This product adopts a variable frequency winding design, ensuring the motor's smooth conversion operation between 1HZ and 50HZ for a long time. This innovative design not only saves energy and prolongs service life, but also provides lasting and reliable performance in the work process. Whether in a home or industrial environment, this product will provide users with excellent efficiency and reliability, making it an indispensable tool in the manufacturing and production process.
1, ike ọkọnọ: atọ-adọ AC 380V ( ndidi + / - 5%), 50HZ ( ndidi + / - 1%).
2, ogo mmiri:
(1) mmiri okpomọkụ adịghị elu karịa 20 Celsius;
(2) ọdịnaya adịghị ọcha siri ike (oke oke) adịghị elu karịa 0.01%;
(3) PH uru (pH) 6.5-8.5;
(4) hydrogen sulfide ọdịnaya abụghị ihe karịrị 1.5mg / L;
(5) Ọdịnaya ion chloride adịghị elu karịa 400mg/L.
3, moto na-emechi ma ọ bụ mmiri jupụtara mmiri Ọdịdị, tupu eji submersible moto oghere ga-ejupụta na mmiri dị ọcha, iji gbochie ụgha zuru, na mgbe ahụ ikesiike mmiri injection, ikuku ntọhapụ bolts, ma ọ bụghị ekwe ka iji.
4, submersible pump must be completely submerged in the water, the diving depth is not greater than 70m, the bottom of the submersible pump from the bottom of the well is not less than 3m. 5, the well water flow should be able to meet the submersible pump water output and continuous operation, the submersible pump water output should be controlled at 0.7 - 1.2 times the rated flow.
6, olulu mmiri kwesịrị ịdị ogologo, enweghị ike iji ma ọ bụ tụfuo mgbapụta submersible, naanị iji kwụ ọtọ.
7, mgbapụta nke submersible ga-adaba na eriri dị ka ihe ndị a chọrọ, na ngwaọrụ nchebe nke mpụga.
8, a na-amachibido mgbapụta ahụ nke ọma na-enweghị igwe nyocha enweghị mmiri
Nlereanya | Ọsọ (m3/h) | Isi (m) |
Ọsọ ntụgharị (mgbanwe/atụ) |
Mgbapu mmiri(%) | Mwepu dayameta (mm) |
Ọdabara nke ọma dayameta (mm) |
Enyere aha power(KW) |
Enyere aha voltaji (V) |
Enyere aha ugbu a (A) |
Ịrụ moto (%) | ike factorcos | Nkeji Nha radial kacha (mm) |
kwuo | |||||||||
300QJ200-40 | 200 | 40 | 2900 | 76 | 150 | 300n'elu | 37 | 380 | 77.8 | 85.0 | 0.85 | 281 | ||||||||||
300QJ200-60 | 60 | 55 | 115 | 85.5 | 0.85 | |||||||||||||||||
300QJ200-80 | 80 | 75 | 154.1 | 86.0 | 0.86 | |||||||||||||||||
300QJ200-100 | 100 | 90 | 183.8 | 86.5 | 0.86 | |||||||||||||||||
300QJ200-120 | 120 | 100 | 204.3 | 86.5 | 0.86 | |||||||||||||||||
300QJ200-140 | 140 | 125 | 249.5 | 87.5 | 0.87 | |||||||||||||||||
300QJ200-160 | 160 | 140 | 277.8 | 88.0 | 0.87 | |||||||||||||||||
300QJ200-180 | 180 | 160 | 317.5 | 88.0 | 0.87 | |||||||||||||||||
300QJ200-200 | 200 | 185 | 367.2 | 88.0 | 0.87 | |||||||||||||||||
300QJ200-240 | 240 | 220 | 436.6 | 88.0 | 0.87 | |||||||||||||||||
300QJ320-30 | 320 | 30 | 2900 | 77 | 200 | 300n'elu | 45 | 380 | 94.6 | 85.0 | 0.85 | 281 | ||||||||||
300QJ320-60 | 60 | 90 | 183.8 | 86.5 | 0.86 | |||||||||||||||||
300QJ320-90 | 90 | 125 | 249.5 | 87.5 | 0.87 | |||||||||||||||||
300QJ320-120 | 120 | 160 | 317.5 | 88.0 | 0.87 |
This well submersible pump is a pump suitable for clean water. It is strictly prohibited to dig new wells and pump dirty water containing sediment. The voltage grade of the pump is 380/50HZ, and other submersible motors with different voltage grades need to be customized. Underground cables must be waterproof cables and must be equipped with starting equipment, such as distribution boxes, etc. The starting equipment should have common comprehensive motor protection functions, such as short circuit overload protection, dephase protection, undervoltage protection, grounding protection and idling protection, etc., in order to prevent timely tripping when abnormal conditions occur. During the installation and use process, the pump must have reliable grounding. It is strictly prohibited to push and pull the switch when your hands and feet are wet. The power supply must be cut off before installation and maintenance of the