O uso de motor submersível imerso em água, luva de liga resistente ao desgaste do rotor e design de disco de impulso de liga. Mais durável do que (enrolamento imerso em óleo, motor de rolamento do rotor), mais ecologicamente correto. água de poço, uso mais seguro. O grupo de impulsor usando materiais de polímero composto de PC anti-areia de alta resistência e resistentes ao desgaste, novo design hidráulico tridimensional, impulsor flutuante, resistência ao desgaste de estrutura cerâmica anti-areia, elevação total, grande fluxo. o motor pode mergulhar em profundidade de 300 metros.
This product is a three-phase AC 380V (tolerance ± 5%), 50HZ (tolerance ± 1%) power supply system, designed for strict water quality requirements. The product is suitable for water temperature not higher than 20 °C, solid impurities content (mass ratio) is not greater than 0.01%, PH value (pH) between 6.5-8.5, hydrogen sulfide content is not greater than 1.5mg/L, chloride ion content is not greater than 400mg/L environment. This product is equipped with a closed or water-filled wet structure motor, before use must be submersible motor inner cavity filled with clean water to prevent false full, and then tighten the water and air bolts, otherwise not to use. The submersible pump must be completely immersed in water to work, penetration depth shall not exceed 70 meters, the distance from the bottom of the pump to the bottom of the well shall not be less than 3 meters. In addition, the well water flow should meet the continuous operation requirements of the submersible pump, the water output of the submersible pump should be controlled at 0.7-1.2 times the rated flow. When used, the well must be vertical, and the submersible pump can not be used horizontally or dumped, only vertical installation. To ensure safety, the submersible pump must match the cable according to the requirements and be equipped with external overload protection device, and it is strictly prohibited to conduct no-load test on the pump without water. This product is an ideal choice for providing high quality water source, and can be widely used in various industrial and civil water processing fields.
105QJ series water-filled stainless steel deep well pump |
|||||
Modelo |
Fluxo m³/h |
Cabeça (m) |
Motor Poder (KW) |
Unidade diâmetro (milímetros) |
diameter (mm) |
105QJ2-230/36 |
2 |
230 |
4kw |
103 |
105 |
105QJ2-300/50 |
300 |
5,5 kW |
|||
105QJ2-390/65 |
390 |
7,5 kW |
|||
105QJ4-50/10 |
4 |
50 |
1,1 kW |
103 |
105 |
105QJ4-60/12 |
60 |
1,5 kW |
|||
105QJ4-80/16 |
80 |
2,2 kW |
|||
105QJ4-100/20 |
100 |
3kw |
|||
105QJ4-140/28 |
140 |
4kw |
|||
105QJ4-200/40 |
200 |
5,5 kW |
|||
105QJ4-275/55 |
275 |
7,5 kW |
|||
105QJ6-35/10 |
6 |
35 |
1,1 kW |
103 |
105 |
105QJ6-40/12 |
40 |
1,5 kW |
|||
105QJ6-60/16 |
60 |
2,2 kW |
|||
105QJ6-75/20 |
75 |
3kw |
|||
105QJ6-105/28 |
105 |
4kw |
|||
105QJ6-140/40 |
140 |
5,5 kW |
|||
105QJ6-192/55 |
192 |
7,5 kW |
|||
105QJ8-25/5 |
8 |
25 |
1,1 kW |
103 |
105 |
105QJ8-40/8 |
40 |
1,5 kW |
|||
105QJ8-55/11 |
55 |
2,2 kW |
|||
105QJ8-75/15 |
75 |
3kw |
|||
105QJ8-95/19 |
95 |
4kw |
|||
105QJ8-125/25 |
125 |
5,5 kW |
|||
105QJ8-160/32 |
160 |
7,5 kW |
|||
105QJ10-20/5 |
10 |
20 |
1,1 kW |
103 |
105 |
105QJ10-30/8 |
30 |
1,5 kW |
|||
105QJ10-40/11 |
