D'Benotzung vun Waasser ënnerdaach submersible Motor, Rotor wear-resistant durchgang sleeve an durchgang Schub disc Design.Méi haltbar wéi (Ueleg taucht winding, Rotor Lagermotor), méi ëmweltfrëndlech.Keng Ueleg Leckage nom Ausfall vun der Pompel, keng Pollutioun vun gutt Waasser, sécherer use.The impeller Grupp benotzt héich Stäerkt Anti-Sand wear-resistent géint PC Composite Polymer Materialien, nei dräi-zweedimensional hydraulesch Design, schwiewend Impeller, Keramik Anti-Sand Struktur Verschleißbeständegkeet, voll Lift, grousse flow.Water-gefëllt Motor kann Déift vun 300 Meter daucht.
This product is a three-phase AC 380V (tolerance ± 5%), 50HZ (tolerance ± 1%) power supply system, designed for strict water quality requirements. The product is suitable for water temperature not higher than 20 °C, solid impurities content (mass ratio) is not greater than 0.01%, PH value (pH) between 6.5-8.5, hydrogen sulfide content is not greater than 1.5mg/L, chloride ion content is not greater than 400mg/L environment. This product is equipped with a closed or water-filled wet structure motor, before use must be submersible motor inner cavity filled with clean water to prevent false full, and then tighten the water and air bolts, otherwise not to use. The submersible pump must be completely immersed in water to work, penetration depth shall not exceed 70 meters, the distance from the bottom of the pump to the bottom of the well shall not be less than 3 meters. In addition, the well water flow should meet the continuous operation requirements of the submersible pump, the water output of the submersible pump should be controlled at 0.7-1.2 times the rated flow. When used, the well must be vertical, and the submersible pump can not be used horizontally or dumped, only vertical installation. To ensure safety, the submersible pump must match the cable according to the requirements and be equipped with external overload protection device, and it is strictly prohibited to conduct no-load test on the pump without water. This product is an ideal choice for providing high quality water source, and can be widely used in various industrial and civil water processing fields.
105QJ series water-filled stainless steel deep well pump |
|||||
Modell |
Flow m³/h |
Kapp (m) |
Motor Muecht (KW) |
Eenheet Duerchmiesser (mm) |
diameter (mm) |
105QJ2-230/36 |
2 |
230 |
4kw vun |
103 |
105 |
105QJ2-300/50 |
300 |
5,5kw eng |
|||
105QJ2-390/65 |
390 |
7 ,5kw |
|||
Spezifikatioune vun 105QJ4-50/10 |
4 |
50 |
1,1kw eng |
103 |
105 |
Spezifikatioune vun 105QJ4-60/12 |
60 |
1,5kw eng |
|||
105QJ4-80/16 |
80 |
2,2kw eng |
|||
Spezifikatioune vun 105QJ4-100/20 |
100 |
3 kw |
|||
105QJ4-140/28 |
140 |
4kw vun |
|||
105QJ4-200/40 Ubidder |
200 |
5,5kw eng |
|||
105QJ4-275/55 |
275 |
7 ,5kw |
|||
Spezifikatioune vun 105QJ6-35/10 |
6 |
35 |
1,1kw eng |
103 |
105 |
Spezifikatioune vun 105QJ6-40/12 |
