125QJB Deep Well Submersible Pump

Pangani OEM processing! Malinga ndi zofunikira za ogwiritsa ntchito, kupanga ndi kupanga mitundu yosiyanasiyana ya zofunikira zapadera zamagalimoto osakhazikika a submersible ndi pampu. Miyezo yogwiritsira ntchito mankhwala: GB/T2816-2014 "pampu yabwino kwambiri", GB/T2818-2014 "motor submersible asynchronous motor". WhatsApp: 17855846335
PDF DOWNLOAD
Tsatanetsatane
Tags
 
Zowonetsa Zamalonda

Frequency conversion winding design, ensure the motor in 1HZ-50HZ long-term stable conversion operation. Energy saving, longer service life.

 

 
Kagwiritsidwe Ntchito

1, magetsi: magawo atatu AC 380V (kulekerera + / - 5%), 50HZ (kulekerera + / - 1%).

2, khalidwe la madzi:

(1) water temperature is not higher than 20 °C;

(2) zonyansa zolimba (chiŵerengero cha misa) sichiposa 0.01%;

(3) PH mtengo (pH) 6.5-8.5;

(4) hydrogen sulfide zili zosaposa 1.5mg/L;

(5) chloride ion zili ndi 400mg/L.

3, galimoto watsekedwa kapena wodzazidwa madzi chonyowa dongosolo, musanagwiritse ntchito submersible galimoto patsekeke ayenera kukhala wodzaza ndi madzi oyera, kuteteza zabodza zonse, ndiyeno kumangitsa jekeseni madzi, mabawuti mpweya kumasulidwa, mwinamwake osaloledwa ntchito.

4, pampu ya submersible iyenera kumizidwa kwathunthu m'madzi, kuya kwamadzi sikuposa 70m, pansi pa mpope wa submersible kuchokera pansi pa chitsime sikuchepera 3m.

5, otaya chitsime madzi ayenera kukumana submersible mpope madzi linanena bungwe ndi ntchito mosalekeza, ndi submersible mpope linanena bungwe madzi ayenera kulamulidwa pa 0,7 - 1.2 nthawi otaya oveteredwa.

6, chitsimecho chiyenera kukhala chowongoka, pampu ya submersible singagwiritsidwe ntchito kapena kutayidwa, yongogwira ntchito yokha.

7, pampu ya submersible iyenera kugwirizanitsidwa ndi chingwe molingana ndi zofunikira, ndi chipangizo chakunja choteteza katundu. 8, mpope ndi zoletsedwa popanda madzi palibe katundu makina mayeso

 