40 |
2,2 kW |
|||
105QJ10-55/15 |
55 |
3kw |
|||
105QJ10-75/19 |
75 |
4kw |
|||
105QJ10-90/25 |
90 |
5,5 kW |
|||
105QJ10-120/32 |
120 |
7,5 kW |
|||
105QJ16-22/9 |
16 |
22 |
2,2 kW |
103 |
105 |
105QJ16-28/12 |
28 |
3kw |
|||
105QJ16-35/15 |
35 |
4kw |
|||
105QJ16-50/20 |
50 |
5,5 kW |
|||
105QJ16-68/27 |
68 |
7,5 kW |
130QJ series water-filled stainless steel deep well pump |
|||||
Modelo |
Fluxo m³/h |
Cabeça (m) |
Motor Poder (KW) |
Unidade diâmetro (milímetros) |
diameter (mm) |
130QJ10-60/7 |
10 |
60 |
1,5 kW |
130 |
135 |
130QJ10-80/12 |
80 |
2,2 kW |
|||
130QJ10-100/15 |
100 |
3kw |
|||
130QJ10-130/20 |
130 |
4kw |
|||
130QJ10-160/25 |
160 |
5,5 kW |
|||
130QJ10-220/32 |
220 |
7,5 kW |
|||
130QJ10-250/38 |
250 |
9,2 kW |
|||
130QJ10-300/42 |
300 |
11 kW |
|||
130QJ10-350/50 |
350 |
13 kW |
|||
130QJ10-400/57 |
400 |
15 kW |
|||
130QJ10-450/64 |
450 |
18,5 kW |
|||
130QJ10-500/70 |
500 |
22 kW |
|||
130QJ15-40/5 |
15 |
40 |
1,5 kW |
130 |
135 |
130QJ15-50/7 |
50 |
2,2 kW |
|||
130QJ15-60/10 |
60 |
3kw |
|||
130QJ15-80/12 |
80 |
4kw |
|||
130QJ15-105/15 |
105 |
5,5 kW |
|||
130QJ15-150/22 |
150 |
7,5 kW |
|||
130QJ15-170/25 |
170 |
9,2 kW |
|||
130QJ15-200/28 |
200 |
11 kW |
|||
130QJ15-240/34 |
240 |
13 kW |
|||
130QJ15-280/40 |
280 |
15 kW |
|||
130QJ15-300/42 |
300 |
18,5 kW |
|||
130QJ15-336/48 |
336 |
18,5 kW |
|||
130QJ15-350/50 |
350 |
22 kW |
|||
130QJ15-400/56 |
400 |
22 kW |
130QJ series water-filled stainless steel deep well pump |
|||||
Modelo |
Fluxo m³/h |
Cabeça (m) |
Motor Poder (KW) |
Unidade diâmetro (milímetros) |
diameter (mm) |
130QJ20-22/3 |
20 |
30 |
2,2 kW |
130 |
135 |
130QJ20-30/5 |
42 |
3kw |
|||
130QJ20-42/6 |
54 |
4kw |
|||
130QJ20-52/8 |
65 |
5,5 kW |
|||
130QJ20-72/11 |
85 |
7,5 kW |
|||
130QJ20-90/14 |
110 |
9,2 kW |
|||
130QJ20-105/16 |
128 |
11 kW |
|||
130QJ20-130/19 |
145 |
13 kW |
|||
130QJ20-150/22 |
164 |
15 kW |
|||
130QJ20-182/27 |
182 |
18,5 kW |
|||
130QJ20-208/31 |
208 |
22 kW |
|||
130QJ20-240/35 |
240 |
25 kW |
|||
130QJ20-286/42 |
286 |
30 kW |
|||
130QJ25-35/6 |
25 |
35 |
3kw |
130 |
135 |
130QJ25-40/7 |
40 |
4kw |
|||
130QJ25-52/9 |
52 |
5,5 kW |
|||
130QJ25-70/12 |
70 |
7,5 kW |
|||
130QJ25-85/15 |
85 |
9,2 kW |
|||
130QJ25-105/18 |
105 |
11 kW |
|||
130QJ25-120/21 |
120 |
13 kW |
|||
130QJ25-140/24 |
140 |
15 kW |
150QJ series water-filled stainless steel deep well pump |
|||||
Modelo |
Fluxo m³/h |
Cabeça (m) |
Motor Poder (KW) |
Unidade diâmetro (milímetros) |
diameter (mm) |
150QJ12-40/3 |
12 |
40 |
2,2 kW |
143 |
150 |
150QJ12-55/5 |
55 |
3kw |
|||
150QJ12-80/7 |
80 |
4kw |
|||
150QJ12-107/9 |
107 |
5,5 kW |
|||
150QJ12-142/11 |
142 |
7,5 kW |
|||
150QJ12-175/14 |
175 |
9,2 kW |
|||
150QJ12-200/16 |
200 |
11 kW |
|||
150QJ12-242/19 |
242 |
13 kW |
|||
150QJ12-268/21 |
268 |
15 kW |
|||
150QJ12-293/23 |
293 |
18,5 kW |
|||
150QJ20-28/3 |
20 |
28 |
3kw |
143 |
150 |
150QJ20-48/5 |
48 |
4kw |
|||
150QJ20-70/7 |
70 |
5,5 kW |
|||
150QJ20-90/9 |
90 |
7,5 kW |
|||
150QJ20-107/11 |
107 |
9,2 kW |
|||
150QJ20-135/14 |
135 |
11 kW |
|||
150QJ20-155/16 |
155 |
13 kW |
|||
150QJ20-175/18 |
175 |
15 kW |
|||
150QJ20-195/20 |
195 |
18,5 kW |
|||
150QJ20-220/22 |
220 |
18,5 kW |
|||
150QJ20-235/25 |
235 |
22 kW |
|||
150QJ20-255/28 |
255 |
25 kW |
150QJ series water-filled stainless steel deep well pump |
