Semi-vlekvrye staal gesplete reeks diepputpomp

Onderneem OEM-verwerking! Volgens gebruikersvereistes, ontwerp en vervaardiging van verskillende soorte spesiale vereistes van nie-standaard dompelmotor en pomp. Die produkimplementeringstandaarde: GB/T2816-2014 "put dompelpomp", GB/T2818-2014 "goed dompelbare asynchrone motor". WhatsApp: 17855846335
PDF DOWNLOAD
Besonderhede
Merkers
 
Produk Oorsig

Die gebruik van water ondergedompelde dompelmotor, rotor slytvaste legeringshuls en legeringsdrukskyfontwerp. Meer duursaam as (olie ondergedompelde wikkeling, rotor dra motor), meer omgewingsvriendelik.Geen olie lekkasie na die mislukking van die pomp, geen besoedeling van putwater, veiliger gebruik. Die waaiergroep gebruik hoë sterkte anti-sand slytvaste PC saamgestelde polimeer materiale, nuwe driedimensionele hidrouliese ontwerp, drywende waaier, keramiek anti-sand struktuur slytasie weerstand, volle hysbak, groot vloei. Water gevulde motor kan diepte van 300 meter duik.

 

 
Gebruiksvoorwaardes

This product is a three-phase AC 380V (tolerance ± 5%), 50HZ (tolerance ± 1%) power supply system, designed for strict water quality requirements. The product is suitable for water temperature not higher than 20 °C, solid impurities content (mass ratio) is not greater than 0.01%, PH value (pH) between 6.5-8.5, hydrogen sulfide content is not greater than 1.5mg/L, chloride ion content is not greater than 400mg/L environment. This product is equipped with a closed or water-filled wet structure motor, before use must be submersible motor inner cavity filled with clean water to prevent false full, and then tighten the water and air bolts, otherwise not to use. The submersible pump must be completely immersed in water to work, penetration depth shall not exceed 70 meters, the distance from the bottom of the pump to the bottom of the well shall not be less than 3 meters. In addition, the well water flow should meet the continuous operation requirements of the submersible pump, the water output of the submersible pump should be controlled at 0.7-1.2 times the rated flow. When used, the well must be vertical, and the submersible pump can not be used horizontally or dumped, only vertical installation. To ensure safety, the submersible pump must match the cable according to the requirements and be equipped with external overload protection device, and it is strictly prohibited to conduct no-load test on the pump without water. This product is an ideal choice for providing high quality water source, and can be widely used in various industrial and civil water processing fields.

 

 
Model Betekenis

Semi-Stainless Steel Split Series Deep Well Pump

 
Gedeeltelike Modelverwysing

105QJ series water-filled stainless steel deep well pump

Model

Vloei

m³/h

Kop

(m)

Motor

Krag

(KW)

Eenheid

deursnee

(mm)

diameter (mm)

105QJ2-230/36

2

230

4kw

103

105

105QJ2-300/50

300

5.5kw

105QJ2-390/65

390

7.5kw

105QJ4-50/10

4

50

1.1kw

103

105

105QJ4-60/12

60

1.5kw

105QJ4-80/16

80

2.2kw

105QJ4-100/20

100

3 kw

105QJ4-140/28

140

4kw

105QJ4-200/40

200

5.5kw

105QJ4-275/55

275

7.5kw

105QJ6-35/10

6

35

1.1kw

103

105

105QJ6-40/12

40

1.5kw

105QJ6-60/16

60

2.2kw

105QJ6-75/20

75

3 kw

105QJ6-105/28

105

4kw

105QJ6-140/40

140

5.5kw

105QJ6-192/55

192

7.5kw

105QJ8-25/5

8

25

1.1kw

103

105

105QJ8-40/8

40

1.5kw

105QJ8-55/11

55

2.2kw

105QJ8-75/15

75

3 kw

105QJ8-95/19

95

4kw

105QJ8-125/25

125

5.5kw

105QJ8-160/32

160

7.5kw

105QJ10-20/5

10

20

1.1kw

103

105

105QJ10-30/8

30

1.5kw

105QJ10-40/11

40

2.2kw

105QJ10-55/15

55

3 kw

105QJ10-75/19

75

4kw

105QJ10-90/25

90

5.5kw

105QJ10-120/32

120

7.5kw

105QJ16-22/9

16

22

2.2kw

103

105

105QJ16-28/12

28

3 kw

105QJ16-35/15

35

4kw

105QJ16-50/20

50

5.5kw

105QJ16-68/27

68

7.5kw

 

130QJ series water-filled stainless steel deep well pump

Model

Vloei

m³/h

Kop

(m)

Motor

Krag

(KW)

Eenheid

deursnee

(mm)

diameter (mm)