 
Tanthauzo la Chitsanzo

125QJB Deep Well Submersible Pump

 
Partial Model Reference
Chitsanzo Kuyenda (m3/h)  Mutu
(m)
 Rotating speed(change/point)  Pampu (%)  Chotuluka
awiri
(mm)
Zokwanira bwino
awiri (mm) 
Adavoteledwa
mphamvu (KW)
Rated voltage(V) Ratedcurrent(A)  Kuchita bwino (%)  power factorcosφ  Chigawo
Kukula kwa Radial Maximu (mm)
Ndemanga
125QJ5-34 5 34 2850 53 40  125pamwamba 1.5 380 4.23 70.0 0.77 118  
125QJ5-51 51 2.2 6.03 72.0 0.77  
125QJ5-68 68 3 8.01 73.0 0.78  
125QJ5-85 85 4 10.53 74.0 0.78  
125QJ5-102 102 5.5 14.1 75.0 0.79  
125QJ5-119 119 5.5 14.1 75.0 0.79  
125QJ10-24 10 24 2850 60 50  125pamwamba 1.5 380 4.23 70.0 0.77 118  
125QJ10-32 32 2.2 6.03 72.0 0.77  
125QJ10-48 48 3 8.01 73.0 0.78  
125QJ10-56 56 4 10.53 74.0 0.78  
125QJ10-72 72 5.5 14.1 75.0 0.79  
125QJ10-80 80 5.5 14.1 75.0 0.79  
125QJ10-104 104 7.5 19.0 76.0 0.79  
125QJ10-120 10 120 2850 60 50  125pamwamba 7.5 380 19.0 76.0 0.79 118  
125QJ10-136 136 9.2 22.7 77.0 0.8  
125QJ15-36 15 36 2850 63 50  125pamwamba 2.2 380 6.03 72.0 0.77 118  
125QJ15-39 39 3 8.01 73.0 0.78  
125QJ15-46 46 4 10.53 74.0 0.78  
125QJ15-52 52 4 10.53 74.0 0.78  
125QJ15-59 59 5.5 14.1 75.0 0.79  
125QJ15-65 65 5.5 14.1 75.0 0.79  
125QJ15-78 78 7.5 19.0 76.0 0.79  
125QJ15-91 91 7.5 19.0 76.0 0.79  
125QJ15-104 104 9.2 22.7 77.0 0.8  
125QJ20-16 20 16 2850 64 50  125pamwamba 2.2 380 6.03 72.0 0.77 118  
125QJ20-24 24 3 8.01 73.0 0.78  
125QJ20-32 32 4 10.53 74.0 0.78  
125QJ20-40 40 4 10.53 74.0 0.78  
125QJ20-48 48 5.5 14.1 75.0 0.79  
125QJ20-56 56 5.5 14.1 75.0 0.79  
125QJ20-64 64 7.5 19.0 76.0 0.79  
125QJ20-72 72 7.5 19.0 76.0 0.79  
125QJ20-80 80 9.2 22.7 77.0 0.8  
125QJ25-12 25 12 2850 64 65  125pamwamba 2.2 380 6.03 72.0 0.77 118  
125QJ25-18 18 3 8.01 73.0 0.78  
125QJ25-24 24 4 10.53 74.0 0.78  
125QJ25-30 30 4 10.53 74.0 0.78  
125QJ25-36 36 5.5 14.1 75.0 0.79  
125QJ25-48 48 7.5 19.0 76.0 0.79  
125QJ25-60 60 9.2 22.7 77.0 0.8  
125QJ32-24 32 24 2850 64 80  125pamwamba 4 380 10.53 74.0 0.78 118  
125QJ32-30 30 5.5 14.1 75.0 0.79  
125QJ32-42 42 7.5 19.0 76.0 0.79  
125QJ32-54 54 9.2 22.7 77.0 0.8  
125QJ5-240 5 240 2850   40  125pamwamba 11 380 26.28     118  
125QJ5-280 280 13 30.87      
125QJ5-320 320 15 35.62      
125QJ10-180 10 180 2850   50  125pamwamba 11 380 26.28     118  
125QJ10-210 210 13 30.87      
125QJ10-240 240 15 35.62      
125QJ15-120 15 120 2850   50  125pamwamba 11 380 26.28     118  
125QJ15-142 142 13 30.87      
125QJ15-162 162 15 35.62      
125QJ20-100 20 100 2850   50  125pamwamba 11 380 26.28     118  
125QJ20-120 120 13 30.87      
125QJ20-136 136 15 35.62      
125QJ25-82 25 82 2850   65  125pamwamba 11 380 26.28     118  
125QJ25-97 97 13 30.87      
125QJ25-110 110 15 35.62      
125QJ32-68 32 68 2850   80  125pamwamba 11 380 26.28     118  
125QJ32-80 80 13 30.87      
125QJ32-92 92 15 35.62      
125QJ40-46 40 46 2850   80  125pamwamba 11 380 26.28     118  
125QJ40-54 54 13 30.87      
125QJ40-62 62 15 35.62      
 