40 |
1,5kw eng |
|||
105QJ6-60/16 |
60 |
2,2kw eng |
|||
105QJ6-75/20 |
75 |
3 kw |
|||
105QJ6-105/28 |
105 |
4kw vun |
|||
105QJ6-140/40 Ubidder |
140 |
5,5kw eng |
|||
105QJ6-192/55 |
192 |
7 ,5kw |
|||
Spezifikatioune vun 105QJ8-25/5 |
8 |
25 |
1,1kw eng |
103 |
105 |
Spezifikatioune vun 105QJ8-40/8 |
40 |
1,5kw eng |
|||
105QJ8-55/11 |
55 |
2,2kw eng |
|||
105QJ8-75/15 |
75 |
3 kw |
|||
105QJ8-95/19 |
95 |
4kw vun |
|||
105QJ8-125/25 |
125 |
5,5kw eng |
|||
Spezifikatioune vun 105QJ8-160/32 |
160 |
7 ,5kw |
|||
Spezifikatioune vun 105QJ10-20/5 |
10 |
20 |
1,1kw eng |
103 |
105 |
Spezifikatioune vun 105QJ10-30/8 |
30 |
1,5kw eng |
|||
105QJ10-40/11 |
40 |
2,2kw eng |
|||
105QJ10-55/15 |
55 |
3 kw |
|||
105QJ10-75/19 |
75 |
4kw vun |
|||
105QJ10-90/25 |
90 |
5,5kw eng |
|||
Spezifikatioune vun 105QJ10-120/32 |
120 |
7 ,5kw |
|||
105QJ16-22/9 |
16 |
22 |
2,2kw eng |
103 |
105 |
105QJ16-28/12 |
28 |
3 kw |
|||
105QJ16-35/15 |
35 |
4kw vun |
|||
Spezifikatioune vun 105QJ16-50/20 |
50 |
5,5kw eng |
|||
105QJ16-68/27 |
68 |
7 ,5kw |
130QJ series water-filled stainless steel deep well pump |
|||||
Modell |
Flow m³/h |
Kapp (m) |
Motor Muecht (KW) |
Eenheet Duerchmiesser (mm) |
diameter (mm) |
Spezifikatioune vun 130QJ10-60/7 |
10 |
60 |
1,5kw eng |
130 |
135 |
130QJ10-80/12 |
80 |
2,2kw eng |
|||
130QJ10-100/15 |
100 |
3 kw |
|||
130QJ10-130/20 |
130 |
4kw vun |
|||
130QJ10-160/25 |
160 |
5,5kw eng |
|||
130QJ10-220/32 |
220 |
7 ,5kw |
|||
130QJ10-250/38 |
250 |
9 ,2kw |
|||
130QJ10-300/42 |
300 |
11 kw |
|||
130QJ10-350/50 |
350 |
13 kw |
|||
130QJ10-400/57 |
400 |
15 kw |
|||
130QJ10-450/64 |
450 |
18,5 kW |
|||
130QJ10-500/70 |
500 |
22 kw |
|||
130QJ15-40/5 |
15 |
40 |
1,5kw eng |
130 |
135 |
Spezifikatioune vun 130QJ15-50/7 |
50 |
2,2kw eng |
|||
130QJ15-60/10 |
60 |
3 kw |
|||
130QJ15-80/12 |
80 |
4kw vun |
|||
130QJ15-105/15 |
105 |
5,5kw eng |
|||
130QJ15-150/22 |
150 |
7 ,5kw |
|||
130QJ15-170/25 |
170 |
9 ,2kw |
|||
130QJ15-200/28 |
200 |
11 kw |
|||
130QJ15-240/34 |
240 |
13 kw |
|||
130QJ15-280/40 |
280 |
15 kw |
|||
130QJ15-300/42 |
300 |
18,5 kW |
|||
130QJ15-336/48 |
336 |
18,5 kW |
|||
130QJ15-350/50 |
350 |
22 kw |
|||
130QJ15-400/56 |
400 |
22 kw |
130QJ series water-filled stainless steel deep well pump |
|||||
Modell |
Flow m³/h |
Kapp (m) |
Motor Muecht (KW) |
Eenheet Duerchmiesser (mm) |
diameter (mm) |
130QJ20-22/3 |
20 |
30 |
2,2kw eng |
130 |
135 |
130QJ20-30/5 |
42 |
3 kw |
|||
Spezifikatioune vun 130QJ20-42/6 |
54 |
4kw vun |
|||
Spezifikatioune vun 130QJ20-52/8 |
65 |
5,5kw eng |
|||
130QJ20-72/11 |
85 |
7 ,5kw |
|||
130QJ20-90/14 |
110 |
9 ,2kw |
|||
130QJ20-105/16 |
128 |
11 kw |
|||
130QJ20-130/19 |
145 |
13 kw |
|||
130QJ20-150/22 |
164 |
15 kw |
|||
130QJ20-182/27 |
182 |
18,5 kW |
|||
130QJ20-208/31 |
208 |
22 kw |
|||
130QJ20-240/35 |
240 |
25 kw |
|||
130QJ20-286/42 |
286 |
30 kw |
|||
130QJ25-35/6 |
25 |
35 |
3 kw |
130 |