pump. An obvious sign "anti-electric shock" must be set up where the pump is used. Before going down the well or installation, the motor must be filled with distilled water or non-corrosive clean cold water, and the water inlet and outlet bolts must be tightened. When testing the pump on the ground, water must be filled into the pump chamber to lubricate the rubber bearings. The instant start time shall not exceed one second to check whether the steering is correct. Pay attention to safety when the pump is upright to prevent toppling and injury. Strictly in accordance with the provisions of the pump lift and flow range, to prevent the pump with a large flow at low lift or produce a large pull at high lift, resulting in extreme wear of thrust bearings and other parts, the motor overload and burn. After the pump into the well, the measurement of the motor to the ground insulation resistance should not be less than 100MΩ. After starting, regularly observe the voltage and current, and check whether the motor winding insulation meets the requirements; if the pump storage temperature below freezing point, should be drained to prevent the water in the motor cavity from freezing and cause the motor damage due to low temperature.
The pump part is mainly composed of pump shaft, impeller, shunt shell, rubber bearing, check valve body (optional) and other components. The motor part is mainly composed of base, pressure regulating diaphragm, thrust bearing, thrust plate, lower guide bearing seat, stator, rotor, upper guide bearing seat, sand ring, water inlet section, lead cable and other components.
Isi njirimara ngwaahịa a gụnyere:
- 1.The motor is a water-filled wet submersible three-phase asynchronous motor. The motor cavity is filled with clean water, used to cool the motor and lubricate the bearing. The pressure regulating diaphragm at the bottom of the motor is used to adjust the expansion and contraction pressure difference of the water in the body caused by the temperature rise of the motor.
- 2. In order to prevent the sand particles from entering the motor, two sand seals are installed at the upper end of the motor shaft extension, and a sand control structure is formed by installing the sand ring.
- 3. In order to prevent the pump shaft from jumping when starting, the pump shaft is connected with the motor shaft through a coupling, and the thrust bearing is installed at the bottom of the motor.
- 4. The lubrication method of the motor and the pump bearing is water lubrication.
- 5. The stator winding of the motor adopts high quality submersible motor winding wire with high insulation performance.
- 6. The pump is designed by computer CAD, with simple structure and excellent technical performance.

(1) Nkwadebe tupu echichi:
1. Lelee ma mgbapụta submersible na-ezute ọnọdụ ojiji yana oke akọwapụtara na ntuziaka.
2. Iji obiect dị arọ nke nwere dayameta hà nhata kachasị elu nke mgbapụta mmiri na-ekpuchi mmiri, tụọ ma inneldiameter nke olulu mmiri ahụ nwere ike dabara na mgbapụta mmiri, ma tụọ ma omimi nke ọma na-emezu ihe achọrọ nrụnye.
3. Lelee ma olulu mmiri ahụ ọ dị ọcha ma mmiri olulu mmiri ahụ ọ na-asọ oyi. Ejila mgbapụta ọkụ eletrik na-eme ka mmiri na-asachapụ apịtị welor na mmiri ájá ka ịzenarị mmebi nke mgbapụta ọkụ eletrik n'oge.
4. Lelee ma ọnọdụ nke welhead echichi mwekota dabara na ma ọ nwere ike iguzogide qualty nke dum unit.
5. Lelee ma ọ bụrụ na akụrụngwa mgbapụta submersible zuru ezu ma wụnye ya nke ọma dị ka eserese mgbakọ na mwepụ na akwụkwọ ntuziaka Wepụ ihuenyo nzacha ma gbanwee njikọ ahụ iji hụ ma ọ na-agbagharị na-agbanwe agbanwe.
6. Kpochapụ ihe nkedo mmiri ma jupụta oghere moto na mmiri dị ọcha, nke na-adịghị emebi emebi (dee. jide n'aka na ị ga-agbanye ya), wee mee ka mmiri sie ike. Mgbe awa 12 nke ịgbanye mmiri gasịrị, nguzogide mkpuchi nke moto ekwesịghị ịbụ ihe na-erughị 150M Q mgbe a tụrụ ya na tebụl ịma jijiji 500V.
