125QJB Deep Well Submersible Pump

Ṣe iṣẹ ṣiṣe OEM! Gẹgẹbi awọn ibeere olumulo, apẹrẹ ati iṣelọpọ ti ọpọlọpọ awọn oriṣi ti awọn ibeere pataki ti ọkọ ayọkẹlẹ submersible ti kii ṣe boṣewa ati fifa soke. Ọja imuse awọn ajohunše: GB/T2816-2014 "daradara submersible fifa", GB/T2818-2014 "daradara submersible asynchronous motor". WhatsApp: 17855846335
PDF DOWNLOAD
Awọn alaye
Awọn afi
 
ọja Akopọ

Frequency conversion winding design, ensure the motor in 1HZ-50HZ long-term stable conversion operation. Energy saving, longer service life.

 

 
Awọn ipo ti Lilo

1, ipese agbara: mẹta-alakoso AC 380V (ifarada +/- 5%), 50HZ (ifarada +/- 1%).

2, Didara omi:

(1) iwọn otutu omi ko ga ju 20 °C;

(2) akoonu aimọ ti o lagbara (ipin ipin) ko tobi ju 0.01%;

(3) PH iye (pH) 6.5-8.5;

(4) akoonu sulfide hydrogen ko tobi ju 1.5mg/L;

(5) akoonu ion kiloraidi ko tobi ju 400mg/L.

3, awọn motor ti wa ni pipade tabi omi-kún tutu be, ṣaaju ki o to lilo awọn submersible motor iho gbọdọ wa ni kún fun o mọ omi, lati se eke ni kikun, ati ki o Mu awọn omi abẹrẹ, air Tu boluti, bibẹkọ ti ko gba ọ laaye lati lo.

4, fifa omi inu omi gbọdọ wa ni kikun ninu omi, ijinle omiwẹ ko tobi ju 70m, isalẹ ti fifa omi ti o wa ni isalẹ ti kanga ko kere ju 3m.

5, ṣiṣan omi kanga yẹ ki o ni anfani lati pade iṣelọpọ omi fifa omi ti o wa ni abẹlẹ ati iṣẹ ti nlọ lọwọ, o yẹ ki o wa ni iṣakoso ni 0.7 - 1.2 igba sisan ti a ṣe.

6, kanga yẹ ki o wa ni titọ, fifa omi inu omi ko le ṣee lo tabi da silẹ, lilo inaro nikan.

7, awọn submersible fifa gbọdọ wa ni ibamu pẹlu okun ni ibamu si awọn ibeere, ati awọn ita apọju Idaabobo ẹrọ. 8, fifa naa ti ni idinamọ muna laisi ẹrọ idanwo fifuye omi

 

