Introducing the innovative QJP series fountain pump, a product of superior efficiency meticulously developed and researched by our factory. With a meticulously designed pump motor core crafted from premium cold rolled silicon steel, this fountain pump boasts exceptional magnetic conductivity, enabling seamless and heat-free starts. Unlike traditional fountain pumps, the 0JP series features motor rotor ends that utilize a unique water-lubricated alloy copper sleeve, replacing standard ball bearings. This innovative design not only mitigates issues of rust and wear caused by lack of oil but also ensures longevity and durability for the motor. Upgrade your fountain experience with the cutting-edge technology and superior performance of the QJP series fountain pump.
The product is a three-phase AC 380V (tolerance + / - 5%), 50HZ (tolerance + / - 1%) power supply, and has strict requirements for clean water: water temperature shall not exceed 20 °C; solid impurities content (mass ratio) shall not exceed 0.01%; PH value (pH) is 6.5-8.5; hydrogen sulfide content shall not exceed 1.5mg/L; chloride ion content shall not exceed 400mg/L. The product adopts a closed or water immersion structure motor, the submersible motor must be filled with clean water before use to prevent empty. In addition, the water can be used after filling and tightening the air release bolt. The submersible pump must be completely immersed in water to work, the diving depth shall not exceed 70m, and the distance between the bottom of the pump and the bottom of the well shall not be less than 3m. The well water flow should meet the water output and continuous operation requirements of the submersible pump, and the water output shall be controlled at 0.7-1.2 times of the rated flow. The well must be vertical, and the submersible pump can not be used horizontally, and it must be installed vertically. The submersible pump must match the cable as required and be equipped with external overload protection device. It is strictly prohibited to do no-load test without water.
Modèle | Débit (m3/h) | Tête (m) |
Vitesse de rotation (changement/point) |
Pompe à eau(%) | Sortie diamètre (mm) |
Bien applicable diamètre (mm) |
Noté puissance (KW) |
Noté tension (V) |
Noté courant (A) |
Efficacité moteur (%) | power factorcosφ | Unité Taille maximale radiale (mm) |
Remarque | |||||||||
135QJ5-34 | 5 | 34 | 2850 | 40 | 135au-dessus de | 1.5 | 380 | 4.23 | 128 | |||||||||||||
135QJ5-51 | 51 | 2.2 | 6.03 | |||||||||||||||||||
135QJ5-68 | 68 | 3 | 8.01 | |||||||||||||||||||
135QJ5-85 | 85 | 4 | 10.53 | |||||||||||||||||||
135QJ5-102 | 102 | 5.5 | 14.1 | |||||||||||||||||||
135QJ5-119 | 119 | 5.5 | 14.1 | |||||||||||||||||||
135QJ5-240 | 240 | 11 | 26.28 | |||||||||||||||||||
135QJ5-280 | 5 | 280 | 2850 | 40 | 135au-dessus de | 13 | 380 | 30.87 | 128 | |||||||||||||
135QJ5-320 | 320 | 15 | 35.62 | |||||||||||||||||||
135QJ10-24 | 10 | 24 | 2850 | 50 | 135au-dessus de | 1.5 | 380 | 4.23 | 128 | |||||||||||||
135QJ10-32 | 32 | 2.2 | 6.03 | |||||||||||||||||||
135QJ10-48 | 48 | 3 | 8.01 | |||||||||||||||||||
135QJ10-56 | 56 | 4 | 10.53 | |||||||||||||||||||
135QJ10-72 | 72 | 5.5 | 14.1 | |||||||||||||||||||
135QJ10-80 | 80 | 5.5 | 14.1 | |||||||||||||||||||
135QJ10-104 | 104 | 7.5 | 19.0 | |||||||||||||||||||
135QJ10-120 | 120 | 7.5 | 19.0 | |||||||||||||||||||
135QJ10-136 | 136 | 9.2 | 22.7 | |||||||||||||||||||
135QJ10-180 | 180 | 11 | 26.28 | |||||||||||||||||||