Chitetezo

 The well submersible pump is a pump suitable for clear water. It is strictly prohibited to dig new wells and pump out mud and sand. The voltage grade of the well pump is 380V/50HZ, and other voltage grades of the submersible motor need to be customized. Underground cables must be waterproof cables and must be equipped with starting equipment, such as distribution box, etc. The starting equipment should have common motor comprehensive protection functions, such as short circuit overload protection, phase loss protection, undervoltage protection, grounding protection and idling protection, etc. In abnormal cases, the protective device should be tripped in time. When installing and using the pump, it must be firmly grounded. It is prohibited to push and pull the switch when the hands and feet are wet. The power supply must be cut off before installing and maintaining the pump. An obvious "anti-electric shock" sign must be set up where the pump is used. Before going down the well or installing the motor, the inner cavity must be filled with distilled water or non-corrosive clean cold water, and the water injection/drainage bolts must be tightened. Fill the pump with water for ground test to lubricate the rubber bearings. The instant start time shall not exceed one second to check whether the direction is correct and consistent with the direction indication. Be sure to pay attention to safety when placing the pump upright to prevent overturning and causing injury. Strictly in accordance with the provisions of the pump lift and flow range of use, to prevent the pump flow at low lift or excessive pull at high lift, resulting in extreme wear of thrust bearings and other components, resulting in motor overload burn. After the pump into the well, the insulation resistance between the motor and the ground shall be measured, which shall not be less than 100MΩ. After the start, observe the voltage and current regularly, and check the motor winding insulation, to see if it meets the requirements; if the pump storage temperature is below the freezing point, the water in the motor cavity should be discharged, so as to avoid the water in the motor cavity freezing and damaging the motor due to low temperature.

 

 
Mau oyamba a Kapangidwe kake
The pump part is mainly composed of pump shaft,impeller,diversion shell,rubber bearing,check valve body(optional)and other components.The motor part is mainly composed of base,pressure regulating diaphragm,thrust bearing,thrust plate,lower guide bearing seat,stator,rotor,upper guide bearing seat,sand ring,water inlet section,lead cable and other components.

Zofunika zazikulu za mankhwalawa ndi:

1.The motor is a water-loaded wet submersible three-phase asynchronous motor,and the motor cavity is filled with clean water for cooling the motor and lubricating the bearing.The regulating diaphragm at the bottom of the motor is used to adjust the expansion and contraction pressure difference inside and outside the body caused by the temperature rise of the motor.
2.In order to prevent the sand particles in the well water from entering the motor,two oil seals are installed at the extension end of the motor shaft,and the sand ring is installed to form a sand prevention structure.
3.In order to prevent the pump shaft from jumping when starting,the pump shaft is connected with the motor shaft through a coupling,and the thrust bearing is installed at the bottom of the motor.
4.The lubrication of the motor and the pump bearing is water lubrication.
5.The stator winding of the motor adopts high-quality submersible motor winding wire,with excellent insulation performance.
6.The pump is designed by computer CAD,with simple structure and excellent technical performance.

125QJB Deep Well Submersible Pump

 

 
Ikani

(1) Kukonzekera musanakhazikitse:
1. Yang'anani ngati pampu ya submersible ikugwirizana ndi momwe amagwiritsidwira ntchito komanso kukula kwake komwe kwafotokozedwa m'bukuli.
2. Pogwiritsa ntchito obiect yolemetsa yokhala ndi m'mimba mwake yofanana ndi kukula kwakunja kwa pampu ya submersible, yesani ngati innneldiameter ya chitsimecho ingagwirizane ndi mpope wa submersible, ndikuyesa ngati kuya kwa chitsime kumakwaniritsa zofunikira zoikamo.

3. Yang'anani ngati chitsime chili choyera komanso ngati madzi a m'chitsime ali abwibwi. Musagwiritse ntchito pampu yamagetsi ya submersible kutsuka matope a welor mpope ndi madzi amchenga kuti mupewe kuwonongeka msanga kwa pampu yamagetsi ya submersible.

4. Yang'anani ngati malo achitsulo choyika welhead ndi oyenera komanso ngati angapirire kuchuluka kwa gawo lonse.

5. Yang'anani ngati zigawo za pampu za submersible zatha ndikuyikidwa bwino molingana ndi chithunzi cha msonkhano chomwe chili m'mabuku Chotsani chophimba cha fyuluta ndikuzungulira cholumikizira kuti muwone ngati chimasinthasintha.

6. Chotsani zowononga zamadzi ndikudzaza pabowo lamoto ndi madzi oyera, osawononga (zindikirani. Onetsetsani kuti mwasefa), ndiyeno khwimitsani chopoperapo madzi. Pambuyo pa maola 12 a jakisoni wamadzi, kukana kwa injini sikuyenera kukhala kochepera 150M Q poyesedwa ndi tebulo logwedezeka la 500V.
7. Cable joint, cut off a 120mm rubber sleeve from one end of the outgoing cable and the matching cable with an electrician's knifethen stagger the length of the three core wires in a stepped shape, peel off a 20mm copper core, scrape of the oxide layer on theoutside of the copper wire with a knife or sand cloth, and insert the two connected wire ends in palirs.