 
Itumo awoṣe

 
Apakan Awoṣe Reference
Awoṣe Sisan (m3/h)  Ori
(m)
 Rotating speed(change/point)  Omi (%)  Ijabọ
opin
(mm)
Wulo daradara
opin (mm) 
Ti won won
agbara (KW)
Rated voltage(V) Ratedcurrent(A)  Iṣiṣẹ mọto (%)  agbara ifosiwewecosφ  Ẹyọ
Iwọn Radial ti o pọju (mm)
Akiyesi
125QJ5-34 5 34 2850 53 40  125loke 1.5 380 4.23 70.0 0.77 118  
125QJ5-51 51 2.2 6.03 72.0 0.77  
125QJ5-68 68 3 8.01 73.0 0.78  
125QJ5-85 85 4 10.53 74.0 0.78  
125QJ5-102 102 5.5 14.1 75.0 0.79  
125QJ5-119 119 5.5 14.1 75.0 0.79  
125QJ10-24 10 24 2850 60 50  125loke 1.5 380 4.23 70.0 0.77 118  
125QJ10-32 32 2.2 6.03 72.0 0.77  
125QJ10-48 48 3 8.01 73.0 0.78  
125QJ10-56 56 4 10.53 74.0 0.78  
125QJ10-72 72 5.5 14.1 75.0 0.79  
125QJ10-80 80 5.5 14.1 75.0 0.79  
125QJ10-104 104 7.5 19.0 76.0 0.79  
125QJ10-120 10 120 2850 60 50  125loke 7.5 380 19.0 76.0 0.79 118  
125QJ10-136 136 9.2 22.7 77.0 0.8  
125QJ15-36 15 36 2850 63 50  125loke 2.2 380 6.03 72.0 0.77 118  
125QJ15-39 39 3 8.01 73.0 0.78  
125QJ15-46 46 4 10.53 74.0 0.78  
125QJ15-52 52 4 10.53 74.0 0.78  
125QJ15-59 59 5.5 14.1 75.0 0.79  
125QJ15-65 65 5.5 14.1 75.0 0.79  
125QJ15-78 78 7.5 19.0 76.0 0.79  
125QJ15-91 91 7.5 19.0 76.0 0.79  
125QJ15-104 104 9.2 22.7 77.0 0.8  
125QJ20-16 20 16 2850 64 50  125loke 2.2 380 6.03 72.0 0.77 118  
125QJ20-24 24 3 8.01 73.0 0.78  
125QJ20-32 32 4 10.53 74.0 0.78  
125QJ20-40 40 4 10.53 74.0 0.78  
125QJ20-48 48 5.5 14.1 75.0 0.79  
125QJ20-56 56 5.5 14.1 75.0 0.79  
125QJ20-64 64 7.5 19.0 76.0 0.79  
125QJ20-72 72 7.5 19.0 76.0 0.79  
125QJ20-80 80 9.2 22.7 77.0 0.8  
125QJ25-12 25 12 2850 64 65  125loke 2.2 380 6.03 72.0 0.77 118  
125QJ25-18 18 3 8.01 73.0 0.78  
125QJ25-24 24 4 10.53 74.0 0.78  
125QJ25-30 30 4 10.53 74.0 0.78  
125QJ25-36 36 5.5 14.1 75.0 0.79  
125QJ25-48 48 7.5 19.0 76.0 0.79  
125QJ25-60 60 9.2 22.7 77.0 0.8  
125QJ32-24 32 24 2850 64 80  125loke 4 380 10.53 74.0 0.78 118  
125QJ32-30 30 5.5 14.1 75.0 0.79  
125QJ32-42 42 7.5 19.0 76.0 0.79  
125QJ32-54 54 9.2 22.7 77.0 0.8  
125QJ5-240 5 240 2850   40  125loke 11 380 26.28     118  
125QJ5-280 280 13 30.87      
125QJ5-320 320 15 35.62      
125QJ10-180 10 180 2850   50  125loke 11 380 26.28     118  
125QJ10-210 210 13 30.87      
125QJ10-240 240 15 35.62      
125QJ15-120 15 120 2850   50  125loke 11 380 26.28     118  
125QJ15-142 142 13 30.87      
125QJ15-162 162 15 35.62      
125QJ20-100 20 100 2850   50  125loke 11 380 26.28     118  
125QJ20-120 120 13 30.87      
125QJ20-136 136 15 35.62      
125QJ25-82 25 82 2850   65  125loke 11 380 26.28     118  
125QJ25-97 97 13 30.87      
125QJ25-110 110 15 35.62      
125QJ32-68 32 68 2850   80  125loke 11 380 26.28     118  
125QJ32-80 80 13 30.87      
125QJ32-92 92 15 35.62      
125QJ40-46 40 46 2850   80  125loke 11 380 26.28     118  
125QJ40-54 54 13 30.87      
125QJ40-62 62 15 35.62      
 
Awọn iṣọra Aabo

 The well submersible pump is a pump suitable for clear water. It is strictly prohibited to dig new wells and pump out mud and sand. The voltage grade of the well pump is 380V/50HZ, and other voltage grades of the submersible motor need to be customized. Underground cables must be waterproof cables and must be equipped with starting equipment, such as distribution box, etc. The starting equipment should have common motor comprehensive protection functions, such as short circuit overload protection, phase loss protection, undervoltage protection, grounding protection and idling protection, etc. In abnormal cases, the protective device should be tripped in time. When installing and using the pump, it must be firmly grounded. It is prohibited to push and pull the switch when the hands and feet are wet. The power supply must be cut off before installing and maintaining the pump. An obvious "anti-electric shock" sign must be set up where the pump is used. Before going down the well or installing the motor, the inner cavity must be filled with distilled water or non-corrosive clean cold water, and the water injection/drainage bolts must be tightened. Fill the pump with water for ground test to lubricate the rubber bearings. The instant start time shall not exceed one second to check whether the direction is correct and consistent with the direction indication. Be sure to pay attention to safety when placing the pump upright to prevent overturning and causing injury. Strictly in accordance with the provisions of the pump lift and flow range of use, to prevent the pump flow at low lift or excessive pull at high lift, resulting in extreme wear of thrust bearings and other components, resulting in motor overload burn. After the pump into the well, the insulation resistance between the motor and the ground shall be measured, which shall not be less than 100MΩ. After the start, observe the voltage and current regularly, and check the motor winding insulation, to see if it meets the requirements; if the pump storage temperature is below the freezing point, the water in the motor cavity should be discharged, so as to avoid the water in the motor cavity freezing and damaging the motor due to low temperature.