135QJ10-210 | 210 | 13 | 30.87 | |||||||||||||||||||
135QJ10-240 | 240 | 15 | 35.62 | |||||||||||||||||||
135QJ10-300 | 300 | 18.5 | 43.12 | |||||||||||||||||||
135QJ15-36 | 15 | 36 | 2850 | 50 | 135au-dessus de | 2.2 | 380 | 6.03 | 128 | |||||||||||||
135QJ15-39 | 39 | 3 | 8.01 | |||||||||||||||||||
135QJ15-46 | 46 | 4 | 10.53 | |||||||||||||||||||
135QJ15-52 | 52 | 4 | 10.53 | |||||||||||||||||||
135QJ15-59 | 59 | 5.5 | 14.1 | |||||||||||||||||||
135QJ15-65 | 65 | 5.5 | 14.1 | |||||||||||||||||||
135QJ15-78 | 78 | 7.5 | 19.0 | |||||||||||||||||||
135QJ15-91 | 91 | 7.5 | 19.0 | |||||||||||||||||||
135QJ15-104 | 104 | 9.2 | 22.7 | |||||||||||||||||||
135QJ15-120 | 120 | 11 | 26.28 | |||||||||||||||||||
135QJ15-142 | 142 | 13 | 30.87 | |||||||||||||||||||
135QJ15-162 | 162 | 15 | 35.62 | |||||||||||||||||||
135QJ15-200 | 200 | 18.5 | 43.12 | |||||||||||||||||||
135QJ20-16 | 20 | 16 | 2850 | 50 | 135above | 2.2 | 380 | 6.03 | 128 | |||||||||||||
135QJ20-24 | 24 | 3 | 8.01 | |||||||||||||||||||
135QJ20-32 | 32 | 4 | 10.53 | |||||||||||||||||||
135QJ20-40 | 40 | 4 | 10.53 | |||||||||||||||||||
135QJ20-48 | 48 | 5.5 | 14.1 | |||||||||||||||||||
135QJ20-56 | 56 | 5.5 | 14.1 | |||||||||||||||||||
135QJ20-64 | 64 | 7.5 | 19.0 | |||||||||||||||||||
135QJ20-72 | 72 | 7.5 | 19.0 | |||||||||||||||||||
135QJ20-80135QJ20-100 | 80 | 9.2 | 22.7 | |||||||||||||||||||
100 | 11 | 26.28 | ||||||||||||||||||||
135QJ20-120 | 120 | 13 | 30.87 | |||||||||||||||||||
135QJ20-136 | 136 | 15 | 35.62 | |||||||||||||||||||
135QJ20-168135QJ25-12 | 168 | 18.5 | 43.12 | |||||||||||||||||||
25 | 12 | 2850 | 65 | 135au-dessus de | 2.2 | 380 | 6.03 | 128 | ||||||||||||||
135QJ25-18 | 18 | 3 | 8.01 | |||||||||||||||||||
135QJ25-24 | 24 | 4 | 10.53 | |||||||||||||||||||
135QJ25-30 | 30 | 4 | 10.53 | |||||||||||||||||||
135QJ25-36 | 36 | 5.5 | 14.1 | |||||||||||||||||||
135QJ25-48 | 48 | 7.5 | 19.0 | |||||||||||||||||||
135QJ25-60 | 60 | 9.2 | 22.7 | |||||||||||||||||||
135QJ25-82 | 82 | 11 | 26.28 | |||||||||||||||||||
135QJ25-97 | 97 | 13 | 30.87 | |||||||||||||||||||
135QJ25-110 | 110 | 15 | 35.62 | |||||||||||||||||||
135QJ25-130 | 130 | 18.5 | 43.12 | |||||||||||||||||||
135QJ32-24 | 32 | 24 | 2850 | 80 | 135au-dessus de | 4 | 380 | 10.53 | 128 | |||||||||||||
135QJ32-30 | 30 | 5.5 | 14.1 | |||||||||||||||||||
135QJ32-42 | 42 | 7.5 | 19.0 | |||||||||||||||||||
135QJ32-54 | 54 | 9.2 | 22.7 | |||||||||||||||||||
135QJ32-68 | 68 | 11 | 26.28 | |||||||||||||||||||
135QJ32-80 | 80 | 13 | 30.87 | |||||||||||||||||||
135QJ32-92 | 92 | 15 | 35.62 | |||||||||||||||||||
135QJ32-104 | 104 | 18.5 | 43.12 | |||||||||||||||||||
135QJ40-46 | 40 | 46 | 2850 | 80 | 135au-dessus de | 11 | 380 | 26.28 | 128 | |||||||||||||
135QJ40-54 | 54 | 13 | 30.87 | |||||||||||||||||||
135QJ40-62 | 62 | 15 | 35.62 | |||||||||||||||||||
135QJ40-84 | 84 | 18.5 | 43.12 |
Well submersible pump is a clean water pump, it is strictly prohibited to dig a new well to extract mud and silt. The voltage grade of the well pump is 380/50HZ, and the submersible motor with other voltage grades needs to be customized. Underground cables must be waterproof and must be equipped with starting equipment, such as distribution box, etc. Starting equipment should have common motor comprehensive protection functions, such as short circuit overload protection, phase loss protection, undervoltage protection, grounding protection and idling protection, etc. In abnormal cases, the