, GB/T2818-2014 „Brunnen-Tauch-Asynchronmotor“. WhatsApp: 17855846335
PDF DOWNLOAD
Einzelheiten
Stichworte
 
Produktübersicht

QJP series special fountain pump is a special fountain pump developed by our factory. The pump motor core is made of high quality cold rolled silicon steel, which makes the pump more efficient, has good magnetic conductivity, and does not produce heat when starting frequently. The two ends of the motor rotor are covered with alloy copper sleeve as lubricant, using water. Stainless steel sleeves replace ball bearings, avoiding the problem of easy rust of ball bearings and the problem of motor burning due to lack of oil wear. It is very suitable for music fountain, all models can be used horizontally.

 

 
Nutzungsbedingungen

This product uses three-phase AC 380V power supply (tolerance + 5%), 50HZ frequency (tolerance + 1%); the applicable water quality conditions for water temperature is not higher than 20 °C, solid impurities content (mass ratio) is not more than 0.01%, pH value (pH) is 6.5-8.5, hydrogen sulfide content is not more than 1.5mg/L, chloride ion content is not more than 400mg/L. The motor adopts closed or water sealed wet structure, before use must be filled with clean water to prevent virtual filled, and then tighten the water injection and air exhaust bolts, otherwise not to use. Submersible pump must be completely immersed in water to work, immersion depth shall not exceed 70 meters, the distance between the bottom of the submersible pump and the bottom of the well shall not be less than 3 meters. The water in the well should be able to meet the water output and continuous operation of the submersible pump, the water output of the pump should be controlled at 0.7-1.2 times the rated flow. The well should be kept vertical, the submersible pump can not be used horizontally or overturned, only vertical installation. The submersible pump must be equipped with cables as required, and equipped with external overload protection device. The pump is strictly prohibited from no water load test.

 

 
Modell Bedeutung

200QJP Peep Well Submersible Pump

 

 
Teilmodellreferenz
Modell Durchfluss (m3/h) Kopf
(M)

Drehgeschwindigkeit

(Wechselpunkt)

