Pompa głębinowa 135QJ do studni głębinowych

Podejmij się przetwarzania OEM! Zgodnie z wymaganiami użytkownika, projektowanie i produkcja różnego rodzaju specjalnych wymagań niestandardowych silników głębinowych i pomp. Normy wdrożeniowe produktu: GB/T2816-2014 „studnia pompa głębinowa”, GB/T2818-2014 „studniowy silnik asynchroniczny”. WhatsApp: 17855846335
PDF DOWNLOAD
Detale
Tagi
 
Przegląd produktów

QJ series submersible pump is a kind of lifting machine directly connected to the submersible motor and pump to work in the water. This series of pumps is vertical, small footprint, compact structure, simple installation, easy maintenance and repair. It is widely used in agricultural irrigation, municipal engineering, water conservancy projects, urban water supply and drainage and industrial and mining enterprises, drought relief and drainage, etc. The flow range is 5-500m3/h, the head is 4-800m, and the power is 3-315KW. This submersible pump can efficiently lift and transport water, providing reliable water supply for various fields. Its stable performance and solid structure make it an indispensable machine and equipment for various water conservancy projects.

 

 
Warunki użytkowania

The power supply of this product is three-phase AC 380V (tolerance ± 5%), 50HZ (tolerance ± 1%).

The water quality shall meet the following requirements:

(1) the water temperature shall not be higher than 20 °C;

(2) the content of solid impurities (mass ratio) shall not exceed 0.01%;

(3) the PH value (acidity and alkalinity) is 6.5-8.5;

(4) the content of hydrogen sulfide shall not exceed 1.5mg/L;

(5) the content of chloride ions shall not be higher than 400mg/L.

The motor is a closed or water-immersed wet structure. Before use, the inner cavity of the submersible motor shall be filled with water to prevent empty, and then the water injection and air exhaust bolts shall be tightened, otherwise it shall not be used. The submersible pump must be completely immersed in water to work, and the immersion depth shall not exceed 70 meters, and the distance between the bottom of the pump and the bottom of the well shall not be less than 3 meters. The well water inflow shall meet the water output and continuous operation requirements of the submersible pump, and the output water shall be controlled at 0.7-1.2 times of the rated flow. The well shall be vertical, and the submersible pump shall not be used horizontally or inclined, but only vertically. The submersible pump shall be equipped with cables as required, and equipped with external overload protection devices. It is strictly prohibited to conduct no-water no-load test on the pump.

 

 
Znaczenie modelu

Read More About 3in submersible well pump

 
Częściowe odniesienie do modelu
Model Przepływ (m3/h)   Głowa
(M)

  Prędkość obrotowa

(zmiana/punkt)