 

 
Ifihan to Be
The pump part is mainly composed of pump shaft,impeller,diversion shell,rubber bearing,check valve body(optional)and other components.The motor part is mainly composed of base,pressure regulating diaphragm,thrust bearing,thrust plate,lower guide bearing seat,stator,rotor,upper guide bearing seat,sand ring,water inlet section,lead cable and other components.

Awọn ẹya akọkọ ti ọja naa pẹlu:

1.The motor is a water-loaded wet submersible three-phase asynchronous motor,and the motor cavity is filled with clean water for cooling the motor and lubricating the bearing.The regulating diaphragm at the bottom of the motor is used to adjust the expansion and contraction pressure difference inside and outside the body caused by the temperature rise of the motor.
2.In order to prevent the sand particles in the well water from entering the motor,two oil seals are installed at the extension end of the motor shaft,and the sand ring is installed to form a sand prevention structure.
3.In order to prevent the pump shaft from jumping when starting,the pump shaft is connected with the motor shaft through a coupling,and the thrust bearing is installed at the bottom of the motor.
4.The lubrication of the motor and the pump bearing is water lubrication.
5.The stator winding of the motor adopts high-quality submersible motor winding wire,with excellent insulation performance.
6.The pump is designed by computer CAD,with simple structure and excellent technical performance.

 

 
Fi sori ẹrọ

(1) Igbaradi ṣaaju fifi sori:
1. Ṣayẹwo boya fifa omi inu omi ba pade awọn ipo lilo ati iwọn ti a pato ninu itọnisọna.
2. Lilo obiect ti o wuwo pẹlu iwọn ila opin ti o dọgba si iwọn ila opin ti ita ti o pọju ti fifa fifa, wiwọn boya inneldiameter ti wellbore le ni ibamu si fifa omi ti o wa ni isalẹ, ki o si wiwọn boya ijinle kanga ni ibamu pẹlu awọn ibeere fifi sori ẹrọ.

3. Ṣayẹwo boya ibi kanga jẹ mimọ ati boya omi kanga jẹ turbid. Maṣe lo fifa ina submersible lati fọ ẹrẹ fifa welor ati omi iyanrin lati yago fun ibajẹ ti tọjọ si fifa ina submersible.

4. Ṣayẹwo boya awọn ipo ti awọn welhead fifi sori dimole jẹ dara ati boya o le withstand awọn qualty ti gbogbo kuro

5. Ṣayẹwo boya awọn paati fifa submersible ti pari ati fi sori ẹrọ daradara ni ibamu si apẹrẹ apejọ ti o wa ninu iwe afọwọkọ Yọ iboju àlẹmọ naa ki o si yi asopọ pọ lati rii boya o n yi ni irọrun

6. Unscrew omi dabaru ati ki o fillthe motor iho pẹlu mọ, ti kii ipata omi (akọsilẹ. jẹ daju lati Fil o soke), ki o si Mu awọn waterscrew. Lẹhin awọn wakati 12 ti abẹrẹ omi, idabobo idabobo ti motor ko yẹ ki o kere ju 150M Q nigbati wọn wọn pẹlu tabili gbigbọn 500V.
7. Cable joint, cut off a 120mm rubber sleeve from one end of the outgoing cable and the matching cable with an electrician's knifethen stagger the length of the three core wires in a stepped shape, peel off a 20mm copper core, scrape of the oxide layer on theoutside of the copper wire with a knife or sand cloth, and insert the two connected wire ends in palirs.