|||||
Modelo |
Fluxo m³/h |
Cabeça (m) |
Motor Poder (KW) |
Unidade diâmetro (milímetros) |
diameter (mm) |
150QJ45-18/2 |
45 |
18 |
4KW |
143 |
150 |
150QJ45-28/3 |
28 |
5,5 kW |
|||
150QJ45-46/5 |
46 |
7,5 kW |
|||
150QJ45-57/6 |
57 |
9,2 kW |
|||
150QJ45-65/7 |
65 |
11KW |
|||
150QJ45-75/8 |
75 |
13 kW |
|||
150QJ45-90/10 |
90 |
15KW |
|||
150QJ45-108/12 |
108 |
18,5 kW |
|||
150QJ45-125/14 |
125 |
22 kW |
|||
150QJ45-145/16 |
145 |
25 kW |
|||
150QJ45-168/18 |
168 |
30KW |
|||
150QJ32-20/2 |
32 |
20 |
3kw |
143 |
150 |
150QJ32-30/3 |
30 |
4kw |
|||
150QJ32-43/4 |
43 |
5,5 kW |
|||
150QJ32-60/5 |
60 |
7,5 kW |
|||
150QJ32-65/6 |
65 |
7,5 kW |
|||
150QJ32-75/7 |
75 |
9,2 kW |
|||
150QJ32-85/8 |
85 |
11 kW |
|||
150QJ32-100/9 |
100 |
13 kW |
|||
150QJ32-110/10 |
110 |
15 kW |
|||
150QJ32-118/11 |
118 |
18,5 kW |
|||
150QJ32-140/13 |
140 |
18,5 kW |
|||
150QJ32-155/15 |
155 |
22 kW |
|||
150QJ32-185/18 |
185 |
25 kW |
|||
150QJ32-215/21 |
215 |
30 kW |
This kind of well submersible pump is a clean water pump. It is strictly prohibited to dig new wells and extract sediments and turbid water. The voltage grade of the well pump is 380/50HZ. The submersible motor with other voltage grades needs to be customized. Underground cables must be waterproof cables and must be equipped with starting equipment, such as distribution box, etc. The starting equipment should have common comprehensive motor protection functions, such as short circuit overload protection, phase loss protection, undervoltage protection, grounding protection and idling protection, etc., to prevent timely tripping when abnormal conditions occur. The pump must be reliably grounded during installation and use, and it is strictly prohibited to push and pull the switch when the hands and feet are wet. The power supply must be cut off before installation and maintenance of the pump. The place where the pump is used must be set up with obvious "anti-electric shock" marks. Before going down the well or installation, the motor must be filled with distilled water or non-corrosive clean cold water in the internal chamber, and the drain bolt must be fastened. When testing the pump on the ground, water must be injected into the pump chamber to lubricate the rubber bearings. The instantaneous start time shall not exceed one second to check whether the direction is correct, and the direction is the same as the direction indicator. When the pump is erected, pay attention to safety to prevent injury from tilting. Strictly in accordance with the provisions of the pump lift and flow range of use, to avoid the pump in the low flow when the large flow or in the high lift appears in the large pull, resulting in extreme wear of thrust bearings and other components, the motor overload and burn. After the pump into the well, the insulation resistance between the motor and the ground should be measured, not less than 100MΩ. After the start, regular observation of voltage and current, and check whether the motor winding insulation meets the requirements of the provisions. If the location temperature of the pump storage is below the freezing point, the water in the motor cavity should be drained, so as not to damage the motor in winter low temperature freezing.