 Pompa wodna(%)   Wylot
średnica
(mm)
Dobrze się sprawdza
średnica (mm) 
Oceniono
moc (KW)
Oceniono
napięcie (V)
 Oceniono
prąd (A)
Sprawność motoryczna (%)  power factorcosφ   Jednostka
Maksymalny rozmiar promieniowy (mm)
Uwaga
135QJ5-34 5 34 2850   40  135powyżej 1.5 380 4.23     128  
135QJ5-51 51 2.2 6.03      
135QJ5-68 68 3 8.01      
135QJ5-85 85 4 10.53      
135QJ5-102 102 5.5 14.1      
135QJ5-119 119 5.5 14.1      
135QJ5-240 240 11 26.28      
135QJ5-280 5 280 2850   40  135powyżej 13 380 30.87     128  
135QJ5-320 320 15 35.62      
135QJ10-24 10 24 2850   50  135powyżej 1.5 380 4.23     128  
135QJ10-32 32 2.2 6.03      
135QJ10-48 48 3 8.01      
135QJ10-56 56 4 10.53      
135QJ10-72 72 5.5 14.1      
135QJ10-80 80 5.5 14.1      
135QJ10-104 104 7.5 19.0      
135QJ10-120 120 7.5 19.0      
135QJ10-136 136 9.2 22.7      
135QJ10-180 180 11 26.28      
135QJ10-210 210 13 30.87      
135QJ10-240 240 15 35.62      
135QJ10-300 300 18.5 43.12      
135QJ15-36 15 36 2850   50  135powyżej 2.2 380 6.03     128  
135QJ15-39 39 3 8.01      
135QJ15-46 46 4 10.53      
135QJ15-52 52 4 10.53      
135QJ15-59 59 5.5 14.1      
135QJ15-65 65 5.5 14.1      
135QJ15-78 78 7.5 19.0      
135QJ15-91 91 7.5 19.0      
135QJ15-104 104 9.2 22.7      
135QJ15-120 120 11 26.28      
135QJ15-142 142 13 30.87      
135QJ15-162 162 15 35.62      
135QJ15-200 200 18.5 43.12      
135QJ20-16 20 16 2850   50  135above 2.2 380 6.03     128  
135QJ20-24 24 3 8.01      
135QJ20-32 32 4 10.53      
135QJ20-40 40 4 10.53      
135QJ20-48 48 5.5 14.1      
135QJ20-56 56 5.5 14.1      
135QJ20-64 64 7.5 19.0      
135QJ20-72 72 7.5 19.0      
 135QJ20-80135QJ20-100 80 9.2 22.7      
100 11 26.28      
135QJ20-120 120 13 30.87      
135QJ20-136 136 15 35.62      
 135QJ20-168135QJ25-12 168 18.5 43.12      
25 12 2850   65  135powyżej 2.2 380 6.03     128  
135QJ25-18 18 3 8.01      
135QJ25-24 24 4 10.53      
135QJ25-30 30 4 10.53      
135QJ25-36 36 5.5 14.1      
135QJ25-48 48 7.5 19.0      
135QJ25-60 60 9.2 22.7      
135QJ25-82 82 11 26.28      
135QJ25-97 97 13 30.87      
135QJ25-110 110 15 35.62      
135QJ25-130 130 18.5 43.12      
135QJ32-24 32 24 2850   80  135powyżej 4 380 10.53     128  
135QJ32-30 30 5.5 14.1      
135QJ32-42 42 7.5 19.0      
135QJ32-54 54 9.2 22.7      
135QJ32-68 68 11 26.28      
135QJ32-80 80 13 30.87      
135QJ32-92 92 15 35.62      
135QJ32-104 104 18.5 43.12      
135QJ40-46 40 46 2850   80  135powyżej 11 380 26.28     128  
135QJ40-54 54 13 30.87      
135QJ40-62 62 15 35.62      
135QJ40-84 84 18.5 43.12      

 

 
Środki ostrożności

1, studnia głębinowa do pompy czystej wody, zabrania nowej studni, pompowania osadów i błotnistej wody,

2, napięcie pompy wody studziennej 380/50 HZ, zastosowanie innych stopni napięcia silników podwodnych musi zostać dostosowane. Kabel podziemny musi być wodoodporny, musi być wyposażony w sprzęt rozruchowy, taki jak skrzynka rozdzielcza, rozruch nie jest gotowy, powinien mieć powszechnie stosowaną kompleksową funkcję ochrony silnika, taką jak zabezpieczenie przed przeciążeniem zwarciowym, zabezpieczenie fazowe, zabezpieczenie podnapięciowe, zabezpieczenie doziemne, zabezpieczenie na biegu jałowym w przypadku nienormalnych warunków urządzenie zabezpieczające powinno zadziałać w odpowiednim czasie.

3, instalacja i użytkowanie pompy muszą być niezawodnie uziemione, uniemożliwia wciśnięcie i pociągnięcie przełącznika, gdy ręce i stopy są mokre, należy odciąć zasilanie przed instalacją i konserwacją pompy, należy używać miejsca do ustawienia pompy” aby zapobiec porażeniu prądem” oczywiste znaki:

4, w dół studni lub przed instalacją, komorę silnika należy wypełnić wodą destylowaną lub niekorozyjną, czystą, zimną wrzącą wodą, dokręcić śrubę wodną, ​​pompa na ziemi musi być uruchomiona próbnie, musi znajdować się w komorze pompy guma smarująca wodą łożyska, natychmiastowy start nie dłuższy niż sekunda, sprawdź, czy sterowanie jest takie samo jak instrukcja sterowania. Gdy pompa jest ustawiona pionowo, należy zwrócić uwagę na bezpieczeństwo, aby uniknąć obrażeń spowodowanych wywróceniem.