After tying the layer tightly with fine copper wire, solder it thoroughly and firmly, and sand of any. burrs on the surface. Then, forthe three joints, use polyvester insulation tape to wrap them in a semi stacked manner for three lavers. Wrap the two ends of thewrapping layer tightywith nyion thread,and then use a semi stacked method to wrap the tape for three layers. Wrap the outellayer with high-pressure insulation tape for three layers. Finally, fold the threestrands together and repeatedly wrap them for fivelayers with high-pressure tape. Each layer must be tightly tied, and the interlayer joints must be tight and fimm to prevent water frompenetrating and damaging the insulation, After wrapping, soak in water at room temperature of 20 ’c for 12 hours, and measurethe insulation resistance with a shaking table, which should not be less than 100M Ω

 

Aworan ilana onirin okun ti a so mọ jẹ bi atẹle:

8. Lo multimeter kan lati ṣayẹwo boya awọn onirin mẹta-alakoso ti wa ni ti sopọ ati boya awọn DC resistance jẹ to iwontunwonsi.
9. Check whether the circuit and transformer capacity are overloaded, and then connect the overload protection switch or starting equipment. See Table 2 for specific models, and then
Pour a bucket of water into the water pump from the water pump outlet to lubricate the rubber bearings in the pump, and then place the submersible electric pump upright and steady.
Start (no more than one second) and check whether the steering direction is consistent with the steering sign. If not, swap any two connectors of the three-phase cable.
Then install the filter and prepare to go down the well. If used in special occasions (such as ditches, ditches, rivers, ponds, ponds, etc.), the electric pump must be reliably grounded.

 

(2) Awọn ohun elo fifi sori ẹrọ ati awọn irinṣẹ:
1. Ọkan bata ti awọn ẹwọn gbigbe fun diẹ ẹ sii ju awọn toonu meji lọ.
2. A mẹta pẹlu kan inaro iga ti ko kere ju mẹrin mita.
3. Awọn okun adiye meji (awọn okun waya) ti o le jẹ iwuwo diẹ ẹ sii ju ọkan lọ (le jẹ iwuwo ti pipe pipe ti awọn fifa omi).
4. Fi sori ẹrọ meji orisii clamps (splints).
5. Wrenches, òòlù, screwdrivers, itanna irinṣẹ ati ohun elo, ati be be lo.

 

(3) Fifi sori ẹrọ fifa ẹrọ itanna:
1. Aworan fifi sori ẹrọ ti fifa ina mọnamọna submersible ti wa ni afihan ni Nọmba 2. Awọn iwọn fifi sori ẹrọ pato ni a fihan ni Table 3 "Akojọ ti Awọn Iwọn fifi sori ẹrọ ti Imudanu Imọlẹ Imọlẹ".


2. Awọn ifasoke ina mọnamọna ti o wa ni isalẹ pẹlu ori ti o kere ju 30 mita ni a le gbe soke taara sinu kanga nipa lilo awọn okun ati awọn okun waya tabi awọn okun hemp miiran ti o le ni kikun iwuwo ti gbogbo ẹrọ, awọn ọpa omi, ati omi ninu awọn paipu.

3. Awọn ifasoke pẹlu ori ti o ju 30 mita lo awọn paipu irin, ati ilana fifi sori ẹrọ jẹ bi atẹle:
①Use a clamp to clamp the upper end of the water pump part (the motor and water pump have been connected at this time), lift it with a hanging chain, and slowly tie it into the well until
Put the clamp on the wellhead and remove the hanging chain.
② Use another pair of clamps to clamp a pipe, lift it with a hanging chain 15 cm away from the flange, and lower it slowly. Between pipe flange and pump flange
Put the rubber pad in place and tighten the pipe and pump evenly with bolts, nuts and spring washers.
③ Gbe fifa omi ti o wa ni isalẹ diẹ diẹ, yọ idimu ti o wa ni opin oke ti fifa omi, di okun naa ṣinṣin si paipu omi pẹlu teepu ike kan, ki o si so o lọra titi di igba ti a fi dimu si ibi kanga.
④ Lo ọna kanna lati di gbogbo awọn paipu omi sinu kanga.
⑤ Lẹhin ti okun-jade ti a ti sopọ si iyipada iṣakoso, o ti sopọ si ipese agbara mẹta-alakoso.