protection device should be timely tripping. When installing and using the pump, the pump must be reliably grounded, and it is prohibited to push and pull the switch when the hands and feet are wet. Before installing and maintaining the pump, the power must be cut off, and the place where the pump is used must be clearly marked "anti-electric shock". Before going down the well or installing the pump, the motor must be filled with distilled water or clean cold water without corrosion, and the intake/drain bolts must be tightened. When testing the pump on the ground, water must be poured into the pump chamber to lubricate the rubber bearings. The instant start time should not exceed one second to check whether the direction is correct. When using the pump, the lift and flow range specified by the pump must be strictly followed to prevent the pump from having a large flow at low lift or a large pull at high lift, which will lead to serious wear and tear of the thrust bearing and other parts and components, and cause the motor to overload and burn out. After the pump is put into the well, the insulation resistance between the motor and the ground should be measured, which should not be less than 100MΩ. After the start, the voltage and current should be observed regularly, and the motor winding insulation should be checked to see if it meets the requirements; if the temperature of the pump storage location is below the freezing point, the water in the motor cavity should be drained to prevent the water in the motor cavity from freezing and damaging the motor due to low temperature.
Brève introduction de la structure : la partie pompe est principalement composée d'un arbre de pompe, d'une turbine, d'une coque de dérivation, d'un roulement en caoutchouc, d'un corps de clapet anti-retour (pièces facultatives) et d'autres composants. La partie moteur est principalement composée d'une base, d'un film de régulation de pression, d'un palier de butée, d'une plaque de butée. , siège de roulement de guidage inférieur, stator, rotor, siège de roulement de guidage supérieur, anneau de sable, section d'entrée d'eau, câble et autres composants.
Les principales caractéristiques du produit comprennent :
1, le moteur est un moteur asynchrone triphasé submersible rempli d'eau, la cavité du moteur est pleine d'eau propre, utilisée pour refroidir le moteur et lubrifier le roulement, le film de régulation de pression au bas du moteur est utilisé pour ajuster la différence de pression d'expansion et de contraction de l'eau à l'intérieur du corps causée par le changement de l'augmentation de la température du moteur.
2, Afin d'empêcher le sable contenu dans l'eau du puits de pénétrer dans le moteur, l'extrémité supérieure de l'arbre du moteur est équipée de deux joints d'étanchéité et un anneau de sable est installé pour former une structure anti-sable.
3, Afin d'empêcher l'arbre de la pompe de monter lors du démarrage, l'arbre de la pompe et l'arbre du moteur sont reliés par un accouplement et un palier de butée supérieur est installé dans la partie inférieure du moteur.
4, la lubrification du moteur et du roulement de la pompe est une lubrification à l'eau.
5, l'enroulement du stator du moteur est constitué d'un fil d'enroulement de moteur submersible de haute qualité, avec des performances d'isolation élevées.
6, la pompe est conçue par CAO informatique, avec une structure simple et de bonnes performances techniques.