5, ściśle według przepisów dotyczących podnoszenia pompy, zakresu przepływu, aby zapobiec niskiemu lub dużemu przepływowi siły pompowania, łożysku oporowemu i innym częściom zużycia, spaleniu przeciążenia silnika

6, after the pump down the well, the measurement of the motor to the ground insulation resistance should not be less than 100M, after the start to observe the voltage and current, check the motor winding insulation, whether in line with the requirements; pump storage location temperature if less than freezing point, should be dry the motor cavity water, prevent the motor cavity water ice damage caused by low temperature.

 

 
Wprowadzenie do struktury

1.Structure brief: pump part is mainly composed of pump shaft, impeller, diversion shell, rubber bearing, check valve body (optional parts) and other components. The motor part is mainly composed of base, pressure regulating film, thrust bearing, thrust plate, lower guide bearing seat, stator, rotor, upper guide bearing seat, sand throwing ring, water inlet node, cable and other components

2.The main feature of this product is the use of water-cooled wet submersible three-phase asynchronous motor. The motor chamber is filled with water, used to cool the motor and lubricate the bearing. The voltage regulating film at the bottom is used to adjust the pressure difference caused by the temperature rise of the motor. In order to prevent the sand in the well water from entering the motor, two oil seals are installed on the top of the motor shaft extension end, and a sand throwing ring is installed to form a sand control structure. This design ensures the long-term reliability and stability of the motor, which is an ideal choice for pump users.

3. In order to prevent the pump shaft from running up when starting, the pump shaft and the motor shaft are connected by a coupling, and an upper thrust bearing is installed under the motor.

4.The lubrication of the motor and the pump bearing is water lubrication.

5.he motor stator winding is made of high quality submersible motor winding wire, with high insulation performance.

6. The pump is designed by computer CAD, with simple structure and good technical performance.

Read More About 1 2 hp water pump price
 
zainstalować

(1) Przygotowanie przed instalacją:
1. Sprawdź, czy pompa głębinowa spełnia warunki użytkowania i zakres określony w instrukcji.
2. Za pomocą ciężkiego przedmiotu o średnicy równej maksymalnej średnicy zewnętrznej pompy głębinowej zmierzyć, czy średnica wewnętrzna odwiertu zmieści się w pompie głębinowej oraz zmierzyć, czy głębokość studni spełnia wymagania montażowe.
3. Sprawdź, czy odwiert jest czysty i czy woda w studni jest mętna. Nigdy nie używaj elektrycznej pompy głębinowej do mycia błota i piasku z pompy Welor, aby uniknąć przedwczesnego uszkodzenia pompy elektrycznej.
4. Sprawdź, czy pozycja zacisku montażowego głowicy spawalniczej jest odpowiednia i czy wytrzyma jakość całego urządzenia
5. Sprawdź czy elementy pompy głębinowej są kompletne i prawidłowo zamontowane zgodnie ze schematem montażu zawartym w instrukcji. Zdejmij sito filtra i obróć sprzęgło, aby sprawdzić, czy obraca się elastycznie
6. Odkręć śrubę wodną i napełnij komorę silnika czystą, niekorozyjną wodą (pamiętaj o jej napełnieniu), a następnie dokręć śrubę wodną. Po 12 godzinach wtrysku wody rezystancja izolacji silnika nie powinna być mniejsza niż 150M Q, mierzona za pomocą stołu wibracyjnego 500V.
7. Cable joint, cut off a 120mm rubber sleeve from one end of the outgoing cable and the matching cable with an electrician's knifethen stagger the length of the three core wires in a stepped shape, peel off a 20mm copper core, scrape of the oxide layer on theoutside of the copper wire with a knife or sand cloth, and insert the two connected wire ends in palirs.After tying the layer tightly with fine copper wire, solder it thoroughly and firmly, and sand of any. burrs on the surface. Then, forthe three joints, use polyvester insulation tape to wrap them in a semi stacked manner for three lavers. Wrap the two ends of thewrapping layer tightywith nyion thread,and then use a semi stacked method to wrap the tape for three layers. Wrap the outellayer with high-pressure insulation tape for three layers. Finally, fold the threestrands together and repeatedly wrap them for fivelayers with high-pressure tape. Each layer must be tightly tied, and the interlayer joints must be tight and fimm to prevent water frompenetrating and damaging the insulation, After wrapping, soak in water at room temperature of 20 ’c for 12 hours, and measurethe insulation resistance with a shaking table, which should not be less than 100M Ω