135 |
Spezifikatioune vun 130QJ25-40/7 |
40 |
4kw vun |
|||
130QJ25-52/9 |
52 |
5,5kw eng |
|||
130QJ25-70/12 |
70 |
7 ,5kw |
|||
130QJ25-85/15 |
85 |
9 ,2kw |
|||
130QJ25-105/18 |
105 |
11 kw |
|||
130QJ25-120/21 |
120 |
13 kw |
|||
130QJ25-140/24 |
140 |
15 kw |
150QJ series water-filled stainless steel deep well pump |
|||||
Modell |
Flow m³/h |
Kapp (m) |
Motor Muecht (KW) |
Eenheet Duerchmiesser (mm) |
diameter (mm) |
Spezifikatioune vun 150QJ12-40/3 |
12 |
40 |
2,2kw eng |
143 |
150 |
150QJ12-55/5 |
55 |
3 kw |
|||
150QJ12-80/7 |
80 |
4kw vun |
|||
150QJ12-107/9 |
107 |
5,5kw eng |
|||
150QJ12-142/11 |
142 |
7 ,5kw |
|||
150QJ12-175/14 |
175 |
9 ,2kw |
|||
150QJ12-200/16 |
200 |
11 kw |
|||
150QJ12-242/19 |
242 |
13 kw |
|||
150QJ12-268/21 |
268 |
15 kw |
|||
150QJ12-293/23 |
293 |
18,5 kW |
|||
Spezifikatioune vun 150QJ20-28/3 |
20 |
28 |
3 kw |
143 |
150 |
150QJ20-48/5 Ubidder |
48 |
4kw vun |
|||
150QJ20-70/7 |
70 |
5,5kw eng |
|||
150QJ20-90/9 |
90 |
7 ,5kw |
|||
150QJ20-107/11 |
107 |
9 ,2kw |
|||
150QJ20-135/14 |
135 |
11 kw |
|||
150QJ20-155/16 |
155 |
13 kw |
|||
150QJ20-175/18 |
175 |
15 kw |
|||
150QJ20-195/20 |
195 |
18,5 kW |
|||
150QJ20-220/22 |
220 |
18,5 kW |
|||
150QJ20-235/25 |
235 |
22 kw |
|||
150QJ20-255/28 |
255 |
25 kw |
150QJ series water-filled stainless steel deep well pump |
|||||
Modell |
Flow m³/h |
Kapp (m) |
Motor Muecht (KW) |
Eenheet Duerchmiesser (mm) |
diameter (mm) |
150QJ45-18/2 Ubidder |
45 |
18 |
4kW eng |
143 |
150 |
150QJ45-28/3 Ubidder |
28 |
5,5 kW an |
|||
150QJ45-46/5 Präis |
46 |
7,5 kW an |
|||
150QJ45-57/6 |
57 |
9,2 kW |
|||
150QJ45-65/7 Präis |
65 |
11 kW |
|||
150QJ45-75/8 |
75 |
13 kW |
|||
150QJ45-90/10 |
90 |
15 kW an |
|||
150QJ45-108/12 |
108 |
18,5 kW |
|||
150QJ45-125/14 |
125 |
22 kW |
|||
150QJ45-145/16 |
145 |
25 kW |
|||
150QJ45-168/18 |
168 |
30 kW an |
|||
Spezifikatioune vun 150QJ32-20/2 |
32 |
20 |
3 kw |
143 |
150 |
150QJ32-30/3 Ubidder |
30 |
4kw vun |
|||
150QJ32-43/4 Ubidder |
43 |
5,5kw eng |
|||
150QJ32-60/5 Präis |
60 |
7 ,5kw |
|||
150QJ32-65/6 |
65 |
7 ,5kw |
|||
150QJ32-75/7 |
75 |
9 ,2kw |
|||
150QJ32-85/8 |
85 |
11 kw |
|||
Spezifikatioune vun 150QJ32-100/9 |
100 |
13 kw |
|||
Spezifikatioune vun 150QJ32-110/10 |
110 |
15 kw |
|||
150QJ32-118/11 |
118 |
18,5 kW |
|||
150QJ32-140/13 |
140 |
18,5 kW |
|||
150QJ32-155/15 |
155 |
22 kw |
|||
150QJ32-185/18 |
185 |
25 kw |
|||
150QJ32-215/21 |
215 |
30 kw |
This kind of well submersible pump is a clean water pump. It is strictly prohibited to dig new wells and extract sediments and turbid water. The voltage grade of the well pump is 380/50HZ. The submersible motor with other voltage grades needs to be customized. Underground cables must be waterproof cables and must be equipped with starting equipment, such as distribution box, etc. The starting equipment should have common comprehensive motor protection functions, such as short