- 1. A instalação da bomba submersível está concluída, verifique novamente a resistência de isolamento e a condução trifásica do interruptor, verifique o instrumento e inicie o erro de conexão do equipamento, se não houver problema, pode iniciar o teste, após o início do instrumento indicando leituras se mais do que a tensão e corrente nominais estipuladas na placa de identificação, observe o ruído da bomba e o fenômeno de vibração, tudo está normal pode ser colocado em operação.
- 2.A primeira operação da bomba em quatro horas, deve ser desligada rapidamente para testar a resistência de isolamento térmico do motor, o valor não deve ser inferior a 0,5 megaohm.
- 3.Após o desligamento da bomba, deve-se ligá-la após um intervalo de cinco minutos, para evitar que a coluna de água na tubulação não tenha refluxo completo causado por corrente excessiva do motor e desgaste.
- 4. Após a bomba entrar em operação normal, a fim de prolongar sua vida útil, para verificar se a tensão de alimentação, a corrente de trabalho e a resistência de isolamento estão normais, se for encontrada a seguinte situação, deve-se desligar imediatamente a solução de problemas.
1 na condição nominal, a corrente é superior a 20%.
2 nível de água dinâmico para a seção de entrada de água, causando água intermitente.
3 bomba submersível vibração ou ruído severo.
4 a tensão de alimentação é inferior a 340 volts.
5 fusível queimou uma fase.
6 danos na tubulação de água.
7 motor para a resistência de isolamento térmico é inferior a 0,5 megaohm.
- 5. Desmontagem da unidade:
1 desamarre o cabo, remova a parte da tubulação, remova a placa de fio.
2 aperte o parafuso de água, coloque a água na câmara do motor.
3 remova o filtro, afrouxe o parafuso fixo no acoplamento para fixar o eixo do motor.
4 aparafuse o parafuso que conecta a seção de entrada de água ao motor e separe a bomba do motor (preste atenção à almofada da unidade ao separar, para evitar a flexão do eixo da bomba)
5 a sequência de desmontagem da bomba é: (ver figura 1) seção de entrada de água, impulsor, casco de desvio, impulsor...... corpo da válvula de retenção, ao remover o impulsor, use ferramentas especiais para afrouxar a luva cônica do fixo impulsor primeiro e evite dobrar e machucar o eixo da bomba no processo de desmontagem.
6 o processo de desmontagem do motor é: (ver figura 1) coloque o motor na plataforma e remova as porcas, base, porca de travamento da cabeça do eixo, placa de encosto, chaveta, assento do rolamento guia inferior e parafuso de cabeça dupla da parte inferior do o motor por sua vez e, em seguida, retire o rotor (preste atenção para não danificar o pacote de fios) e, finalmente, remova a seção de conexão e o assento do rolamento guia superior.
7 montagem da unidade: antes da montagem, a ferrugem e a sujeira das peças devem ser limpas, e a superfície de contato e os fixadores devem ser revestidos com selante e, em seguida, montados na ordem oposta da desmontagem (o eixo do motor se move para cima e para baixo após a montagem por cerca de um milímetro), após a montagem, o acoplamento deve ser flexível e, em seguida, a máquina de teste de tela de filtro. As bombas submersíveis deverão ser retiradas do poço para desmontagem e manutenção de acordo com o Artigo 5 após um ano de operação, ou menos de um ano de operação, mas dois anos de tempo de mergulho, e as peças desgastadas deverão ser substituídas.
Este produto é uma bomba elétrica submersível com excelente desempenho. Seu design exclusivo é adequado para uso em diversas ocasiões. Seja para evitar que o motor congele no inverno ou para evitar ferrugem quando não for utilizado por muito tempo, esta bomba elétrica submersível pode atender às suas necessidades de manutenção de equipamentos. É simples de operar e fácil de manter. Basta seguir os passos do manual para correta manutenção e armazenamento, o que pode efetivamente prolongar a vida útil do produto. Adquira já esta bomba elétrica submersível e torne seu trabalho mais tranquilo e eficiente!
01 Tomada de água de poço profundo
02 Abastecimento de água em arranha-céus
03 abastecimento de água na montanha
04 torre de água
05 Irrigação agrícola
06 irrigação de jardim
07 captação de água do rio
08 água doméstica