130QJ10-60/7

10

60

1.5kw

130

135

130QJ10-80/12

80

2.2kw

130QJ10-100/15

100

3 kw

130QJ10-130/20

130

4kw

130QJ10-160/25

160

5.5kw

130QJ10-220/32

220

7.5kw

130QJ10-250/38

250

9.2kw

130QJ10-300/42

300

11 kw

130QJ10-350/50

350

13kw

130QJ10-400/57

400

15 kw

130QJ10-450/64

450

18.5kw

130QJ10-500/70

500

22kw

130QJ15-40/5

15

40

1.5kw

130

135

130QJ15-50/7

50

2.2kw

130QJ15-60/10

60

3 kw

130QJ15-80/12

80

4kw

130QJ15-105/15

105

5.5kw

130QJ15-150/22

150

7.5kw

130QJ15-170/25

170

9.2kw

130QJ15-200/28

200

11 kw

130QJ15-240/34

240

13kw

130QJ15-280/40

280

15 kw

130QJ15-300/42

300

18.5kw

130QJ15-336/48

336

18.5kw

130QJ15-350/50

350

22kw

130QJ15-400/56

400

22kw

 

130QJ series water-filled stainless steel deep well pump

 

Model

Vloei

m³/h

Kop

(m)

Motor

Krag

(KW)

Eenheid

deursnee

(mm)

diameter (mm)

130QJ20-22/3

20

30

2.2kw

130

135

130QJ20-30/5

42

3 kw

130QJ20-42/6

54

4kw

130QJ20-52/8

65

5.5kw

130QJ20-72/11

85

7.5kw

130QJ20-90/14

110

9.2kw

130QJ20-105/16

128

11 kw

130QJ20-130/19

145

13kw

130QJ20-150/22

164

15 kw

130QJ20-182/27

182

18.5kw

130QJ20-208/31

208

22kw

130QJ20-240/35

240

25 kw

130QJ20-286/42

286

30kw

130QJ25-35/6

25

35

3 kw

130

135

130QJ25-40/7

40

4kw

130QJ25-52/9

52

5.5kw

130QJ25-70/12

70

7.5kw

130QJ25-85/15

85

9.2kw

130QJ25-105/18

105

11 kw

130QJ25-120/21

120

13kw

130QJ25-140/24

140

15 kw

 

150QJ series water-filled stainless steel deep well pump

Model

Vloei

m³/h

Kop

(m)

Motor

Krag

(KW)

Eenheid

deursnee

(mm)

diameter (mm)

150QJ12-40/3

12

40

2.2kw

143

150

150QJ12-55/5

55

3 kw

150QJ12-80/7

80

4kw

150QJ12-107/9

107

5.5kw

150QJ12-142/11

142

7.5kw

150QJ12-175/14

175

9.2kw

150QJ12-200/16

200

11 kw

150QJ12-242/19

242

13kw

150QJ12-268/21

268

15 kw

150QJ12-293/23

293

18.5kw

150QJ20-28/3

20

28

3 kw

143

150

150QJ20-48/5

48

4kw

150QJ20-70/7

70

5.5kw

150QJ20-90/9

90

7.5kw

150QJ20-107/11

107

9.2kw

150QJ20-135/14

135

11 kw

150QJ20-155/16

155

13kw

150QJ20-175/18

175

15 kw

150QJ20-195/20

195

18.5kw

150QJ20-220/22

220

18.5kw

150QJ20-235/25

235

22kw

150QJ20-255/28

255

25 kw

 

150QJ series water-filled stainless steel deep well pump

Model

Vloei

m³/h

Kop

(m)

Motor

Krag

(KW)

Eenheid

deursnee

(mm)

diameter (mm)

150QJ45-18/2

45

18

4KW

143

150

150QJ45-28/3

28

5.5KW

150QJ45-46/5

46

7.5KW

150QJ45-57/6

57

9.2KW

150QJ45-65/7

65

11KW

150QJ45-75/8

75

13KW

150QJ45-90/10

90

15KW

150QJ45-108/12

108

18.5KW

150QJ45-125/14

125

22KW

150QJ45-145/16

145

25KW

150QJ45-168/18

168

30KW

150QJ32-20/2

32

20

3 kw

143

150

150QJ32-30/3

30

4kw

150QJ32-43/4

43

5.5kw

150QJ32-60/5

60

7.5kw

150QJ32-65/6

65

7.5kw

150QJ32-75/7

75

9.2kw

150QJ32-85/8

85

11 kw

150QJ32-100/9

100

13kw

150QJ32-110/10

110

15 kw

150QJ32-118/11

118

18.5kw

150QJ32-140/13

140

18.5kw

150QJ32-155/15

155

22kw

150QJ32-185/18

185

25 kw

150QJ32-215/21

215

30kw

 

 