After tying the layer tightly with fine copper wire, solder it thoroughly and firmly, and sand of any. burrs on the surface. Then, forthe three joints, use polyvester insulation tape to wrap them in a semi stacked manner for three lavers. Wrap the two ends of thewrapping layer tightywith nyion thread,and then use a semi stacked method to wrap the tape for three layers. Wrap the outellayer with high-pressure insulation tape for three layers. Finally, fold the threestrands together and repeatedly wrap them for fivelayers with high-pressure tape. Each layer must be tightly tied, and the interlayer joints must be tight and fimm to prevent water frompenetrating and damaging the insulation, After wrapping, soak in water at room temperature of 20 ’c for 12 hours, and measurethe insulation resistance with a shaking table, which should not be less than 100M Ω

 

Chiwonetsero cha njira yolumikizira chingwe chili motere:

125QJB Deep Well Submersible Pump

8. Gwiritsani ntchito multimeter kuti muwone ngati mawaya a magawo atatu alumikizidwa komanso ngati kukana kwa DC kuli pafupifupi moyenera.
9. Check whether the circuit and transformer capacity are overloaded, and then connect the overload protection switch or starting equipment. See Table 2 for specific models, and then
Pour a bucket of water into the water pump from the water pump outlet to lubricate the rubber bearings in the pump, and then place the submersible electric pump upright and steady.
Start (no more than one second) and check whether the steering direction is consistent with the steering sign. If not, swap any two connectors of the three-phase cable.
Then install the filter and prepare to go down the well. If used in special occasions (such as ditches, ditches, rivers, ponds, ponds, etc.), the electric pump must be reliably grounded.

 

(2) Zida zoyika ndi zida:
1. Peyala imodzi ya unyolo wonyamulira woposa matani awiri.
2. Tripod yokhala ndi utali woyima wosachepera mamita anayi.
3. Zingwe ziwiri zolendewera (zingwe za waya) zomwe zimatha kunyamula kulemera kopitilira tani imodzi (zimatha kunyamula ma pampu athunthu amadzi).
4. Ikani zingwe ziwiri ziwiri (zolumikizira).
5. Wrenches, nyundo, screwdrivers, zida zamagetsi ndi zida, etc.

 

(3) Kuyika pampu yamagetsi:
1. Chojambula choyikapo cha pampu yamagetsi ya submersible chikuwonetsedwa mu Chithunzi 2. Miyeso yeniyeni yoyika ikuwonetsedwa mu Table 3 "Mndandanda wa Miyeso ya Kuyika kwa Pampu ya Magetsi Oyikirapo".


2. Mapampu amagetsi oyenda pansi pamadzi okhala ndi mutu wosakwana mamita 30 akhoza kukwezedwa molunjika kuchitsime pogwiritsa ntchito mapaipi ndi zingwe za waya kapena zingwe zina za hemp zomwe zimatha kunyamula kulemera kwa makina onse, mapaipi amadzi, ndi madzi mu mapaipi.

3. Mapampu okhala ndi mutu wopitilira 30 metres amagwiritsa ntchito mapaipi achitsulo, ndipo kuyika kwake kuli motere:
①Use a clamp to clamp the upper end of the water pump part (the motor and water pump have been connected at this time), lift it with a hanging chain, and slowly tie it into the well until
Put the clamp on the wellhead and remove the hanging chain.
② Use another pair of clamps to clamp a pipe, lift it with a hanging chain 15 cm away from the flange, and lower it slowly. Between pipe flange and pump flange
Put the rubber pad in place and tighten the pipe and pump evenly with bolts, nuts and spring washers.
③ Kwezani mpope wa submersible pang'ono, chotsani chotchinga chakumtunda kwa mpope wamadzi, kumangirira chingwe ku chitoliro chamadzi ndi tepi ya pulasitiki, ndikumangirira pang'onopang'ono mpaka Chingwecho chikayikidwa pachitsime.
④Gwiritsani ntchito njira yomweyo kumanga mapaipi onse amadzi pachitsime.
⑤Chingwe chotsogolera chikalumikizidwa ndi chosinthira chowongolera, chimalumikizidwa ndi gawo la magawo atatu.