7. Njikọ eriri USB, bepụ aka uwe roba 120mm site na otu njedebe nke eriri na-apụ apụ na eriri dabara na ya na mma eletriki wee tụọ ogologo eriri isi atọ ahụ n'ụdị steepụ, wepụ isi ọla kọpa 20mm, kpochapu oxide. oyi akwa na theside nke ọla kọpa waya na mma ma ọ bụ ájá ákwà, na fanye abụọ ejikọrọ waya agwụ na palirs.Mgbe ekekọta oyi akwa tightly na ezi ọla kọpa waya, solder ya nke ọma na ike, na ájá nke ọ bụla. burrs n'elu. Mgbe ahụ, maka nkwonkwo atọ ahụ, jiri teepu mkpuchi mkpuchi polyvester kechie ha n'ụzọ dị nkenke nke etinyere maka ọdọ mmiri atọ. Jiri eriri nyion kechie nsọtụ abụọ nke oyi akwa mkpuchi, wee jiri usoro echekwabara ọkara wee kechie teepu ahụ maka ọkwa atọ. Kechie outellayer na teepu mkpuchi mkpuchi dị elu maka ọkwa atọ. N'ikpeazụ, jikọta eriri atọ ahụ ma kechie ha ugboro ugboro maka ihe ise na teepu dị elu. A ghaghị ijikọta oyi akwa nke ọ bụla, na nkwonkwo interlayer ga-adị ike na fimm ka mmiri ghara ịbanye ma mebie ihe mkpuchi ahụ, Mgbe ị na-ekpuchi ya, gbanye n'ime mmiri na okpomọkụ nke 20 'c maka awa 12, wee tụọ nguzogide mkpuchi na tebụl na-ama jijiji. , nke ekwesịghị ịbụ ihe na-erughị 100M Ω
Eserese usoro wiring cable nke agbakwunyere bụ nke a:
8. Jiri multimeter chọpụta ma ejikọrọ wires nke atọ na ma nkwụsi ike DC ọ dị oke nhata.
9. Lelee ma ikike sekit na transformer bubigara ibu, wee jikọọ ihe ngbanwe mkpuchi ibufe ma ọ bụ akụrụngwa mmalite. Hụ Tebụl 2 maka ụdị ụdị dị iche iche, wee wụsa ịwụ mmiri n'ime mgbapụta mmiri si na mmiri mgbapụta mmiri iji mee ka mmanu rọba dị na mgbapụta ahụ, wee debe mgbapụta ọkụ eletrik nke nwere ike ime ka ọ kwụ ọtọ na kwụ ọtọ. Malite (ọ bụghị ihe karịrị otu sekọnd) ma lelee ma ntụzịaka stereị ọ dabara na akara stereị. Ọ bụrụ na ọ bụghị, gbanwee njikọ abụọ ọ bụla nke eriri ụzọ atọ. Mgbe ahụ wụnye nzacha ma kwadebe ka ị gbadaa n'olulu mmiri ahụ. Ọ bụrụ na ejiri ya n'oge pụrụ iche (dịka ọwa mmiri, ọwa mmiri, osimiri, ọdọ mmiri, ọdọ mmiri, wdg), mgbapụta ọkụ eletrik ga-agbanyerịrị nke ọma.
(2) Akụrụngwa na akụrụngwa ntinye:
1. Otu ụzọ na-ebuli agbụ maka ihe karịrị tọn abụọ.
2. A tripod nwere ogologo kwụ ọtọ na-erughị mita anọ.
3. Ụdọ abụọ kwụgidere (ụdọ waya) nke nwere ike ibu ibu ihe karịrị otu ton (nwere ike ibu ibu nke nfuli mmiri zuru ezu).
4. Wụnye ụzọ abụọ nke clamps (splints).
5. Wrenches, hammers, screwdrivers, eletriki ngwaọrụ na ngwá, wdg.
(3) Nwụnye mgbapụta ọkụ eletrik:
1. E gosipụtara eserese nrụnye nke mgbapụta ọkụ eletrik submersible na eserese 2. A na-egosipụta akụkụ ntinye kpọmkwem na Tebụl 3 "Ndepụta nke nrụnye akụkụ nke mgbapụta ọkụ eletrik".
2. Enwere ike ibunye nfuli eletriki na-ekpuchi isi na isi ihe na-erughị mita 30 ozugbo n'ime olulu mmiri site na iji ụdọ na eriri waya ma ọ bụ eriri hemp ndị ọzọ nwere ike iburu igwe zuru oke nke igwe dum, ọkpọkọ mmiri na mmiri na ọkpọkọ.