circuit overload protection, phase loss protection, undervoltage protection, grounding protection and idling protection, etc., to prevent timely tripping when abnormal conditions occur. The pump must be reliably grounded during installation and use, and it is strictly prohibited to push and pull the switch when the hands and feet are wet. The power supply must be cut off before installation and maintenance of the pump. The place where the pump is used must be set up with obvious "anti-electric shock" marks. Before going down the well or installation, the motor must be filled with distilled water or non-corrosive clean cold water in the internal chamber, and the drain bolt must be fastened. When testing the pump on the ground, water must be injected into the pump chamber to lubricate the rubber bearings. The instantaneous start time shall not exceed one second to check whether the direction is correct, and the direction is the same as the direction indicator. When the pump is erected, pay attention to safety to prevent injury from tilting. Strictly in accordance with the provisions of the pump lift and flow range of use, to avoid the pump in the low flow when the large flow or in the high lift appears in the large pull, resulting in extreme wear of thrust bearings and other components, the motor overload and burn. After the pump into the well, the insulation resistance between the motor and the ground should be measured, not less than 100MΩ. After the start, regular observation of voltage and current, and check whether the motor winding insulation meets the requirements of the provisions. If the location temperature of the pump storage is below the freezing point, the water in the motor cavity should be drained, so as not to damage the motor in winter low temperature freezing.
- 1.Submersible Pompel Installatioun ass komplett, kontrolléiert d'Isolatiounsresistenz an d'Dreiphaseleitung vum Schalter, kontrolléiert d'Instrument a fänkt d'Ausrüstungsverbindungsfehler un, wann et kee Problem ass, kann de Prozess starten, nom Start vum Instrument Beweist d'Liesungen, ob méi wéi d'Nomenplack virgesinn bewäert Spannung a Stroum, beobachtet de Pompelgeräischer a Schwéngungsphenomen, alles ass normal kann a Betrib geholl ginn.
- 2.D'éischt Operatioun vun der Pompel fir véier Stonnen, soll séier ofgeschalt ginn Test d'thermesch Isolatioun Resistenz vum Motor, de Wäert soll net manner wéi 0,5 megaohm ginn.
- 3.No der Pompel Ausschaltung, sollt no engem Intervall vu fënnef Minutten gestart ginn, fir ze vermeiden datt d'Waasserkolonn an der Päif net komplett Reflux verursaacht duerch exzessiv Motorstroum a Burnout.
- 4.No der Pompel an normal Operatioun, fir säi Liewensdauer ze verlängeren, d'Versuergungsspannung ze kontrolléieren, d'Aarbechtsstroum an d'Isolatiounsresistenz ass normal, wann d'folgend Situatioun fonnt gëtt, sollt d'Problembehandlung direkt ausschalten.