 

Załączony schemat procesu okablowania kabla jest następujący:
Read More About submersible well pump 1.5 hp

 

8. Za pomocą multimetru sprawdź, czy przewody trójfazowe są podłączone i czy rezystancja prądu stałego jest w przybliżeniu zrównoważona.
9. Sprawdź, czy obwód i moc transformatora nie są przeciążone, a następnie podłącz wyłącznik zabezpieczający przed przeciążeniem lub sprzęt rozruchowy. Aby zapoznać się z konkretnymi modelami, patrz Tabela 2, a następnie wlej wiadro wody do pompy wodnej z wylotu pompy wodnej, aby nasmarować gumowe łożyska pompy, a następnie umieść elektryczną pompę głębinową pionowo i stabilnie. Uruchomienie (nie dłużej niż jedna sekunda) i sprawdź, czy kierunek skrętu jest zgodny ze znakiem skrętu. Jeśli nie, zamień dowolne dwie wtyczki kabla trójfazowego. Następnie zainstaluj filtr i przygotuj się do zejścia do studni. W przypadku używania pompy elektrycznej do specjalnych celów (takich jak rowy, rowy, rzeki, stawy, stawy itp.) pompa elektryczna musi być niezawodnie uziemiona.

 

(2) Sprzęt i narzędzia instalacyjne:
1. Jedna para łańcuchów do podnoszenia na ponad dwie tony.
2. Statyw o wysokości pionowej nie mniejszej niż cztery metry.
3. Dwie wiszące liny (liny stalowe) o wytrzymałości większej niż jedna tona (mogą udźwignąć ciężar kompletnego zestawu pomp wodnych).
4. Zamontuj dwie pary zacisków (szyn).
5. Klucze, młotki, śrubokręty, narzędzia i przyrządy elektryczne itp.

 

(3) Instalacja pompy elektrycznej:
1. Schemat instalacji elektrycznej pompy głębinowej pokazano na rysunku 2. Konkretne wymiary montażowe pokazano w Tabeli 3 „Wykaz wymiarów montażowych pompy elektrycznej głębinowej”.

 

2. Zatapialne pompy elektryczne o wysokości podnoszenia mniejszej niż 30 metrów można wciągać bezpośrednio do studni za pomocą węży i ​​lin stalowych lub innych lin konopnych, które są w stanie unieść cały ciężar całej maszyny, rur wodociągowych i wody w rurach.

 

3. W pompach o wysokości podnoszenia większej niż 30 metrów stosuje się rury stalowe, a kolejność montażu jest następująca:
①Użyj zacisku, aby zacisnąć górny koniec części pompy wodnej (silnik i pompa wodna zostały w tym czasie połączone), podnieś ją za pomocą wiszącego łańcucha i powoli przymocuj do studni, aż założysz zacisk na głowicę odwiertu i zdemontujesz wiszący łańcuch.
② Użyj kolejnej pary zacisków, aby zacisnąć rurę, podnieś ją za pomocą wiszącego łańcucha w odległości 15 cm od kołnierza i powoli opuść. Pomiędzy kołnierzem rury a kołnierzem pompy Załóż gumową podkładkę i równomiernie dokręć rurę i pompę za pomocą śrub, nakrętek i podkładek sprężystych.
③ Lekko podnieś pompę głębinową, zdejmij zacisk na górnym końcu pompy wodnej, mocno przymocuj kabel do rury wodnej za pomocą plastikowej taśmy i powoli zamocuj, aż zacisk zostanie umieszczony na głowicy odwiertu.
④Użyj tej samej metody, aby podłączyć wszystkie rury wodociągowe do studni.
⑤Po podłączeniu kabla wyjściowego do przełącznika sterującego, należy go podłączyć do trójfazowego źródła zasilania.