Wasserpumpe(%)  Auslauf
Durchmesser
(mm)
Gut anwendbar
Durchmesser (mm) 
 Bewertet
power(KW)
Bewertet
Spannung (V)
Bewertet
Strom (A)
Motoreffizienz (%) power factorcosφ   Einheit
Radiale Maximalgröße (mm)
Anmerkung
200QJ20-40 20 40 2850 66 50  200über 4 380 10.1 76.0 0.79 184  
200QJ20-54 54 5.5 13.6 77.0 0.8  
200QJ20-81 81 7.5 18.0 78.0 0.81  
200QJ20-93 93 9.2 21.7 78.5 0.82  
200QJ20-108 108 11 25.8 79.0 0.82  
200QJ20-121 121 13 29.8 80.0 0.83  
200QJ20-148 148 15 33.9 81.0 0.83  
200QJ20-175 175 18.5 41.6 81.5 0.83  
200QJ20-202 202 22 48.2 82.5 0.84  
200QJ20-243 243 25 54.5 83.0 0.84  
200QJ20-270 270 30 65.4 83.0 0.84  
200QJ20-360 360 37 79.7 84.0 0.84  
200QJ20-442 442 45 96.9 84.0 0.84  
200QJ25-28 25 28 2850 68 65  200über 4 380 10.1 76.0 0.79 184  
200QJ25-42 42 5.5 13.6 77.0 0.8  
200QJ25-56 56 7.5 18.0 78.0 0.81  
200QJ25-70 70 9.2 21.7 78.5 0.82  
200QJ25-98 98 11 25.8 79.0 0.82  
200QJ25-112 25 112 2850 68 65  200über 13 380 29.8 80.0 0.83 184  
200QJ25-126 126 15 33.9 81.0 0.83  
200QJ25-154 154 18.5 41.6 81.5 0.83  
200QJ25-182 182 22 48.2 82.5 0.84  
200QJ25-210 210 25 54.5 83.0 0.84  
200QJ25-252 252 30 65.4 83.0 0.84  
200QJ25-308 308 37 79.7 84.0 0.84  
200QJ25-378 378 45 96.9 84.0 0.84  
200QJ32-26 32 26 2850 70 80  200über 4 380 10.1 76.0 0.79 184  
200QJ32-39 39 5.5 13.6 77.0 0.8  
200QJ32-52 52 7.5 18.0 78.0 0.81  
200QJ32-65 65 9.2 21.7 78.5 0.82  
200QJ32-78 78 11 25.8 79.0 0.82  
200QJ32-91 91 13 29.8 80.0 0.83  
200QJ32-104 104 15 33.9 81.0 0.83  
200QJ32-130 130 18.5 41.6 81.5 0.83  
200QJ32-143 143 22 48.2 82.5 0.84  
200QJ32-169 169 25 54.5 83.0 0.84  
200QJ32-195 195 30 65.4 83.0 0.84  
200QJ32-247 247 37 79.7 84.0 0.84  
200QJ32-299 299 45 96.9 84.0 0.84  
200QJ40-26 40 26 2850 72 80  200über 5.5 380 13.6 77.0 0.8 184  
200QJ40-39 39 7.5 18.0 78.0 0.81  
200QJ40-52 52 9.2 21.7 78.5 0.82  
200QJ40-65 65 11 25.8 79.0 0.82  
200QJ40-78 78 15 33.9 81.0 0.83  
200QJ40-104 104 18.5 41.6 81.5 0.83  
200QJ40-117 117 22 48.2 82.5 0.84  
200QJ40-143 143 25 54.5 83.0 0.84  
200QJ40-169 169 30 65.4 83.0 0.84  
200QJ40-208 208 37 79.7 84.0 0.84  
200QJ40-247 247 45 96.9 84.0 0.84  
200QJ50-26 50 26 2850 74 80  200über 5.5 380 13.6 77.0 0.8 184  
200QJ50-39 39 9.2 21.7 78.5 0.82  
200QJ50-52 52 11 25.8 79.0 0.82  
200QJ50-65 65 15 33.9 81.0 0.83  
200QJ50-78 78 18.5 41.6 81.5 0.83  
200QJ50-91 91 22 48.2 82.5 0.84  
200QJ50-104 104 25 54.5 83.0 0.84  
200QJ50-130 130 30 65.4 83.0 0.84  
200QJ50-156 156 37 79.7 84.0 0.84  
200QJ50-208 208 45 96.9 84.0 0.84  
200QJ63-24 63 24 2850 74 80  200über 7.5 380 18.0 78.0 0.81 184  
200QJ63-36 36 11 25.8 79.0 0.82  
200QJ63-60 60 18.5 41.6 81.5 0.83  
200QJ63-72 72 22 48.2 82.5 0.84  
200QJ63-84 84 25 54.5 83.0 0.84  
200QJ63-96 96 30 65.4 83.0 0.84  
200QJ63-120 120 37 79.7 84.0 0.84  
200QJ63-144 144 45 96.9 84.0 0.84  
200QJ80-22 80 22 2850 75 100  200über 7.5 380 18.0 78.0 0.81 184  
200QJ80-33 33 11 25.8 79.0 0.82  
200QJ80-44 44 15 33.9 81.0 0.83  
200QJ80-55 55 18.5 41.6 81.5 0.83  
200QJ80-66 66 22 48.2 82.5 0.84  
200QJ80-88 88 30 65.4 83.0 0.84  
200QJ80-99 99 37 79.7 84.0 0.84  
200QJ80-121 121 45 96.9 84.0 0.84  
200QJ100-18 100 18 2850 75 100  200über 9.2 380 21.7 78.5 0.82 184  
200QJ100-27 27 13 29.8 80.0 0.83  
200QJ100-36 36 18.5 41.6 81.5 0.83  
200QJ100-45 45 22 48.2 82.5 0.84  
200QJ100-54 54 25 54.5 83.0 0.84  
200QJ100-63 63 30 65.4 83.0 0.84  
200QJ100-72 100 72 2850 75 100  200über 37 380 79.7 84.0 0.84 184  
200QJ100-90 90 45 96.9 84.0 0.84  

 