 

(4) Zinthu zofunika kuziwona pakuyika:
1. If a jamming phenomenon is found during the pumping process, turn or pull the water pipe to overcome the jamming point. If various measures still do not work, please
Do not force the pump down to avoid damage to the submersible electric pump and the well.
2. Pakuyika, mphira wa rabara uyenera kuikidwa pamphepete mwa chitoliro chilichonse ndikumangirira mofanana.
3. Pamene mpope wamadzi watsitsidwa m’chitsime, uyenera kuikidwa pakati pa chitoliro cha chitsimecho kuti mpopeyo usayendetse khoma la chitsime kwa nthawi yaitali, zomwe zimapangitsa kuti pampuyo igwedezeke ndipo injini ikusesa ndi kutentha. .
4. Dziwani kuya kwa mpope wamadzi mpaka pansi pa chitsime molingana ndi mchenga woyenda komanso silt ya pachitsime. Osakwirira mpope m'matope. Mtunda wochokera pa mpope wa madzi kufika pansi pa chitsime nthawi zambiri umakhala wosachepera mamita atatu (onani chithunzi 2).
5. Kuzama kwa madzi pa mpope kuyenera kukhala kosachepera 1-1.5 metres kuchokera pamadzi amphamvu kupita kumalo olowera madzi (onani Chithunzi 2). Kupanda kutero, mayendedwe a pampu amadzi amatha kuwonongeka mosavuta.
6. Kukweza kwa mpope wamadzi sikungakhale kotsika kwambiri. Kupanda kutero, valavu ya pachipata iyenera kuyikidwa papaipi yamadzi yakuchitsime kuti muzitha kuyendetsa pampu pamalo oyendera kuti injini isalemedwe ndikuwotchedwa chifukwa cha kuchuluka kwamadzi.
7. Pamene mpope wamadzi ukuyenda, kutuluka kwa madzi kuyenera kukhala kosalekeza komanso ngakhale, komweko kuyenera kukhala kosasunthika (pansi pa malo ogwirira ntchito, nthawi zambiri osapitirira 10% ya omwe adavotera panopa), ndipo pasakhale kugwedezeka kapena phokoso. Ngati pali vuto lililonse, makinawo ayimitsidwe kuti adziwe chomwe chayambitsa ndikuchichotsa.
8. Mukayika, mvetserani kuyika kwa waya wamoto (onani Chithunzi 2). Pamene chitoliro cha madzi ndi chitoliro chachitsulo, chitsogolereni kuchokera pachitsime chachitsulo; pamene chitoliro cha madzi ndi chitoliro cha pulasitiki, chitsogolereni kuchokera kumalo oyambira pampu yamagetsi.

 