(4) Rzeczy, na które należy zwrócić uwagę podczas instalacji:
1. Jeśli podczas pompowania zostanie stwierdzone zjawisko zakleszczenia, obróć lub pociągnij rurę wodną, ​​aby pokonać punkt zakleszczenia. Jeśli różne środki nadal nie pomagają, nie należy opuszczać pompy na siłę, aby uniknąć uszkodzenia elektrycznej pompy głębinowej i studni.
2. Podczas montażu należy na kołnierz każdej rury założyć podkładkę gumową i równomiernie ją dokręcić.
3. Po opuszczeniu pompy wodnej do studni należy ją umieścić na środku rury studni, aby zapobiec długotrwałemu uderzaniu pompy o ścianę studni, powodując wibrację pompy oraz zamiatanie i spalanie silnika .
4. Określ głębokość pompy wodnej do dna studni, zgodnie z warunkami przepływu piasku i mułu w studni. Nie zakopuj pompy w błocie. Odległość pompy wodnej od dna studni na ogół nie jest mniejsza niż 3 metry (patrz rysunek 2).
5. Głębokość wejścia wody do pompy wodnej nie powinna być mniejsza niż 1-1,5 metra od dynamicznego poziomu wody do węzła wlotu wody (patrz rysunek 2). W przeciwnym razie łożyska pompy wodnej mogą łatwo ulec uszkodzeniu.
6. Podnoszenie pompy wodnej nie może być zbyt niskie. W przeciwnym razie na rurociągu wody głowicy odwiertu należy zainstalować zasuwę, aby kontrolować przepływ pompy w znamionowym punkcie przepływu, aby zapobiec przeciążeniu i spaleniu silnika z powodu dużych prędkości przepływu.
7. Gdy pompa wodna pracuje, wydatek wody powinien być ciągły i równy, prąd powinien być stabilny (w znamionowych warunkach pracy, na ogół nie więcej niż 10% prądu znamionowego), nie powinno być żadnych wibracji ani hałasu. Jeśli wystąpią jakiekolwiek nieprawidłowości, należy zatrzymać maszynę, aby znaleźć przyczynę i ją wyeliminować.
8. Podczas montażu należy zwrócić uwagę na ustawienie przewodu uziemiającego silnik (patrz rysunek 2). Jeżeli rura wodna jest rurą stalową, należy ją poprowadzić od obejmy głowicy odwiertu; jeśli rura wodna jest rurą z tworzywa sztucznego, poprowadź ją od znaku uziemienia pompy elektrycznej.

 

 
Konserwacja i konserwacja
  1. (1)After installing the submersible pump, it is necessary to recheck the insulation resistance and three-phase continuity of the switch, and check whether there are errors in the connection between the instrument and the starting equipment. If there is no problem, the test machine can be started. After starting, observe whether the indication readings of the instruments exceed the rated voltage and current specified on the nameplate, and observe whether the pump has noise and vibration. If everything is normal, it can be put into operation.
  2. (2)After the first operation of the pump for four hours, the motor should be shut down to test the thermal insulation resistance quickly, and its value should not be less than 0.5 megaohm.
  3. (3)After the pump is shut down, it should be started after five minutes to prevent the water column in the pipe from being completely reflowed and causing excessive motor current and burnout.
  4. (4)After the pump is put into normal operation, in order to prolong its service life, it is necessary to check whether the supply voltage, working current and insulation resistance are normal regularly. If the following conditions are found, the pump should be shut down immediately to troubleshoot.
  5.  