 
Sicherheitsvorkehrungen

 Well submersible pump is a kind of fresh water pump, it is strictly prohibited to dig new wells and pump mud and sand. The product adopts 380/50HZ voltage grade, other voltage grades shall not be used, and the submersible motor needs to be customized. Underground cables must use waterproof cables, and must be equipped with starting equipment, such as distribution box, etc. The starting equipment shall have common motor comprehensive protection functions, such as short circuit overload protection, phase loss protection, undervoltage protection, grounding protection and no-load protection, etc. In abnormal cases, the protection device shall be tripped in time. When installed and used, the pump must be reliably grounded, it is prohibited to push and pull the switch when hands and feet are wet, and the power supply must be cut off before installation and maintenance of the pump. In the place where the pump is used, an obvious "anti-electric shock" sign must be set up. Before going down the well or installing, the motor must be filled with distilled water or non-corrosive clean cold water, and the water adding/discharge bolts must be tightened. When testing the pump on the ground, water must be injected into the pump chamber to lubricate the rubber bearings. The instantaneous start time shall not exceed one second to check whether the steering is correct, pay attention to safety, and prevent the pump from toppling and injuring people when it is upright. In strict accordance with the specified lift and flow range of the pump, to prevent the pump in low lift with large flow or in high lift with large traction, resulting in extreme wear of thrust bearings and other components, the motor overload and burn. After the pump into the well, the motor to the ground insulation resistance should be measured not less than 100MΩ. After the start, regular observation of voltage and current, and check whether the motor winding insulation meets the requirements; if the location of the pump storage temperature below freezing, should discharge the water in the motor cavity, to prevent water in the motor cavity ice and damage the motor due to low temperature.

 

 
Einführung in die Struktur

Kurze Einführung in die Struktur: Der Pumpenteil besteht hauptsächlich aus Pumpenwelle, Laufrad, Umleitungsgehäuse, Gummilager, Rückschlagventilkörper (optionale Teile) und anderen Komponenten. Der Motorteil besteht hauptsächlich aus Basis, Druckregulierungsfolie, Axiallager, Axialplatte, unterem Führungslagersitz, Stator, Rotor, oberem Führungslagersitz, Sandring, Wassereinlassabschnitt, Kabel und anderen Komponenten.



Zu den Hauptmerkmalen des Produkts gehören:

 1. Der Motor ist ein wassergefüllter, nasser, tauchfähiger Dreiphasen-Asynchronmotor. Der Motorraum ist mit sauberem Wasser gefüllt, das zur Kühlung des Motors und zur Schmierung des Lagers verwendet wird. Der druckregulierende Film an der Unterseite des Motors wird verwendet, um die Ausdehnungs- und Kontraktionsdruckdifferenz des Wassers im Körper auszugleichen, die durch die Änderung des Temperaturanstiegs des Motors verursacht wird.

 2. Um zu verhindern, dass Sand aus dem Brunnenwasser in den Motor eindringt, ist das obere Ende der Motorwelle mit zwei Öldichtungen ausgestattet und ein Sandring ist installiert, um eine Sandschutzstruktur zu bilden.

 3. Um ein Hochlaufen der Pumpenwelle beim Starten zu verhindern, sind die Pumpenwelle und die Motorwelle durch eine Kupplung verbunden und am unteren Teil des Motors ist ein oberes Axiallager eingebaut.

 4. Die Schmierung des Motors und der Pumpenlager erfolgt mittels Wasserschmierung.

 5. Die Statorwicklung des Motors besteht aus hochwertigem Wickeldraht für Tauchmotoren mit hoher Isolationsleistung.

 6. Die Pumpe wurde per Computer-CAD entworfen und hat eine einfache Struktur und gute technische Leistung.

200QJP Peep Well Submersible Pump
 
Installieren

(1)Vorbereitung vor der Installation:
1. Prüfen Sie, ob die Tauchpumpe die in der Anleitung angegebenen Einsatzbedingungen und den Einsatzbereich erfüllt.
2. Messen Sie mit einem schweren Gegenstand, dessen Durchmesser dem maximalen Außendurchmesser der Tauchpumpe entspricht, ob der Innendurchmesser des Bohrlochs für die Tauchpumpe geeignet ist, und messen Sie, ob die Bohrlochtiefe den Installationsanforderungen entspricht.
3. Überprüfen Sie, ob das Bohrloch sauber ist und ob das Brunnenwasser trübe ist. Verwenden Sie niemals eine Tauchpumpe, um Schlamm und Sandwasser aus der Brunnenpumpe zu waschen, um vorzeitige Schäden an der Tauchpumpe zu vermeiden.
4. Prüfen Sie, ob die Position der Schweißkopf-Montageklemme geeignet ist und ob sie der Qualität der gesamten Einheit standhält
5. Überprüfen Sie, ob die Komponenten der Tauchpumpe vollständig sind und gemäß dem Montageplan im Handbuch ordnungsgemäß installiert wurden. Entfernen Sie das Filtersieb und drehen Sie die Kupplung, um zu sehen, ob sie sich flexibel dreht.
6. Die Wasserschraube abschrauben und den Motorhohlraum mit sauberem, nicht korrosivem Wasser füllen (Hinweis: unbedingt auffüllen), dann die Wasserschraube festziehen. Nach 12 Stunden Wassereinspritzung sollte der Isolationswiderstand des Motors bei Messung mit einem 500-V-Schütteltisch nicht weniger als 150 MQ betragen.
7. Cable joint, cut off a 120mm rubber sleeve from one end of the outgoing cable and the matching cable with an electrician's knifethen stagger the length of the three core wires in a stepped shape, peel off a 20mm copper core, scrape of the oxide layer on theoutside of the copper wire with a knife or sand cloth, and insert the two connected wire ends in palirs.After tying the layer tightly with fine copper wire, solder it thoroughly and firmly, and sand of any. burrs on the surface. Then, forthe three joints, use polyvester insulation tape to wrap them in a semi stacked manner for three lavers. Wrap the two ends of thewrapping layer tightywith nyion thread,and then use a semi stacked method to wrap the tape for three layers. Wrap the outellayer with high-pressure insulation tape for three layers. Finally, fold the threestrands together and repeatedly wrap them for fivelayers with high-pressure tape. Each layer must be tightly tied, and the interlayer joints must be tight and fimm to prevent water frompenetrating and damaging the insulation, After wrapping, soak in water at room temperature of 20 ’c for 12 hours, and measurethe insulation resistance with a shaking table, which should not be less than 100M Ω