(1)Préparation avant installation :
1. Vérifiez si la pompe submersible répond aux conditions d'utilisation et à la portée spécifiées dans le manuel.
2. À l'aide d'un objet lourd d'un diamètre égal au diamètre extérieur maximum de la pompe submersible, mesurez si le diamètre intérieur du puits de forage peut s'adapter à la pompe submersible et mesurez si la profondeur du puits répond aux exigences d'installation.
3. Vérifiez si le puits de forage est propre et si l'eau du puits est trouble. N'utilisez jamais de pompe électrique submersible pour laver la boue et l'eau de sable de la pompe welor afin d'éviter des dommages prématurés à la pompe électrique submersible.
4. Vérifiez si la position de la pince d'installation de la tête de soudure est appropriée et si elle peut résister à la qualité de l'ensemble de l'unité.
5. Vérifiez si les composants de la pompe submersible sont complets et installés correctement selon le schéma d'assemblage dans le manuel. Retirez le tamis filtrant et faites tourner l'accouplement pour voir s'il tourne de manière flexible.
6. Dévissez la vis à eau et remplissez la cavité du moteur avec de l'eau propre et non corrosive (remarque : assurez-vous de la remplir), puis serrez la vis à eau. Après 12 heures d'injection d'eau, la résistance d'isolation du moteur ne doit pas être inférieure à 150 M Q lorsqu'elle est mesurée avec une table vibrante de 500 V.
7. Cable joint, cut off a 120mm rubber sleeve from one end of the outgoing cable and the matching cable with an electrician's knifethen stagger the length of the three core wires in a stepped shape, peel off a 20mm copper core, scrape of the oxide layer on theoutside of the copper wire with a knife or sand cloth, and insert the two connected wire ends in palirs.After tying the layer tightly with fine copper wire, solder it thoroughly and firmly, and sand of any. burrs on the surface. Then, forthe three joints, use polyvester insulation tape to wrap them in a semi stacked manner for three lavers. Wrap the two ends of thewrapping layer tightywith nyion thread,and then use a semi stacked method to wrap the tape for three layers. Wrap the outellayer with high-pressure insulation tape for three layers. Finally, fold the threestrands together and repeatedly wrap them for fivelayers with high-pressure tape. Each layer must be tightly tied, and the interlayer joints must be tight and fimm to prevent water frompenetrating and damaging the insulation, After wrapping, soak in water at room temperature of 20 ’c for 12 hours, and measurethe insulation resistance with a shaking table, which should not be less than 100M Ω
Le schéma du processus de câblage des câbles ci-joint est le suivant :
8. Utilisez un multimètre pour vérifier si les fils triphasés sont connectés et si la résistance CC est approximativement équilibrée.
9. Vérifiez si le circuit et la capacité du transformateur sont surchargés, puis connectez l'interrupteur de protection contre les surcharges ou l'équipement de démarrage. Voir le tableau 2 pour les modèles spécifiques, puis versez un seau d'eau dans la pompe à eau depuis la sortie de la pompe à eau pour lubrifier les roulements en caoutchouc de la pompe, puis placez la pompe électrique submersible verticale et stable. Démarrez (pas plus d'une seconde) et vérifiez si la direction de direction est cohérente avec le panneau de direction. Sinon, échangez deux connecteurs du câble triphasé. Installez ensuite le filtre et préparez-vous à descendre dans le puits. Si elle est utilisée dans des occasions spéciales (telles que fossés, fossés, rivières, étangs, étangs, etc.), la pompe électrique doit être mise à la terre de manière fiable.
(2)Équipement et outils d'installation :
1. Une paire de chaînes de levage pour plus de deux tonnes.
2. Un trépied d'une hauteur verticale d'au moins quatre mètres.
3. Deux cordes suspendues (câbles métalliques) pouvant supporter un poids de plus d'une tonne (peuvent supporter le poids d'un ensemble complet de pompes à eau).
4. Installez deux paires de pinces (attelles).
5. Clés, marteaux, tournevis, outils et instruments électriques, etc.
(3)Installation de pompe électrique :
1. Le schéma d'installation de l'électropompe submersible est illustré à la figure 2. Les dimensions d'installation spécifiques sont indiquées dans le tableau 3 « Liste des dimensions d'installation de l'électropompe submersible ».