 

(4) Awọn nkan lati ṣe akiyesi lakoko fifi sori ẹrọ:
1. If a jamming phenomenon is found during the pumping process, turn or pull the water pipe to overcome the jamming point. If various measures still do not work, please
Do not force the pump down to avoid damage to the submersible electric pump and the well.
2. Lakoko fifi sori ẹrọ, paadi rọba yẹ ki o gbe ni flange ti paipu kọọkan ati ki o ni wiwọ paapaa.
3. Nigbati fifa omi ba ti wa ni isalẹ sinu kanga, o yẹ ki o gbe si arin paipu kanga naa lati ṣe idiwọ fifa soke lati ṣiṣẹ lodi si odi kanga fun igba pipẹ, ti o mu ki fifa soke lati gbọn ati pe ọkọ ayọkẹlẹ lati gba ati sisun. .
4. Ṣe ipinnu ijinle ti fifa omi si isalẹ ti kanga gẹgẹbi iyanrin ti nṣan ati awọn ipo silt ti kanga. Ma ṣe sin fifa soke sinu ẹrẹ. Ijinna lati fifa omi si isalẹ ti kanga ni gbogbogbo ko kere ju awọn mita 3 (wo Nọmba 2).
5. Ijinle titẹsi omi ti fifa omi yẹ ki o jẹ ko kere ju awọn mita 1-1.5 lati ipele omi ti o ni agbara si oju omi ti nwọle (wo Nọmba 2). Bibẹẹkọ, awọn bearings fifa omi le ni irọrun bajẹ.
6. Gbigbe ti fifa omi ko le jẹ kekere ju. Bibẹẹkọ, àtọwọdá ẹnu-ọna nilo lati fi sori ẹrọ lori opo gigun ti omi kanga lati ṣakoso ṣiṣan fifa ni aaye ṣiṣan ti o ni iwọn lati ṣe idiwọ mọto lati ni apọju ati sisun nitori awọn iwọn sisan nla.
7. Nigbati fifa omi ba n ṣiṣẹ, ṣiṣan omi yẹ ki o wa ni ilọsiwaju ati paapaa, lọwọlọwọ yẹ ki o wa ni iduroṣinṣin (labẹ awọn ipo iṣẹ ti a ṣe ayẹwo, ni gbogbo igba ko ju 10% ti iṣiro lọwọlọwọ), ati pe ko yẹ ki o jẹ gbigbọn tabi ariwo. Ti aiṣedeede eyikeyi ba wa, ẹrọ naa yẹ ki o da duro lati wa idi ti o fa ati imukuro rẹ.
8. Nigbati fifi sori, san ifojusi si awọn eto ti awọn motor grounding waya (wo Figure 2). Nigbati paipu omi jẹ paipu irin, darí rẹ lati dimole kanga; nigbati paipu omi jẹ paipu ike kan, darí rẹ lati aami ilẹ ti fifa ina.

 