 

Das beigefügte Diagramm zur Kabelverlegung sieht wie folgt aus:

200QJP Peep Well Submersible Pump

 

8. Prüfen Sie mit einem Multimeter, ob die Drehstromleitungen angeschlossen sind und der Gleichstromwiderstand etwa ausgeglichen ist.
9. Überprüfen Sie, ob der Stromkreis und die Transformatorkapazität überlastet sind, und schließen Sie dann den Überlastschutzschalter oder die Startvorrichtung an. Siehe Tabelle 2 für bestimmte Modelle. Gießen Sie dann einen Eimer Wasser aus dem Wasserpumpenauslass in die Wasserpumpe, um die Gummilager in der Pumpe zu schmieren, und stellen Sie die Tauchpumpe dann aufrecht und stabil auf. Starten Sie (nicht länger als eine Sekunde) und prüfen Sie, ob die Lenkrichtung mit dem Lenkzeichen übereinstimmt. Wenn nicht, tauschen Sie zwei beliebige Anschlüsse des Dreiphasenkabels aus. Installieren Sie dann den Filter und bereiten Sie sich darauf vor, in den Brunnen zu gehen. Bei Verwendung in besonderen Fällen (z. B. Gräben, Flüssen, Teichen, Teichen usw.) muss die Elektropumpe zuverlässig geerdet sein.

 

(2)Installationsausrüstung und Werkzeuge:
1. Ein Paar Hebeketten für mehr als zwei Tonnen.
2. Ein Stativ mit einer vertikalen Höhe von mindestens vier Metern.
3. Zwei Hängeseile (Drahtseile), die ein Gewicht von mehr als einer Tonne tragen können (können das Gewicht eines kompletten Wasserpumpensatzes tragen).
4. Installieren Sie zwei Paar Klammern (Schienen).
5. Schraubenschlüssel, Hämmer, Schraubendreher, elektrische Werkzeuge und Instrumente usw.

 

(3)Installation der elektrischen Pumpe:
1. Das Installationsdiagramm der Tauchelektropumpe ist in Abbildung 2 dargestellt. Die spezifischen Installationsabmessungen sind in Tabelle 3 „Liste der Installationsabmessungen der Tauchelektropumpe“ aufgeführt.

 

2. Tauchpumpen mit einer Förderhöhe von weniger als 30 Metern können mit Schläuchen und Drahtseilen oder anderen Hanfseilen, die das gesamte Gewicht der gesamten Maschine, der Wasserleitungen und des Wassers in den Rohren tragen können, direkt in den Brunnen gehoben werden.