2. Les pompes électriques submersibles d'une hauteur inférieure à 30 mètres peuvent être hissées directement dans le puits à l'aide de tuyaux et de câbles métalliques ou d'autres câbles de chanvre pouvant supporter tout le poids de la machine entière, des conduites d'eau et de l'eau dans les conduites.
3. Les pompes d'une hauteur de plus de 30 mètres utilisent des tuyaux en acier et la séquence d'installation est la suivante :
①Utilisez une pince pour serrer l'extrémité supérieure de la partie de la pompe à eau (le moteur et la pompe à eau ont été connectés à ce moment-là), soulevez-la avec une chaîne suspendue et attachez-la lentement dans le puits jusqu'à ce que vous mettiez la pince sur la tête de puits et retirez le chaîne suspendue.
② Utilisez une autre paire de colliers pour serrer un tuyau, soulevez-le avec une chaîne suspendue à 15 cm de la bride et abaissez-le lentement. Entre la bride du tuyau et la bride de la pompeMettez le tampon en caoutchouc en place et serrez le tuyau et la pompe uniformément avec des boulons, des écrous et des rondelles élastiques.
③ Soulevez légèrement la pompe submersible, retirez la pince à l'extrémité supérieure de la pompe à eau, attachez fermement le câble à la conduite d'eau avec un ruban en plastique et attachez-le lentement jusqu'à ce que la pince soit placée à la tête de puits.
④Utilisez la même méthode pour relier toutes les conduites d’eau au puits.
⑤ Une fois le câble de sortie connecté à l'interrupteur de commande, il est connecté à l'alimentation triphasée.
(4) Choses à noter lors de l’installation :
1. Si un phénomène de blocage est détecté pendant le processus de pompage, tournez ou tirez sur la conduite d'eau pour surmonter le point de blocage. Si diverses mesures ne fonctionnent toujours pas, veuillez ne pas forcer la pompe vers le bas pour éviter d'endommager la pompe électrique submersible et le puits.
2. Lors de l'installation, un tampon en caoutchouc doit être placé sur la bride de chaque tuyau et serré uniformément.
3. Lorsque la pompe à eau est abaissée dans le puits, elle doit être placée au milieu du tuyau du puits pour empêcher la pompe de fonctionner contre la paroi du puits pendant une longue période, provoquant ainsi la vibration de la pompe et le balayage et la combustion du moteur. .
4. Déterminez la profondeur de la pompe à eau jusqu'au fond du puits en fonction des conditions d'écoulement du sable et du limon du puits. N'enfouissez pas la pompe dans la boue. La distance entre la pompe à eau et le fond du puits n'est généralement pas inférieure à 3 mètres (voir Figure 2).
5. La profondeur d'entrée de l'eau de la pompe à eau ne doit pas être inférieure à 1 à 1,5 mètres entre le niveau d'eau dynamique et le nœud d'entrée d'eau (voir Figure 2). Sinon, les roulements de la pompe à eau pourraient être facilement endommagés.
6. La levée de la pompe à eau ne peut pas être trop faible. Sinon, un robinet-vanne doit être installé sur la canalisation d'eau de la tête de puits pour contrôler le débit de la pompe au point de débit nominal afin d'éviter que le moteur ne soit surchargé et grillé en raison de débits élevés.
7. Lorsque la pompe à eau fonctionne, le débit d'eau doit être continu et uniforme, le courant doit être stable (dans les conditions de travail nominales, généralement pas plus de 10 % du courant nominal) et il ne doit y avoir aucune vibration ni bruit. En cas d'anomalie, la machine doit être arrêtée pour en rechercher la cause et l'éliminer.
8. Lors de l'installation, faites attention au réglage du fil de terre du moteur (voir Figure 2). Lorsque la conduite d'eau est un tuyau en acier, faites-la sortir du collier de serrage de la tête de puits ; lorsque le tuyau d'eau est un tuyau en plastique, faites-le passer du repère de mise à la terre de la pompe électrique.