 1 In the rated condition, the current exceeds 20%.

 2 Dynamiczny poziom wody spada do sekcji wlotu wody, powodując okresowe pojawianie się wody.

 3 W pompie głębinowej występują silne wibracje lub hałas.

 4 Napięcie zasilania jest niższe niż 340 woltów.

 5 Przepalony bezpiecznik.

 6 Rura doprowadzająca wodę jest uszkodzona.

 7 The motor's thermal insulation resistance is lower than 0.5 megaohm.

 

  1. (5)Unit disassembly:
  2.  1 odwiązać linę kablową, zdjąć część rurociągu, zdjąć płytkę drucianą.

 2 przykręć śrubę wodną, ​​wlej wodę do komory silnika.

 3 wyjmij filtr, poluzuj stałą śrubę na sprzęgle, aby zamocować wał silnika.

 4 przykręcić śrubę łączącą złącze wlotowe z silnikiem i odłączyć pompę od silnika (przy demontażu zwrócić uwagę na poduszkę zespołu, aby zapobiec wygięciu wału pompy)

 5 kolejność demontażu pompy jest następująca: (patrz rysunek 1) złącze wlotowe, wirnik, osłona zwrotna, wirnik...... korpus zaworu zwrotnego, podczas demontażu wirnika należy użyć specjalnych narzędzi, aby poluzować tuleję stożkową nieruchomego wirnika w pierwszej kolejności i unikać zginania i stłuczeń wału pompy podczas demontażu.

 6 proces demontażu silnika obejmuje: (patrz rysunek 1) umieść silnik na platformie i wyjmij nakrętki, podstawę, nakrętkę zabezpieczającą łeb wału, płytkę oporową, wpust, dolne gniazdo łożyska prowadzącego i śrubę z podwójnym łbem od spodu silnik po kolei, a następnie wyjmij wirnik (zwróć uwagę, aby nie uszkodzić wiązki przewodów) i na koniec wyjmij sekcję łączącą i górne gniazdo łożyska prowadzącego.

 7 unit assembly: before assembly, the rust and dirt of the parts should be cleaned, and the mating surface and fasteners should be coated with sealant, and then assembled in the opposite order of disassembly (the momentum of the motor shaft is about one millimeter after assembly), after assembly, the coupling should be flexible, and then the filter screen test machine. 6. The submersible pump is known for its durability and efficiency, providing you with a lasting pumping solution. When the operating time is more than one year per year, or if the operating time is less than one year, but the immersion time is up to two years, it must be disassembled and inspected in accordance with Article 5 to replace the worn parts. This pump is well designed to ensure efficient operation and reliability, so that you can rest assured. Whether it is used for pumping water from a family pond or pumping water for agricultural irrigation systems, this product can meet your needs. Choose this high-quality pump to keep your pump system in the best condition at all times, ensuring smooth operation and extending its service life.

 

 
Przechowywanie i opieka

 1, wypuść wodę z komory silnika (szczególnie zimą, aby zapobiec zamarznięciu silnika) i dobrze zawiąż kabel.

 2, store in an indoor room without corrosive substances and gases, with a temperature below 40 °C.

 3, przy długotrwałym użytkowaniu należy zwrócić uwagę na zapobieganie rdzy pomp głębinowych.

 

 
Części zużywające się

 

  • Wirnik
  • Tuleja wału
  • Gumowa tuleja wału
  • Uszczelka

 
Scenariusze zastosowań

01 Ujęcie wody ze studni głębinowej

02 Wysokie źródło wody

03 zaopatrzenie w wodę w górach 

04 wieża wodna

05 Nawadnianie rolnictwa

06 nawadnianie ogrodu

07 ujęcie wody rzecznej

08 woda użytkowa

 

Jeśli jesteś zainteresowany naszymi produktami, możesz zostawić tutaj swoje dane, a my wkrótce się z Tobą skontaktujemy.


Napisz tutaj swoją wiadomość i wyślij ją do nas

Jeśli jesteś zainteresowany naszymi produktami, możesz zostawić tutaj swoje dane, a my wkrótce się z Tobą skontaktujemy.


pl_PLPolish