 

3. Pumpen mit einer Förderhöhe von mehr als 30 Metern verwenden Stahlrohre und die Installationsreihenfolge ist wie folgt:
①Befestigen Sie das obere Ende des Wasserpumpenteils mit einer Klemme (Motor und Wasserpumpe sind zu diesem Zeitpunkt bereits verbunden), heben Sie es mit einer Hängekette an und binden Sie es langsam in den Brunnen, bis die Klemme auf den Brunnenkopf aufgesetzt und die Hängekette entfernt ist.
② Verwenden Sie ein weiteres Paar Klemmen, um ein Rohr festzuklemmen, heben Sie es mit einer Hängekette 15 cm vom Flansch entfernt an und senken Sie es langsam ab. Legen Sie zwischen Rohrflansch und Pumpenflansch das Gummipolster an und ziehen Sie Rohr und Pumpe mit Schrauben, Muttern und Federscheiben gleichmäßig fest.
③ Heben Sie die Tauchpumpe leicht an, entfernen Sie die Klemme am oberen Ende der Wasserpumpe, binden Sie das Kabel mit einem Kunststoffband fest an die Wasserleitung und binden Sie es langsam nach unten, bis die Klemme am Bohrlochkopf platziert ist.
④Verwenden Sie die gleiche Methode, um alle Wasserleitungen an den Brunnen anzuschließen.
⑤Nachdem das Ausgangskabel mit dem Steuerschalter verbunden ist, wird es an die dreiphasige Stromversorgung angeschlossen.


(4)Bei der Installation zu beachtende Punkte:
1. Wenn während des Pumpvorgangs ein Blockierungsphänomen festgestellt wird, drehen oder ziehen Sie am Wasserrohr, um die Blockierungsstelle zu beheben. Wenn verschiedene Maßnahmen immer noch nicht funktionieren, drücken Sie die Pumpe bitte nicht mit Gewalt nach unten, um Schäden an der Tauchpumpe und dem Brunnen zu vermeiden.
2. Während der Installation sollte am Flansch jedes Rohrs eine Gummiunterlage platziert und gleichmäßig festgezogen werden.
3. Wenn die Wasserpumpe in den Brunnen abgesenkt wird, sollte sie in der Mitte des Brunnenrohrs platziert werden, um zu verhindern, dass die Pumpe längere Zeit gegen die Brunnenwand läuft, was zu Vibrationen der Pumpe und zum Fegen und Verbrennen des Motors führen kann.
4. Bestimmen Sie die Tiefe der Wasserpumpe bis zum Boden des Brunnens entsprechend den fließenden Sand- und Schlickbedingungen des Brunnens. Vergraben Sie die Pumpe nicht im Schlamm. Der Abstand von der Wasserpumpe bis zum Boden des Brunnens beträgt im Allgemeinen nicht weniger als 3 Meter (siehe Abbildung 2).
5. Die Wassereintrittstiefe der Wasserpumpe sollte vom dynamischen Wasserstand bis zum Wassereinlassknoten nicht weniger als 1–1,5 Meter betragen (siehe Abbildung 2). Andernfalls können die Lager der Wasserpumpe leicht beschädigt werden.
6. Die Förderhöhe der Wasserpumpe darf nicht zu niedrig sein. Andernfalls muss an der Wasserleitung am Bohrlochkopf ein Absperrschieber installiert werden, um den Pumpendurchfluss am Nenndurchflusspunkt zu steuern und zu verhindern, dass der Motor aufgrund großer Durchflussraten überlastet wird und durchbrennt.
7. Wenn die Wasserpumpe läuft, sollte die Wasserabgabe kontinuierlich und gleichmäßig erfolgen, der Strom sollte stabil sein (unter Nennbetriebsbedingungen im Allgemeinen nicht mehr als 10 % des Nennstroms) und es sollten keine Vibrationen oder Geräusche auftreten. Bei Anomalien sollte die Maschine angehalten werden, um die Ursache herauszufinden und zu beseitigen.
8. Achten Sie bei der Installation auf die Einstellung des Motorerdungskabels (siehe Abbildung 2). Wenn es sich bei der Wasserleitung um ein Stahlrohr handelt, führen Sie es von der Bohrlochkopfklemme aus; wenn es sich bei der Wasserleitung um ein Kunststoffrohr handelt, führen Sie es von der Erdungsmarkierung der Elektropumpe aus.

 