- 1. L'installation de la pompe submersible est terminée, revérifiez la résistance d'isolation et la conduction triphasée de l'interrupteur, vérifiez l'instrument et démarrez l'erreur de connexion de l'équipement, s'il n'y a pas de problème, vous pouvez commencer l'essai, après le démarrage de l'instrument. indiquant les lectures si la tension et le courant nominal sont supérieurs à la plaque signalétique, observez le bruit de la pompe et le phénomène de vibration, tout est normal peut être mis en service.
- 2. La première opération de la pompe pendant quatre heures doit être arrêtée rapidement pour tester la résistance d'isolation thermique du moteur, la valeur ne doit pas être inférieure à 0,5 mégaohm.
- 3. Après l'arrêt de la pompe, elle doit être démarrée après un intervalle de cinq minutes, pour éviter que la colonne d'eau dans le tuyau ne reflue complètement causée par un courant excessif du moteur et un grillage.
- 4. Une fois la pompe en fonctionnement normal, afin de prolonger sa durée de vie, pour vérifier la tension d'alimentation, le courant de fonctionnement et la résistance d'isolation sont normaux, si vous trouvez la situation suivante, vous devez immédiatement arrêter le dépannage.
- - à l'état nominal, le courant est supérieur à 20 %.
- - niveau d'eau dynamique à la section d'entrée d'eau, provoquant une eau intermittente.
- - pompe submersible vibrations ou bruit importants.
- - la tension d'alimentation est inférieure à 340 volts.
- - le fusible a grillé une phase.
- - dégâts sur les canalisations d'eau.
- - la résistance d'isolation thermique du moteur est inférieure à 0,5 mégaohm.
- 5. Démontage de l'unité :
- (1)untie cable tether, remove the pipeline part, remove the wire plate.
- (2)screw down the water bolt, put out the motor cavity water.
- (3)remove the filter, loosening the coupling fixed motor shaft fixed screw.
- (4)screw down the inlet joint and motor bolt, the pump and motor separate (separation attention will unit mat flat, prevent the pump shaft bending)
- (5)pump disassembly sequence is: (see figure 1) inlet joint, impeller, diversion shell, impeller...... check valve body, dismantle the impeller with special tools will first fix the conical sleeve loosening, the disassembly process to avoid the pump shaft bending and each bump.
- (6)motor disassembly process is: (see figure 1) the motor placed on the platform, from the bottom of the motor in turn removed double head bolt (pull rod bolt) on the nut, base, shaft head lock nut, thrust plate, key, lower guide bearing seat, double head bolt, and then take out the rotor (pay attention not to damage the wire package) finally removed the connecting section and upper guide bearing seat.
- (7)unit assembly: before assembly should be the parts of the rust, dirt clean, each mating surface and fastener coated with sealant, and then in turn according to the reverse sequence of disassembly assembly (after assembly motor shaft up and down momentum is about one millimeter), after assembly, the coupling should be flexible, and then the filter screen test machine.
- 6.submersible pump every operation for a year, or less than a year of operation but the submersible time has reached two years, should be proposed in accordance with the fifth paragraph of the well to be dismantled and repaired, replace the worn parts.
This product is a brand new submersible pump, suitable for a variety of occasions for pump work needs. In order to ensure the long-term use and stable performance of the product, the user needs to clean the water in the motor cavity of the pump after use (especially in winter to prevent the motor from freezing), coil up and tie the cable, and then store the product in an environment free of corrosive substances and gases, with the temperature kept below 40 °C in the room. In addition, if the submersible pump is not used for a long time, special attention should be paid to prevent rust to protect the service life of the product. This submersible pump will provide users with convenient and efficient pump solutions to ensure the safe and stable operation of the pump equipment.
- Turbine
- Manchon d'arbre
- Manchon d'arbre en caoutchouc
-
Bague d'étanchéité
01 Prise d'eau de puits profond
02 Approvisionnement en eau en hauteur
03 approvisionnement en eau de montagne
04 tour d'eau
05 Irrigation agricole
06 arrosage du jardin
07 prise d'eau de rivière
08 eau domestique