3. Nfuli nke nwere isi ihe karịrị mita 30 na-eji ọkpọkọ ígwè, na usoro ntinye bụ nke a:
① Jiri ihe nkedo iji kpoo njedebe elu nke akụkụ mgbapụta mmiri (a na-ejikọta moto na mmiri mgbapụta n'oge a), bulite ya na agbụ nke nghọta, ma jiri nwayọọ nwayọọ kechie ya n'ime olulu mmiri ruo mgbe ịtinye ihe nkedo na isi mmiri ma wepụ ya. nghọta yinye.
② Jiri ụzọ mkpị ọzọ kụchie ọkpọkọ, were yinye kwụgidere 15 cm pụọ na flange, wee wetuo ya nwayọ. N'etiti ọkpọkọ flange na mgbapụta flange Tinye ihe mgbochi rọba n'ebe ma mee ka ọkpọkọ ahụ sie ike ma gbapụta ya nke ọma na bolts, mkpụrụ na mmiri mmiri.
③ Welite obere mgbapụta submersible, wepụ ihe nkedo dị na nsọtụ elu nke mgbapụta mmiri ahụ, kechie eriri ahụ nke ọma na ọkpọkọ mmiri na teepu rọba, ma jiri nwayọọ nwayọọ kechie ya ruo mgbe etinyere mkpọ ahụ n'isi olulu mmiri.
④ Jiri otu usoro ahụ kee ọkpọkọ mmiri niile n'ime olulu mmiri.
⑤ Mgbe ejikọtara eriri na-eduga na njikwa njikwa, a na-ejikọta ya na ọkụ ọkụ nke atọ.
(4) Ihe ị ga-ahụ n'oge echichi:
1. Ọ bụrụ na achọpụtara ihe mgbagwoju anya n'oge usoro mgbapụta ahụ, tụgharịa ma ọ bụ dọrọ ọkpọkọ mmiri iji merie ebe nkwụsị. Ọ bụrụ na usoro dị iche iche ka na-arụ ọrụ, biko Amanyela mgbapụta ahụ ka ọ ghara imebi mgbapụta ọkụ eletrik na olulu mmiri.
2. N'oge echichi, a ga-etinye ihe mkpuchi rọba na flange nke ọkpọkọ ọ bụla ma mee ka ọ sie ike.
3. Mgbe a na-agbanye mmiri mmiri n'ime olulu mmiri ahụ, a ga-etinye ya n'etiti ọkpọkọ nke ọma iji gbochie mgbapụta ahụ na-agba ọsọ megide mgbidi olulu mmiri ruo ogologo oge, na-eme ka mgbapụta ahụ na-ama jijiji na moto na-ekpochapụ ma gbaa ọkụ. .
4. Kpebie omimi nke mgbapụta mmiri na ala nke olulu mmiri dịka ájá na-asọ asọ na ọnọdụ silt nke olulu mmiri ahụ. Eliela mgbapụta n'ime apịtị. Ebe dị anya site na mgbapụta mmiri na ala nke olulu mmiri n'ozuzu ọ bụghị ihe na-erughị mita 3 (lee foto 2).
5. Ihe omimi ntinye mmiri nke mgbapụta mmiri kwesịrị ịbụ ihe na-erughị 1-1.5 mita site na mmiri dị ike na ọnụ mmiri ntinye mmiri (lee foto 2). Ma ọ bụghị ya, a ga-emebi bearings mgbapụta mmiri n'ụzọ dị mfe.
6. Ebuli nke mgbapụta mmiri enweghị ike ịdị ala. Ma ọ bụghị ya, ekwesịrị itinye valvụ ọnụ ụzọ ámá na pipeline mmiri nke ọma iji chịkwaa mgbapụta mgbapụta na ebe a na-agbapụta agbapụta iji gbochie moto ahụ ka ọ ghara ibufe ma gbaa ọkụ n'ihi nnukwu ọnụọgụ mmiri.
7. Mgbe mgbapụta mmiri na-agba ọsọ, mmepụta mmiri kwesịrị ịdị na-aga n'ihu na ọbụna, nke dị ugbu a kwesịrị ịdị na-eguzosi ike (n'okpuru ọnọdụ ọrụ a kwadoro, n'ozuzu ọ dịghị ihe karịrị 10% nke akara ugbu a), na e kwesịghị inwe mkpọtụ ma ọ bụ mkpọtụ. Ọ bụrụ na enwere ihe na-adịghị mma, a ga-akwụsị igwe ahụ iji chọpụta ihe kpatara ya ma kpochapụ ya.