 
Kusamalira ndi Kusamalira
  • 1.Pambuyo pa pompu ya submersible yaikidwa, yang'anani kukana kwa insulation ndi kuwongolera kwa magawo atatu kuchokera ku switch kachiwiri, fufuzani ngati chida ndi kugwirizana kwa zida zoyambira ndi zolakwika, ngati palibe vuto, makina oyesera akhoza kuyambitsidwa, ndikuwona ngati zowerengera za chipangizocho zikupitilira mphamvu yamagetsi ndi zomwe zafotokozedwa pa nameplate pambuyo poyambira, ndikuwona ngati pampu ili ndi phokoso komanso kugwedezeka, ndikuyika ntchito ngati zonse zili bwino.
  • 2.Pambuyo pa ntchito yoyamba ya mpope kwa maola anayi, galimotoyo iyenera kutsekedwa kuti iyese kukana kwa kutentha kwa kutentha mofulumira, ndipo mtengo wake suyenera kukhala wosachepera 0.5 megaohm.
  • 3.Pompoyo ikatsekedwa, iyenera kuyambika pakatha mphindi zisanu kuti tsinde la madzi mu chitoliro lisamayendetsedwe kwathunthu ndikupangitsa kuti pakhale mphamvu yamagetsi komanso kutenthedwa.
  • 4.Pambuyo pake pompayo ikagwiritsidwa ntchito moyenera, kuti apititse patsogolo moyo wake wautumiki, ndikofunikira kuyang'ana ngati magetsi operekera, ogwirira ntchito pano komanso kukana kutchinjiriza kumakhala koyenera nthawi zonse. Ngati zotsatirazi zipezeka, mpopeyo uyenera kutsekedwa nthawi yomweyo kuti athetse mavuto.
  •  
  • 1 In the rated condition, the current exceeds 20%.
  • 2 Mulingo wamadzi wosunthika umatsikira kumalo olowera madzi, kupangitsa madzi apakatikati.
  • 3 Pampu ya submersible imakhala ndi kugwedezeka kwakukulu kapena phokoso.
  • 4 Mphamvu zamagetsi ndizotsika kuposa 340 volts.
  • 5 Fuse yatenthedwa.
  • 6 Paipi yoperekera madzi yawonongeka.
  • 7 The motor's thermal insulation resistance is lower than 0.5 megaohm.
  •  
  • Unit disassembly:
  • 1.Untie the cable tie, remove the pipeline part, and remove the wire plate.
  • 2.screw down the water bolt, put the water in the motor chamber.
  • 3.remove the filter, loose the fixed screw on the coupling to fix the motor shaft.
  • 4.screw down the bolt connecting the water inlet section with the motor, and separate the pump from the motor (pay attention to the unit cushion when separating, to prevent the bending of the pump shaft)
  • 5.the disassembly sequence of the pump is: (see figure 1) water inlet section, impeller, diversion shell, impeller...... check valve body, when removing the impeller, use special tools to loosen the conical sleeve of the fixed impeller first, and avoid bending and bruising the pump shaft in the process of disassembly.
  • 6.the disassembly process of the motor is: (see figure 1) place the motor on the platform, and remove the nuts, base, shaft head locking nut, thrust plate, key, lower guide bearing seat and double head bolt from the bottom of the motor in turn, and then take out the rotor (pay attention not to damage the wire package) and finally remove the connecting section and upper guide bearing seat.
  • 7.unit assembly: before assembly, the rust and dirt of the parts should be cleaned, and the mating surface and fasteners coated with sealant, and then assembled in the opposite order of disassembly (the motor shaft moves up and down after assembly for about one millimeter), after assembly, the coupling should be flexible, and then the filter screen test machine. Submersible pumps shall be taken out of the well for dismantling and maintenance according to Article 5 after a year of operation, or less than a year of operation but two years of diving time, and the worn parts shall be replaced.

 

 
Kusunga ndi Kusunga

This product is an efficient and durable submersible electric pump, suitable for a variety of environments and applications.In order to ensure the long-term use and stable performance of the product, we suggest that users pay special attention to drying the water in the motor cavity in winter to avoid freezing; in addition, the cable is coiled and tied, and properly stored in an environment without corrosive substances and gases, with a temperature below 40 °C. If the product is not used for a long time, attention should be paid to rust prevention treatment to ensure the life cycle and performance of the product.Whether for industrial use or for home use, this submersible electric pump can provide you with reliable pump service.

 

 
Kuvala Magawo
    • Impeller
    • Mtsinje wa shaft
    • Chingwe cha rabara
    •  mphete yosindikiza

 
Zochitika za Ntchito

01 Kumwa madzi a pachitsime chakuya

02 Madzi okwera kwambiri

03 madzi a m'mapiri 

04 madzi nsanja

05 Kuthirira kwaulimi

06 ulimi wothirira m'munda

07 madzi a mitsinje

08 madzi apakhomo

 

Ngati muli ndi chidwi ndi zinthu zathu, mutha kusankha kusiya zambiri zanu pano, ndipo tidzalumikizana nanu posachedwa.


Lembani uthenga wanu apa ndikutumiza kwa ife

Ngati muli ndi chidwi ndi zinthu zathu, mutha kusankha kusiya zambiri zanu pano, ndipo tidzalumikizana nanu posachedwa.


nyNorwegian