 
Wartung und Instandhaltung
  • 1. Nachdem die Tauchpumpe installiert wurde, überprüfen Sie erneut den Isolationswiderstand und die Dreiphasenleitung vom Schalter aus. Prüfen Sie, ob das Instrument und der Anschluss der Startausrüstung falsch sind. Wenn kein Problem vorliegt, kann die Testmaschine gestartet werden. Beobachten Sie, ob die Anzeigewerte des Instruments nach dem Start die auf dem Typenschild angegebene Nennspannung und -stromstärke überschreiten. Beobachten Sie, ob die Pumpe Geräusche oder Vibrationen aufweist. Wenn alles normal ist, nehmen Sie sie in Betrieb.
  • 2. Nach dem ersten Betrieb der Pumpe für vier Stunden sollte der Motor abgeschaltet werden, um den Wärmeisolationswiderstand schnell zu testen. Sein Wert sollte nicht weniger als 0,5 Megaohm betragen.
  • 3. Nachdem die Pumpe abgeschaltet wurde, sollte sie nach fünf Minuten wieder gestartet werden, um zu verhindern, dass die Wassersäule in der Leitung vollständig zurückfließt und es zu übermäßigem Motorstrom und Durchbrennen kommt.
  • 4.Nachdem die Pumpe in den Normalbetrieb genommen wurde, muss zur Verlängerung ihrer Lebensdauer regelmäßig überprüft werden, ob Versorgungsspannung, Betriebsstrom und Isolationswiderstand normal sind. Wenn die folgenden Bedingungen vorliegen, sollte die Pumpe zur Fehlerbehebung sofort abgeschaltet werden.
  •  
  • 1 In the rated condition, the current exceeds 20%.
  • 2 Der dynamische Wasserstand sinkt bis zum Wassereinlassbereich und verursacht intermittierendes Wasser.
  • 3 Die Tauchpumpe vibriert stark oder macht Geräusche.
  • 4 Die Versorgungsspannung ist niedriger als 340 Volt.
  • 5 Eine Sicherung ist durchgebrannt.
  • 6 Die Wasserzuleitung ist beschädigt.
  • 7 The motor's thermal insulation resistance is lower than 0.5 megaohm.
  •  
  • Unit disassembly:
  • 1.Untie the cable tie, remove the pipeline part, and remove the wire plate.
  • 2.screw down the water bolt, put the water in the motor chamber.
  • 3.remove the filter, loose the fixed screw on the coupling to fix the motor shaft.
  • 4.screw down the bolt connecting the water inlet section with the motor, and separate the pump from the motor (pay attention to the unit cushion when separating, to prevent the bending of the pump shaft)
  • 5.the disassembly sequence of the pump is: (see figure 1) water inlet section, impeller, diversion shell, impeller...... check valve body, when removing the impeller, use special tools to loosen the conical sleeve of the fixed impeller first, and avoid bending and bruising the pump shaft in the process of disassembly.
  • 6.the disassembly process of the motor is: (see figure 1) place the motor on the platform, and remove the nuts, base, shaft head locking nut, thrust plate, key, lower guide bearing seat and double head bolt from the bottom of the motor in turn, and then take out the rotor (pay attention not to damage the wire package) and finally remove the connecting section and upper guide bearing seat.
  • 7.unit assembly: before assembly, the rust and dirt of the parts should be cleaned, and the mating surface and fasteners coated with sealant, and then assembled in the opposite order of disassembly (the motor shaft moves up and down after assembly for about one millimeter), after assembly, the coupling should be flexible, and then the filter screen test machine. Submersible pumps shall be taken out of the well for dismantling and maintenance according to Article 5 after a year of operation, or less than a year of operation but two years of diving time, and the worn parts shall be replaced.

 

 
Lagerung und Verwahrung

 This product is a submersible pump, which is suitable for various water areas, such as home, agriculture and industry.In order to prevent the motor from freezing in winter, be sure to discharge all the water in the pump chamber, and roll and tie the cable well.In addition, a room without corrosive substances and gases and with a temperature below 40 °C should be selected for storage.When not in use for a long time, special attention should be paid to the rust prevention of the submersible pump.This product is exquisitely designed and convenient to use, which can help users efficiently deal with various water needs, and is an ideal choice for your home and industrial water.

 

 
Verschleißteile
  • Laufrad
  • Wellenschutzhülse
  • Wellenschutzhülse aus Gummi
  • Siegelring

 
Anwendungsszenarien

01 Wasserentnahme aus einem tiefen Brunnen

02 Hochwasserversorgung

03 Bergwasserversorgung

04 Turm Wasser

05 Landwirtschaftliche Bewässerung

06 Gartenbewässerung

07 Flusswasserentnahme

08 Brauchwasser

 

Wenn Sie an unseren Produkten interessiert sind, können Sie hier Ihre Informationen hinterlassen und wir werden uns in Kürze mit Ihnen in Verbindung setzen.


Schreiben Sie hier Ihre Nachricht und senden Sie diese an uns

Wenn Sie an unseren Produkten interessiert sind, können Sie hier Ihre Informationen hinterlassen und wir werden uns in Kürze mit Ihnen in Verbindung setzen.


de_DEGerman