 
Veiligheidsmaatreëls

 This kind of well submersible pump is a clean water pump. It is strictly prohibited to dig new wells and extract sediments and turbid water. The voltage grade of the well pump is 380/50HZ. The submersible motor with other voltage grades needs to be customized. Underground cables must be waterproof cables and must be equipped with starting equipment, such as distribution box, etc. The starting equipment should have common comprehensive motor protection functions, such as short circuit overload protection, phase loss protection, undervoltage protection, grounding protection and idling protection, etc., to prevent timely tripping when abnormal conditions occur. The pump must be reliably grounded during installation and use, and it is strictly prohibited to push and pull the switch when the hands and feet are wet. The power supply must be cut off before installation and maintenance of the pump. The place where the pump is used must be set up with obvious "anti-electric shock" marks. Before going down the well or installation, the motor must be filled with distilled water or non-corrosive clean cold water in the internal chamber, and the drain bolt must be fastened. When testing the pump on the ground, water must be injected into the pump chamber to lubricate the rubber bearings. The instantaneous start time shall not exceed one second to check whether the direction is correct, and the direction is the same as the direction indicator. When the pump is erected, pay attention to safety to prevent injury from tilting. Strictly in accordance with the provisions of the pump lift and flow range of use, to avoid the pump in the low flow when the large flow or in the high lift appears in the large pull, resulting in extreme wear of thrust bearings and other components, the motor overload and burn. After the pump into the well, the insulation resistance between the motor and the ground should be measured, not less than 100MΩ. After the start, regular observation of voltage and current, and check whether the motor winding insulation meets the requirements of the provisions. If the location temperature of the pump storage is below the freezing point, the water in the motor cavity should be drained, so as not to damage the motor in winter low temperature freezing.

 

 
Onderhoud en Onderhoud
  1. 1. Dompelpompinstallasie is voltooi, herkontroleer die isolasieweerstand en driefasegeleiding vanaf die skakelaar, kontroleer die instrument en begin die toerustingverbindingsfout, as daar geen probleem is nie, kan die proef begin, na die begin van die instrument wat lesings aandui of meer as die naamplaat gestipuleer nominale spanning en stroom, let op die pomp geraas en vibrasie verskynsel, alles is normaal kan in werking gestel word.
  2. 2.The first operation of the pump for four hours, should be shut down quickly test the thermal insulation resistance of the motor, the value should not be less than 0.5 megaohm.
  3. 3.After the pump shutdown, should be started after an interval of five minutes, to prevent the water column in the pipe has not completely reflux caused by excessive motor current and burnout.
  4. 4.After the pump into normal operation, in order to prolong its service life, to check the supply voltage, working current and insulation resistance is normal, if found the following situation, should immediately shut down troubleshooting.
  5.  

 1 in the rated condition, the current is more than 20%.

 2 dynamic water level to the water inlet section, causing intermittent water.

 3 submersible pump severe vibration or noise.

 4 supply voltage is lower than 340 volts.

 5 fuse burned out a phase.

 6 water pipe damage.

 7 motor to the thermal insulation resistance is less than 0.5 megaohm.

 

  1. 5. Eenheid demontage:

 1 untie cable tether, remove the pipeline part, remove the wire plate.

 2 skroef die waterbout af, sit die water in die motorkamer.

 3 verwyder die filter, los die vaste skroef op die koppeling los om die motoras vas te maak.

 4 screw down the bolt connecting the water inlet section with the motor, and separate the pump from the motor (pay attention to the unit cushion when separating, to prevent the bending of the pump shaft)

 5 the disassembly sequence of the pump is: (see figure 1) water inlet section, impeller, diversion shell, impeller...... check valve body, when removing the impeller, use special tools to loosen the conical sleeve of the fixed impeller first, and avoid bending and bruising the pump shaft in the process of disassembly.

 6 die demontageproses van die motor is: (sien figuur 1) plaas die motor op die platform, en verwyder die moere, basis, askop-sluitmoer, stootplaat, sleutel, onderste gidslaer-sitplek en dubbelkopbout van die onderkant van die motor op sy beurt, en haal dan die rotor uit (let op om nie die draadpakket te beskadig nie) en verwyder laastens die verbindingsgedeelte en boonste gidslagersitplek.

 7 unit assembly: before assembly, the rust and dirt of the parts should be cleaned, and the mating surface and fasteners coated with sealant, and then assembled in the opposite order of disassembly (the motor shaft moves up and down after assembly for about one millimeter), after assembly, the coupling should be flexible, and then the filter screen test machine. Submersible pumps shall be taken out of the well for dismantling and maintenance according to Article 5 after a year of operation, or less than a year of operation but two years of diving time, and the worn parts shall be replaced.

 

 
Berging en bewaring

This product is a submersible electric pump with excellent performance. Its unique design is suitable for use in various occasions. Whether it is to prevent the motor from freezing in winter or to prevent rust when it is not used for a long time, this submersible electric pump can meet your needs for equipment maintenance. It is simple to operate and convenient to maintain. Just follow the steps in the manual for correct maintenance and storage, which can effectively prolong the service life of the product. Get this submersible electric pump now and make your work smoother and more efficient!

 

 
Toepassingsscenario's

01 Diep put water inname

02 Hoë watervoorsiening

03 bergwatervoorsiening 

04 toring water

05 Landboubesproeiing

06 tuinbesproeiing

07 rivier water inname

08 huishoudelike water

 

As jy belangstel in ons produkte, kan jy kies om jou inligting hier te los, en ons sal binnekort met jou in verbinding tree.


Skryf jou boodskap hier en stuur dit vir ons

As jy belangstel in ons produkte, kan jy kies om jou inligting hier te los, en ons sal binnekort met jou in verbinding tree.


afAfrikaans