1 am bewäertten Zoustand ass de Stroum méi wéi 20%.
2 dynamesch Waasserniveau an d'Waasserintaksektioun, wat intermittéiert Waasser verursaacht.
3 Tauchpompel schwéier Schwéngung oder Kaméidi.
4 Versuergungsspannung ass manner wéi 340 Volt.
5 Fusioun verbrannt eng Phase.
6 Waasser Päif Schued.
7 Motor zu der thermesch Isolatioun Resistenz ass manner wéi 0,5 megaohm.
- 5.Unit Demontage:
1 Kabel Tether untie, ewechzehuelen de Pipeline Deel, ewechzehuelen der Drot Plack.
2 d'Waasserschrauwen erofschrauwen, d'Waasser an d'Motorkammer setzen.
3 Huelt de Filter erof, loosst déi fix Schraube op der Kupplung fir de Motorwellen ze fixéieren.
4 Schrauwen de Bolzen erof, deen d'Waasserinntakssektioun mam Motor verbënnt, a trennt d'Pompel vum Motor (opgepasst op d'Eenheetskëssen beim Trennen, fir d'Biege vum Pompelschacht ze vermeiden)
5 der Demontage Sequenz vun der Pompel ass: (kuckt Figur 1) Waasser Inlet Sektioun, Impeller, Diversioun Shell, Impeller ...... Kontrollventil Kierper, wann Dir de Impeller erofhuelen, benotzt speziell Tools fir d'konesch Hülse vum fixen ze loosen Impeller als éischt, a vermeit d'Pompelwelle beim Ofbau ze béien an ze briechen.
6 den Demontageprozess vum Motor ass: (kuckt Figur 1) setzt de Motor op der Plattform, a läscht d'Nëss, d'Basis, d'Schafkopfschlossmutter, d'Schubplack, d'Schlëssel, den ënneschte Guidelagersitz an d'Doppelkopbolt vun ënnen vun de Motor ofwiesselnd, an dann de Rotor huelen eraus (opgepasst net der Drot Pak ze Schued) an ewechzehuelen endlech der Verbindung Rubrik an ieweschte Guide Lager Sëtz.
7 Eenheet Assemblée: virun der Assemblée, de Rost an Dreck vun den Deeler soll gebotzt ginn, an der mating Uewerfläch an fasteners mat Dichtstoff Beschichtete ginn, an dann am Géigendeel Uerdnung vun Demontage versammelt (de Motor Aarsch bewegt op an erof no Montage fir ongeféier eent) Millimeter), no der Montage soll d'Kupplung flexibel sinn, an dann d'Filterbildschierm Testmaschinn. Submersible Pompelen ginn aus der Brunn fir Ofbau an Ënnerhalt no Artikel 5 no engem Joer vun Operatioun, oder manner wéi engem Joer vun Operatioun, mä zwee Joer vun Tauchen Zäit, an d'verschratt Deeler ersat ginn.
Dëst Produkt ass eng submersible elektresch Pompel mat excellent Leeschtung. Säin eenzegaartegen Design ass gëeegent fir a verschiddene Occasiounen ze benotzen. Egal ob et ass fir ze verhënneren datt de Motor am Wanter afréiert oder fir Rust ze vermeiden wann et net laang benotzt gëtt, dës Tauchtpompel kann Är Bedierfnesser fir Ausrüstung Ënnerhalt treffen. Et ass einfach ze bedreiwen a bequem ze pflegen. Follegt just d'Schrëtt an der Handbuch fir korrekt Ënnerhalt a Lagerung, wat d'Liewensdauer vum Produkt effektiv verlängeren kann. Kritt dës Tauchtpompel elo a maacht Är Aarbecht méi glat a méi effizient!
01 Déift gutt Waasser ofgeroden
02 Héichwaasserversuergung
03 Bierg Waasser Fourniture
04 Tuerm Waasser
05 Landwirtschaftlech Bewässerung
06 Gaart Bewässerung
07 Floss Waasser ofgeroden
08 Hauswaasser