 
Itọju ati Itọju
  • 1.After the submersible pump ti fi sori ẹrọ, ṣayẹwo awọn idabobo idabobo ati mẹta-ipele ifọnọhan lati awọn yipada lẹẹkansi, ṣayẹwo boya awọn irinse ati awọn asopọ ti awọn ibere ẹrọ ni o wa ti ko tọ, ti o ba ti nibẹ ni ko si isoro, awọn iwadii ẹrọ le ti wa ni bere, ati ṣe akiyesi boya awọn kika Atọka ti ohun elo naa kọja foliteji ti o ni iwọn ati lọwọlọwọ pato lori apẹrẹ orukọ lẹhin ibẹrẹ, ki o ṣe akiyesi boya fifa soke ni ariwo ati lasan gbigbọn, ati fi sinu iṣẹ ti ohun gbogbo ba jẹ deede.
  • 2.After akọkọ isẹ ti fifa soke fun wakati mẹrin, awọn motor yẹ ki o wa ni pipade lati se idanwo awọn gbona idabobo resistance ni kiakia, ati awọn oniwe-iye ko yẹ ki o jẹ kere ju 0,5 megaohm.
  • 3.After awọn fifa soke ti wa ni pipade, o yẹ ki o bẹrẹ lẹhin iṣẹju marun lati dena iwe-omi ti o wa ninu paipu lati jẹ atunṣe patapata ati ki o fa ki o pọju lọwọlọwọ motor ati sisun.
  • 4.After ti a fi fifa soke sinu iṣẹ deede, lati le pẹ igbesi aye iṣẹ rẹ, o jẹ dandan lati ṣayẹwo boya foliteji ipese, ṣiṣe lọwọlọwọ ati idabobo idabobo jẹ deede deede. Ti awọn ipo atẹle ba wa, fifa soke yẹ ki o wa ni pipade lẹsẹkẹsẹ lati yanju.
  •  
  • 1 In the rated condition, the current exceeds 20%.
  • 2 Ipele omi ti o ni agbara ṣubu si apakan iwọle omi, ti o nfa omi lainidii.
  • 3 Awọn fifa omi inu omi ni gbigbọn nla tabi ariwo.
  • 4 Foliteji ipese jẹ kekere ju 340 volts.
  • 5 Fiusi kan ti jona.
  • 6 Paipu ipese omi ti bajẹ.
  • 7 The motor's thermal insulation resistance is lower than 0.5 megaohm.
  •  
  • Unit disassembly:
  • 1.Untie the cable tie, remove the pipeline part, and remove the wire plate.
  • 2.screw down the water bolt, put the water in the motor chamber.
  • 3.remove the filter, loose the fixed screw on the coupling to fix the motor shaft.
  • 4.screw down the bolt connecting the water inlet section with the motor, and separate the pump from the motor (pay attention to the unit cushion when separating, to prevent the bending of the pump shaft)
  • 5.the disassembly sequence of the pump is: (see figure 1) water inlet section, impeller, diversion shell, impeller...... check valve body, when removing the impeller, use special tools to loosen the conical sleeve of the fixed impeller first, and avoid bending and bruising the pump shaft in the process of disassembly.
  • 6.the disassembly process of the motor is: (see figure 1) place the motor on the platform, and remove the nuts, base, shaft head locking nut, thrust plate, key, lower guide bearing seat and double head bolt from the bottom of the motor in turn, and then take out the rotor (pay attention not to damage the wire package) and finally remove the connecting section and upper guide bearing seat.
  • 7.unit assembly: before assembly, the rust and dirt of the parts should be cleaned, and the mating surface and fasteners coated with sealant, and then assembled in the opposite order of disassembly (the motor shaft moves up and down after assembly for about one millimeter), after assembly, the coupling should be flexible, and then the filter screen test machine. Submersible pumps shall be taken out of the well for dismantling and maintenance according to Article 5 after a year of operation, or less than a year of operation but two years of diving time, and the worn parts shall be replaced.

 

 
Ibi ipamọ ati Itoju

This product is an efficient and durable submersible electric pump, suitable for a variety of environments and applications.In order to ensure the long-term use and stable performance of the product, we suggest that users pay special attention to drying the water in the motor cavity in winter to avoid freezing; in addition, the cable is coiled and tied, and properly stored in an environment without corrosive substances and gases, with a temperature below 40 °C. If the product is not used for a long time, attention should be paid to rust prevention treatment to ensure the life cycle and performance of the product.Whether for industrial use or for home use, this submersible electric pump can provide you with reliable pump service.

 

 
Wọ Awọn ẹya
    • Impeller
    • Ọwọ ọpa
    • Roba ọpa apo
    •  Iwọn edidi

 
Awọn oju iṣẹlẹ elo

01 Gbigbe omi kanga ti o jinlẹ

02 Giga-jinde omi ipese

03 oke omi ipese 

04 omi ẹṣọ

05 Ogbin irigeson

06 irigeson ọgba

07 odo omi gbigbemi

08 omi inu ile

 

Ti o ba nifẹ si awọn ọja wa, o le yan lati fi alaye rẹ silẹ nibi, ati pe a yoo kan si ọ laipẹ.


Kọ ifiranṣẹ rẹ nibi ki o si fi si wa

Ti o ba nifẹ si awọn ọja wa, o le yan lati fi alaye rẹ silẹ nibi, ati pe a yoo kan si ọ laipẹ.


yoYoruba