8. Mgbe ị na-etinye ya, ṅaa ntị na ntọala nke waya mgbanaka moto (lee foto 2). Mgbe ọkpọkọ mmiri bụ ọkpọkọ ígwè, dupụta ya site na mkpọchi olulu mmiri; mgbe ọkpọkọ mmiri bụ ọkpọkọ plastik, duga ya site na akara ala nke mgbapụta eletrik.
- 1.After the submersible pump is installed, check the insulation resistance and three-phase conduction from the switch again, check whether the instrument and the connection of the start equipment are wrong, if there is no problem, the trial machine can be started, and observe whether the indicator readings of the instrument exceed the rated voltage and current specified on the nameplate after the start, and observe whether the pump has noise and vibration phenomenon. If everything is normal, it can be put into operation.
- 2. After the first operation of the pump for four hours, the motor should be shut down to test the thermal insulation resistance quickly, and its value should not be less than 0.5 megaohm.
- 3. After the pump is shut down, it should be started after five minutes to prevent the water column in the pipe from being completely reflowed and causing excessive motor current and burnout.
- 4.After the pump is running normally, in order to prolong its service life, it is necessary to check the power supply voltage, running current and insulation resistance regularly to see if they are normal.If the following conditions are found, the equipment should be shut down immediately to troubleshoot.
- (1)Under the rated working conditions, the current exceeds 20% of the rated value.
- (2)The dynamic water level drops to the inlet part, resulting in intermittent water discharge.
- (3)The submersible pump vibrates violently or emits noisy noise.
- (4)The power supply voltage is lower than 340 volts.
- (5)A fuse is burned out.
- (6)The water pipe is damaged.
- (7)The thermal insulation resistance of the motor to the ground is less than 0.5 megaohm.
- These inspections will help to ensure the normal operation of the pump, improve its reliability and stability, so as to ensure its durability and service life.
- 5.unit disassembly:
- - untie cable rope, remove the pipeline part, remove the wire plate.
- - sụọ ngọngọ mmiri, tinye mmiri n'ime ụlọ moto.
- - remove the filter, loose the fixed screw on the coupling fixed motor shaft.
- - screw down the bolt connected with the motor at the inlet junction, separate the pump and the motor (pay attention to the unit cushion when separating, prevent the bending of the pump shaft)
- - pump disassembly sequence is: (see figure 1) inlet junction, impeller, guide housing, impeller...... check valve body, when removing the impeller, use special tools to loosen the conical sleeve of the fixed impeller first, avoid bending the pump shaft and each part in the disassembly process.
- - motor disassembly process is: (see figure 1) place the motor on the platform, remove the nut, base, shaft head lock nut, thrust plate, key, lower guide bearing seat, double head bolt from the bottom of the motor in turn, then take out the rotor (pay attention not to damage the wire package) and finally remove the connecting section and upper guide bearing seat.
- - unit assembly: Before assembly, the rust and dirt of the parts should be cleaned, and the mating surfaces and fasteners should be coated with sealant. Then they should be assembled in the reverse order of disassembly (the up and down momentum of the motor shaft is about 1 mm after assembly). After assembly, the coupling should be flexible, and then the filter screen test machine.
- 6.The submersible pump should be dismantled and repaired according to Article 5 for each operation year, or less than one year, but the submersible time has reached two years, and the worn parts should be replaced.
1, wepụta mmiri n'ime oghere moto (karịsịa n'oge oyi iji gbochie moto ahụ ka ọ ghara ịnwụ), ma kee eriri ahụ nke ọma.
2, na-echekwa n'ime ụlọ na-enweghị ihe ndị na-emebi emebi na gas, na-enwe okpomọkụ n'okpuru 40 Celsius.
3, ogologo oge ojiji kwesịrị ịṅa ntị na nchara mgbochi nke submersible nfuli.
- impeller
- Ogwe aka
- Roba aro ogwe aka
-
mgbanaka akara
01 Mmiri olulu mmiri miri emi
02 Mmiri mmiri dị elu
03 mmiri mmiri ugwu
04 ụlọ elu mmiri
05 Agricultural ogbugba mmiri n'ubi
06 ogbugba mmiri n'ubi
07 oriri mmiri osimiri
08 mmiri ụlọ